<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/api-661/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #API 661</title><description>BTGC - Knowledge Hub #API 661</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/api-661</link><lastBuildDate>Wed, 18 Nov 2026 11:16:13 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Air-Cooled Heat Exchangers to API 661 for Saudi Refineries]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/api-661-air-cooled-heat-exchangers-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/hemaco-shell-and-tube-heat-exchanger-tube-bundle.webp"/>What API 661 requires for air coolers, Saudi supplementary requirements, forced versus induced draft and alloys. Hemaco air-cooled exchangers from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_cG6h0ot6Ts-_3PD9Zo_Vow" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_RpwH3o4BTWKCCqHjBJfn6w" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_fnxL7bHxQ_6OfTmU1Yp2Xw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_XpCm5clGepEJVrhviyx2hQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> API 661 is the standard that turns an air cooler from a fan and some finned tubes into a piece of refinery equipment: it fixes the design margins, the header and tube construction, the fan and drive requirements and the inspection and testing. Hemaco builds air-cooled heat exchangers to API 661 and ASME in Italy, and BTGC is its partner in Saudi Arabia for refineries, gas plants and petrochemical units.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/hemaco-shell-and-tube-heat-exchanger-tube-bundle.webp" alt="Shell-and-tube heat exchanger tube bundle in the Hemaco workshop" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Saudi Aramco, SABIC and the EPC contractors who build for them specify air coolers to API 661 (ISO 13706), usually with their own supplementary requirements on top. A buyer who understands what the standard asks for can read a vendor's proposal properly, and a vendor who builds to it routinely saves the project months of inspection arguments.</p><h2>What API 661 covers</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Area</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Key requirements</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Thermal design</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Design air temperature, fouling factors, fan power margin, minimum face velocity, no credit for wind</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Tube bundles</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Minimum tube wall, fin types and temperature limits, tube-to-header joint, bundle rigidity</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Headers</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Plug, cover plate or manifold type by pressure and fouling; plug and gasket materials; ASME VIII design</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Fans and drives</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Fan tip speed limits, blade pitch, belt or gear drives, vibration switches, motor sizing at minimum air temperature</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Structure</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Plenum and support design, access platforms, wind and seismic loads, hot-dip galvanising</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Inspection and testing</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Hydrotest, fan performance, shop run test, documentation and data sheets</td></tr></tbody></table><h2>Saudi supplementary requirements</h2><p>The operator's standards add to API 661 in predictable places: a design air temperature of 46 to 50 &deg;C, galvanising and coating systems for the coastal atmosphere, sand and dust provisions, specific fan and motor makes, and material requirements for sour service (NACE MR0175 / ISO 15156) where wet H2S is present. A fabricator used to working with operator supplements makes the difference between a smooth document review and a long one, so ask for the reference list with the offer.</p><h2>Forced or induced draft?</h2><p>Forced draft units put the fans below the bundle: easier maintenance, lower cost, but the hot air leaves slowly and can recirculate. Induced draft units put the fans above: better air distribution, higher stack velocity and less recirculation, at the price of fan components in hot air. For Saudi sites with large banks of coolers and a hot-air recirculation risk, induced draft is often preferred; for small or isolated units forced draft is common. API 661 allows both and the choice is made in the data sheet.</p><h2>Special alloys and difficult services</h2><p>Hemaco's strength is in exchangers that are not catalogue items: air coolers with duplex, super duplex or titanium tubes for sour and chloride services, high-pressure header boxes for hydrotreater effluent, and combined packages with the shell and tube exchangers and pressure vessels described in the earlier article on <a href="https://www.btc-ksa.com/Knowledge-Hub/post/shell-and-tube-heat-exchanger-alloys-saudi-arabia">exchangers in special alloys</a>.</p><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/kelvion-rooftop-air-cooled-heat-exchanger-units.webp" alt="Air-cooled heat exchanger units with axial fans" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Hemaco from BTGC</h2><p>Hemaco S.r.l., Italy, designs and fabricates shell and tube heat exchangers, air-cooled heat exchangers and pressure vessels to ASME, TEMA and API 661, with U-stamp and the material certifications Saudi projects require. BTGC is the <a href="https://www.btc-ksa.com/hemaco-saudi-arabia">Hemaco partner in Saudi Arabia</a>, coordinating enquiries, engineering clarifications, inspection visits, shipping and site support. See the <a href="https://www.btc-ksa.com/process-separation">process and thermal</a> page and the <a href="https://www.btc-ksa.com/oil-gas">oil and gas sector page</a>.</p><h2>Questions buyers ask</h2><p><strong>What documents come with an API 661 unit?</strong> Data sheets, thermal and mechanical calculations, drawings, material certificates, weld procedures, NDT reports, hydrotest and fan test reports and the ASME data report.</p><p><strong>Can Hemaco supply replacement bundles for existing coolers?</strong> Yes, to the original data sheet or an uprated design, in the original or an improved material.</p><p><strong>What delivery time should we plan?</strong> Typically 6 to 9 months for a full unit, less for bundles; BTGC tracks the schedule with the factory.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Sun, 15 Nov 2026 08:36:43 +0300</pubDate></item><item><title><![CDATA[Air Fin Coolers Where Water Is Scarce: Saudi Design Points]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/air-fin-coolers-air-cooled-heat-exchangers-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/kelvion-rooftop-air-cooled-heat-exchanger-units.webp"/>Designing air-cooled heat exchangers for 50 degree air, dust and recirculation, and when hybrids make sense. Kelvion air fin coolers to API 661 from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_YOsPI3EFSLC8sBY67JXeVQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_Lq2JlPBQQx69snQXQoz91Q" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_I5ZHIvjBQvCcaPSiPhN9AA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_elen6uMzHOfTVLkLaqurEw" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> an air fin cooler rejects process heat to the air instead of to water, so it needs no cooling water, no water treatment and no blowdown. The price is a larger footprint and a design that must work at a 50 &deg;C summer air temperature. BTGC supplies Kelvion air-cooled heat exchangers to API 661 for Saudi refineries, gas plants and petrochemical units, and supports bundles, fans and spares locally.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/kelvion-rooftop-air-cooled-heat-exchanger-units.webp" alt="Rooftop air-cooled heat exchanger units with axial fans" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Water is the scarcest utility in the Kingdom. Coastal plants have seawater, but inland gas plants, pipeline compressor stations, mining sites and the new industrial zones away from the coast do not, and even coastal plants pay for every cubic metre of make-up water a cooling tower evaporates. The air fin cooler is how a process plant rejects heat without water, and it is the standard choice for overhead condensers, compressor intercoolers, lube oil coolers and product rundown coolers across Saudi oil and gas.</p><h2>How an air-cooled heat exchanger works</h2><p>The process fluid flows inside finned tubes arranged in bundles; axial fans push (forced draft) or pull (induced draft) ambient air across the fins. The fins multiply the air-side surface area by ten to twenty times, which compensates for air being a far poorer coolant than water. The unit is sized for the design air temperature, and that is where Saudi projects differ from most of the world.</p><h2>Design points for the Gulf</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Issue</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Design response</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Design air temperature of 46 to 50 &deg;C</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Larger surface, more bays; process outlet temperatures above 60 &deg;C are realistic, lower ones need trim cooling</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Hot air recirculation</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Induced draft with tall stacks, bay spacing and plot layout studied by CFD on large installations</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Dust and sand</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Wider fin pitch, embedded or extruded fins that resist cleaning damage, access for washing</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Winter performance</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Variable speed or auto-variable pitch fans, louvres where pour point or hydrate formation matters</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Corrosive atmosphere</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Aluminium fins with galvanised or coated tubes; stainless or duplex tubes where the process demands</td></tr></tbody></table><h2>Fin types and when they matter</h2><p>API 661 recognises several fin constructions: L-footed and overlapped L fins for temperatures to about 130 &deg;C, embedded (G) fins to 400 &deg;C and beyond, and extruded fins that give the best corrosion protection and mechanical strength. Saudi plants with sand cleaning and high tube-wall temperatures tend toward embedded or extruded fins; the slightly higher cost is paid back in fin life.</p><h2>Water-saving hybrids</h2><p>Where an air cooler cannot reach the required outlet temperature on the hottest days, two options avoid a full wet cooling system: a small trim cooler on cooling water for the last few degrees, or an adiabatic pre-cooling pad that wets the inlet air only during peak hours. Kelvion offers both approaches within its air cooler and dry cooler ranges, and the same thinking is applied to utility cooling by <a href="https://www.btc-ksa.com/baltimore-aircoil-saudi-arabia">Baltimore Aircoil</a> adiabatic coolers.</p><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/hemaco-shell-and-tube-heat-exchanger-tube-bundle.webp" alt="Shell and tube heat exchanger tube bundle" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Kelvion from BTGC</h2><p>Kelvion Holding GmbH, Germany, formerly GEA Heat Exchangers, designs and manufactures air-cooled heat exchangers to API 661 and ISO 13706, dry coolers, plate heat exchangers and shell and tube units. BTGC is the <a href="https://www.btc-ksa.com/kelvion-saudi-arabia">Kelvion partner in Saudi Arabia</a> for new units, replacement bundles, fans, drives and spares, with site support from Dammam, Jubail and Yanbu. See the earlier article on <a href="https://www.btc-ksa.com/Knowledge-Hub/post/plate-vs-shell-and-tube-heat-exchanger-saudi-arabia">choosing between plate and shell and tube exchangers</a>, the <a href="https://www.btc-ksa.com/process-separation">process and thermal</a> page and the <a href="https://www.btc-ksa.com/oil-gas">oil and gas sector page</a>.</p><h2>Questions buyers ask</h2><p><strong>What information does a quotation need?</strong> Process fluid, flow, inlet and outlet temperatures, allowable pressure drop, design pressure and temperature, site design air temperature and the plot space available.</p><p><strong>Can an existing air cooler be uprated?</strong> Often yes: new bundles with better fins, larger or variable speed fans and adiabatic pads can add 10 to 25 per cent capacity.</p><p><strong>Do you supply replacement bundles for other makers' units?</strong> Yes, built to the original data sheet and API 661.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Sun, 15 Nov 2026 08:33:27 +0300</pubDate></item></channel></rss>