<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/bimetal-thermometers/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #bimetal thermometers</title><description>BTGC - Knowledge Hub #bimetal thermometers</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/bimetal-thermometers</link><lastBuildDate>Wed, 18 Nov 2026 11:17:29 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Bimetal and Gas-Filled Thermometers: Selection and Installation]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/bimetal-gas-filled-thermometers-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/nuova-fima-pressure-gauges-diaphragm-seals.webp"/>When to use bimetal or gas-filled dial thermometers, ranges, accuracy, capillaries, thermowells and installation tips for process plants. Nuova Fima, BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_46oPumwcQtGXZtQX3tzBBA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_JidODK1sSCWrZ6tfgIW-Fw" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_uG1i-tLuQnyd5vibnBv0Nw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_MXefUDQtnZXlNguAakqvbA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> dial thermometers give operators a local reading without power. Bimetal thermometers use a coiled strip of two metals that twists with temperature, and suit direct mounting on pipes and vessels. Gas-filled thermometers use a sealed bulb and capillary, so the dial can sit a few metres away, and they handle vibration and wider ranges well. Both normally sit in a thermowell. BTGC supplies Nuova Fima thermometers and thermowells.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/nuova-fima-pressure-gauges-diaphragm-seals.webp" alt="Nuova Fima gauges and instruments" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Pumps, exchangers, tanks and utility lines in Saudi plants all carry local temperature gauges for operator rounds.</p><h2>Bimetal or gas-filled</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Feature</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Bimetal</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Gas-filled</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Principle</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Twisting bimetal coil</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Gas pressure in a sealed bulb</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Remote mounting</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">No, dial on the stem</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Yes, through a capillary</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Vibration</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Liquid-filled cases help</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Generally good</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Response</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Slower</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Faster with a suitable bulb</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Typical use</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Pipes, tanks, utility lines</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Machines, panels, hard-to-read points</td></tr></tbody></table><h2>Selection points</h2><ul><li><p>Choose a range so normal operation sits in the middle of the scale.</p></li><li><p>Match stem or bulb length to the thermowell and insertion depth; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/thermowells-temperature-measurement-saudi-arabia">thermowells</a>.</p></li><li><p>Use stainless steel cases and suitable windows for outdoor and corrosive areas.</p></li><li><p>Choose every-angle or back-connected designs so dials face the operator.</p></li><li><p>Add liquid filling where vibration makes pointers hard to read; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/pressure-gauges-vibration-pulsation-diaphragm-seals-saudi-arabia">gauges under vibration</a>.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/process-piping-petrochemical-plant.webp" alt="Process piping with local instruments" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Installation and checks</h2><ul><li><p>Always fit in a thermowell on pressurised lines, so the instrument can be removed safely.</p></li><li><p>Protect capillaries from kinks and mechanical damage.</p></li><li><p>Keep direct sun off dials where possible; it can affect readings and windows.</p></li><li><p>Check thermometers against a reference during calibration rounds; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/pressure-gauge-transmitter-calibration-saudi-arabia">calibration</a>.</p></li></ul><h2>Nuova Fima from BTGC</h2><p>Nuova Fima makes pressure gauges, bimetal and gas-filled thermometers, thermowells, diaphragm seals and switches. BTGC supplies <a href="https://www.btc-ksa.com/Knowledge-Hub/post/nuova-fima-saudi-arabia">Nuova Fima in Saudi Arabia</a> for projects and maintenance contracts. See also the <a href="https://www.btc-ksa.com/petrochemicals">petrochemicals sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>How accurate are dial thermometers?</strong> Typically around 1% of span, depending on type and class; check the data sheet.</p><p><strong>Can a bimetal thermometer be used without a thermowell?</strong> Only on unpressurised or low-risk points; process lines need a thermowell.</p><p><strong>Does BTGC supply matched thermowells?</strong> Yes, thermowells sized to the thermometer and process.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 14:26:15 +0300</pubDate></item><item><title><![CDATA[Thermowells and Temperature Measurement in Process Plants]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/thermowells-temperature-measurement-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/nuova-fima-pressure-gauges-diaphragm-seals.webp"/>How to choose thermometers and thermowells for process plants, check thermowells for flow-induced vibration and get accurate, fast readings. Nuova Fima, BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_oqWGiGoTTjWXuE9HKqnHmA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_SJaxGM4cQ8qeJmQoHRF40A" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_ykJyhCJhQJmPfx2w8t7Ydw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_I688seIievUXPxoZfKJYbA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> temperature is measured at thousands of points in a process plant, by local thermometers and by sensors linked to the control system. Most sit inside thermowells that protect them from pressure, corrosion and flow. A badly designed thermowell can break from flow-induced vibration and release process fluid, so thermowells are checked with the ASME PTC 19.3 TW method. Choosing the right instrument, insertion length and thermowell shape gives safe, accurate and responsive readings. BTGC supplies Nuova Fima thermometers, thermowells and gauges.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/nuova-fima-pressure-gauges-diaphragm-seals.webp" alt="Nuova Fima gauges and thermometers" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Refineries, petrochemical plants, gas plants and power stations in the Kingdom rely on temperature readings for control, safety and energy efficiency. Thermowell failures have caused serious leaks worldwide, which is why their design is now checked more carefully.</p><h2>Instrument options</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Instrument</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Typical use</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Bimetal dial thermometer</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Local reading on pipes and vessels, robust and simple</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Gas or liquid-filled thermometer</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Local or remote reading with capillary, vibration-resistant</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">RTD (Pt100)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Accurate measurement for control systems</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Thermocouple</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">High temperatures and fast response</td></tr></tbody></table><h2>Thermowell design points</h2><ul><li><p>Check every thermowell in flowing fluid with the ASME PTC 19.3 TW calculation for vortex shedding frequency and stress.</p></li><li><p>Limit unsupported length; long, thin wells in high-velocity gas are most at risk.</p></li><li><p>Choose tapered or stepped shanks and suitable materials for strength and corrosion; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/valve-body-materials-selection-saudi-arabia">material selection</a>.</p></li><li><p>Make insertion long enough for accurate reading, often reaching about the middle third of the pipe, without overstressing the well.</p></li><li><p>Specify process connection, pressure rating and testing to match the piping class.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/chemical-reactor-petrochemical-plant.webp" alt="Chemical reactor in a process plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Accuracy and maintenance</h2><ul><li><p>Use spring-loaded sensors that touch the bottom of the well, and heat-transfer paste where suitable, for fast response.</p></li><li><p>Calibrate thermometers and sensors against references at set intervals.</p></li><li><p>Compare local and remote readings during rounds to spot drift.</p></li><li><p>Inspect thermowells for erosion and corrosion at turnarounds.</p></li><li><p>Replace instruments with fogged dials, sticking pointers or broken glass promptly.</p></li></ul><h2>Nuova Fima from BTGC</h2><p>Nuova Fima of Italy makes pressure gauges, thermometers, thermowells, diaphragm seals, transmitters and switches for oil and gas, petrochemical and power plants. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/nuova-fima-saudi-arabia">Nuova Fima partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/pressure-gauges-vibration-pulsation-diaphragm-seals-saudi-arabia">pressure gauges under vibration</a> and the <a href="https://www.btc-ksa.com/petrochemicals">petrochemicals sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Why do thermowells break?</strong> Flow past the well sheds vortices; if their frequency is near the well's natural frequency, it can resonate and crack.</p><p><strong>Bimetal or filled thermometer?</strong> Bimetal thermometers are simple and robust; filled systems allow remote mounting and resist vibration better.</p><p><strong>Can BTGC supply thermowells with calculations?</strong> Yes, Nuova Fima thermowells can be supplied with wake frequency calculations.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 12:39:45 +0300</pubDate></item></channel></rss>