<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/calibration/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #calibration</title><description>BTGC - Knowledge Hub #calibration</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/calibration</link><lastBuildDate>Wed, 18 Nov 2026 05:30:40 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Calibrating Pressure Gauges and Transmitters: Intervals, Methods and Records]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/pressure-gauge-transmitter-calibration-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/nuova-fima-pressure-gauges-diaphragm-seals.webp"/>How to calibrate pressure gauges and transmitters: reference standards, test points, as-found and as-left data, intervals and records. Nuova Fima from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_nZkKsT-xTMWl5sGKfV_KfQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_I45_yjPyQQ6_Z4v6d5zQsg" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_v2htBiUbQom7KYz5B3eC8w" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_Bx5hZb5AGhtJ094nSb0mVQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> pressure gauges and transmitters drift over time because of vibration, pulsation, heat and overpressure. Calibration compares them with a more accurate, traceable reference at several points, records how far off they were and adjusts or replaces them. Setting intervals from criticality and drift history, and keeping good records, turns calibration from a routine chore into a source of reliability data. BTGC supplies Nuova Fima pressure gauges, transmitters and diaphragm seals.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/nuova-fima-pressure-gauges-diaphragm-seals.webp" alt="Nuova Fima pressure gauges and diaphragm seals" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Plants in the Kingdom run thousands of pressure instruments, many in hot outdoor locations and on vibrating equipment. Wrong readings can hide process problems or trigger false trips.</p><h2>Calibration basics</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Step</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">What it involves</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Reference standard</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Deadweight tester or calibrator, traceable to accredited labs</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Test points</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Several points across the range, rising and falling</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">As-found data</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Readings before any adjustment, showing drift</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Adjustment</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Zero and span for transmitters, or repair or replacement for gauges</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">As-left data</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Readings after adjustment, within tolerance</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Records and labels</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Date, results, next due date and technician</td></tr></tbody></table><h2>Setting intervals</h2><ul><li><p>Start from the manufacturer guidance and the instrument accuracy class.</p></li><li><p>Shorten intervals for safety, custody transfer and critical control loops.</p></li><li><p>Lengthen intervals for stable instruments with good as-found history.</p></li><li><p>Follow proof test intervals for instruments in safety instrumented functions.</p></li><li><p>Review intervals every year using the drift data.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/chemical-reactor-petrochemical-plant.webp" alt="Petrochemical plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Practical tips</h2><ul><li><p>Check for damage, blocked impulse lines and failed diaphragm seals before calibrating.</p></li><li><p>Calibrate at the mounting position or correct for head where it matters.</p></li><li><p>Replace gauges with bent pointers or zero offset after overpressure.</p></li><li><p>Use dampening or diaphragm seals where vibration and pulsation cause drift; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/pressure-gauges-vibration-pulsation-diaphragm-seals-saudi-arabia">gauges for vibration and pulsation</a>.</p></li><li><p>Store calibration data where reliability engineers can trend it.</p></li></ul><h2>Nuova Fima from BTGC</h2><p>Nuova Fima of Italy makes pressure gauges, transmitters, switches, thermometers and diaphragm seals for oil and gas, petrochemical and power plants. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/nuova-fima-saudi-arabia">Nuova Fima partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/pressure-transmitters-selection-installation-saudi-arabia">pressure transmitter selection</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/thermowells-temperature-measurement-saudi-arabia">thermowells</a> and the <a href="https://www.btc-ksa.com/petrochemicals">petrochemicals sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>How often should pressure gauges be calibrated?</strong> It depends on criticality and history; many plants use 6 to 24 months.</p><p><strong>What does as-found data show?</strong> How much the instrument drifted since the last calibration.</p><p><strong>Does BTGC supply replacement gauges?</strong> Yes, Nuova Fima gauges, transmitters and diaphragm seals.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 07:31:47 +0300</pubDate></item><item><title><![CDATA[Pressure Transmitters in Process Plants: Selection, Installation and Calibration]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/pressure-transmitters-selection-installation-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/nuova-fima-pressure-gauges-diaphragm-seals.webp"/>How to choose and install pressure and differential pressure transmitters, use remote seals, and keep readings accurate in hot plants. Nuova Fima from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_y3bUTZ8fTXqm5B8w-Wcq7Q" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_sv-JsPu2QFOYQmoG_Ibb_Q" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_1YpO3zWzRBiJEzmNGesYCg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_hpG2wS4a1NCWvj_6e-nfqQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> pressure and differential pressure transmitters send the readings that control systems use for pressure, flow and level control and for safety trips. A transmitter is only as good as its installation: impulse lines that block or freeze, remote seals with the wrong fill fluid, and hot sun on the housing all cause errors. Choosing the right range, materials and connection, installing correctly and calibrating regularly keeps measurements trustworthy. BTGC supplies Nuova Fima transmitters, gauges and diaphragm seals.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/nuova-fima-pressure-gauges-diaphragm-seals.webp" alt="Nuova Fima pressure instruments" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Every unit in a refinery, gas plant or power station depends on hundreds of transmitters. Errors and blocked lines lead to poor control and spurious trips.</p><h2>Selection points</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Item</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">What to consider</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Measurement</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Gauge, absolute or differential pressure</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Range and turndown</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Normal value in the useful part of the range</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Wetted materials</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Suited to the fluid and to sour service if needed</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Connection</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Direct, with manifold, or with remote diaphragm seals</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Approvals</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Hazardous area certification and safety ratings for trip duties</td></tr></tbody></table><h2>Installation good practice</h2><ul><li><p>Keep impulse lines short, sloped correctly and free of pockets.</p></li><li><p>Mount transmitters below the tap for liquids and above for gas, unless seals are used.</p></li><li><p>Use remote diaphragm seals for viscous, corrosive, hot or plugging fluids; choose fill fluids for the temperature range; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/pressure-gauges-vibration-pulsation-diaphragm-seals-saudi-arabia">diaphragm seals</a>.</p></li><li><p>Shade transmitters and capillaries from direct sun to limit temperature errors.</p></li><li><p>Use manifolds for safe isolation, venting and calibration.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/process-piping-petrochemical-plant.webp" alt="Process piping" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Calibration and checks</h2><ul><li><p>Calibrate on a schedule set by criticality and drift history.</p></li><li><p>Check zero regularly on differential pressure transmitters.</p></li><li><p>Blow down or flush impulse lines on dirty services.</p></li><li><p>Compare transmitters with local gauges during rounds.</p></li><li><p>Record drift to adjust calibration intervals.</p></li></ul><h2>Nuova Fima from BTGC</h2><p>Nuova Fima of Italy makes pressure gauges, transmitters, switches, thermometers and diaphragm seals for oil and gas, petrochemical and power plants. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/nuova-fima-saudi-arabia">Nuova Fima partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/thermowells-temperature-measurement-saudi-arabia">thermowells and temperature measurement</a> and the <a href="https://www.btc-ksa.com/petrochemicals">petrochemicals sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>When are remote diaphragm seals needed?</strong> For fluids that are corrosive, viscous, hot, crystallising or that would block impulse lines.</p><p><strong>Why does sunshine affect readings?</strong> Heating changes the fill fluid volume in seals and capillaries and affects electronics, causing errors.</p><p><strong>Does BTGC supply calibrated transmitters?</strong> Yes, with factory calibration certificates.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 15:16:17 +0300</pubDate></item><item><title><![CDATA[Calibrating Roll Force and Strip Tension Systems in Rolling Mills]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/rolling-mill-load-cell-calibration-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/kelk-roll-force-measurement-system-rolling-mill.webp"/>Why roll force load cells and tensiometers drift, how mills calibrate them and what a good maintenance routine looks like. Kelk measurement systems from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_Mv_K4DbRRlKO3m5UqxIFDg" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_lD_ECxrcRNiFUhj6VMs2gQ" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_HvfQvaKZR6G090dXpGm4LQ" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_r_Hv2Or6KZ2DEK0UScNiMQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> gauge control, mill setup models and strip tension loops all trust the numbers from the load cells under the rolls. When those numbers drift, the mill corrects in the wrong direction: off-gauge heads and tails, poor flatness, strip breaks and mill stretch errors. Routine checks of zero, side-to-side balance and cabling, and a full calibration at planned shutdowns, keep the measurements honest. BTGC supplies Kelk roll force and tension systems and supports calibration for Saudi steel and aluminium mills.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/kelk-roll-force-measurement-system-rolling-mill.webp" alt="Kelk roll force measurement system for rolling mills" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Roll force load cells sit in one of the harshest places in a plant: under the screwdown or hydraulic cylinder, carrying millions of load cycles, flooded with roll coolant, emulsion or scale, and exposed to heat from the strip. Tensiometer load cells under deflector rolls face similar conditions. They are built for it, but no measurement stays accurate for ever without checks.</p><h2>Why mill measurements drift</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Cause</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Effect on the reading</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Water or coolant in the cell or connector</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Unstable zero, noise, insulation faults</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Damaged or crushed cables</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Intermittent signals, offset changes</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Uneven seating or a distorted bearing block</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Load shared unevenly; wrong force reading on one side</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Overload or impact from cobbles and strip breaks</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Permanent zero shift</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Temperature changes</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Zero drift if the cell or electronics are not compensated</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Electronics ageing</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Gain and offset errors in the amplifier or transmitter</td></tr></tbody></table><h2>Routine checks between shutdowns</h2><ul><li><p><strong>Zero check.</strong> Record the reading with the mill open and unloaded at the same point in every shift or roll change, and trend it: a slow change shows a developing fault.</p></li><li><p><strong>Side-to-side comparison.</strong> Operator side and drive side cells should read alike on a centred, flat strip. A growing difference points to a cell, cable or mechanical problem.</p></li><li><p><strong>Cross-check against hydraulics.</strong> On hydraulic gap control mills, compare load cell force with the force calculated from cylinder pressure; a divergence flags one of the two.</p></li><li><p><strong>Insulation and cable tests.</strong> Measure insulation resistance of cells and cables at roll changes and inspect cable routes for damage.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/kelk-rolling-mill-sensors-range.webp" alt="Kelk rolling mill sensors: load cells, tensiometers and gauges" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Calibration at planned shutdowns</h2><p>Roll force systems are calibrated with a reference load in the mill window, typically a calibrated reference load cell or calibration jack placed in the stand, with the mill's own cylinders applying load in steps up to the working range and back down. Each step is compared and the gain is set. Tensiometers are calibrated with known weights hung on a sling over the roll at the design wrap angle, or with a calibrated force applied along the strip path. The records, with zero and span before and after, are the evidence the quality system needs.</p><h2>Mill stretch and gauge control</h2><p>Load cell force also feeds the mill stretch calculation: the stand stretches in proportion to force, and the gauge control system uses that to correct the roll gap. A force error of a few per cent becomes a thickness error the gauge meter cannot see. That is why roll force calibration belongs in the commissioning of any new gauge control model, together with the speed measurement described in <a href="https://www.btc-ksa.com/Knowledge-Hub/post/laser-velocimeter-hot-strip-mill-saudi-arabia">laser velocimeters</a>.</p><h2>Spares and repair</h2><ul><li><p>Keep at least one spare cell for each critical position, stored dry with protective caps.</p></li><li><p>Replace connectors and cable sections with the manufacturer's parts to keep sealing and shielding intact.</p></li><li><p>Send suspect cells for test and recalibration rather than re-zeroing them in the mill and hiding a fault.</p></li></ul><h2>Kelk from BTGC</h2><p>Kelk, part of Vishay Precision Group, builds ROLLMAX roll force systems, TENSIOMETER strip tension systems, laser velocimeters and other measurement equipment for rolling mills. BTGC is the <a href="https://www.btc-ksa.com/kelk-saudi-arabia">Kelk partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/roll-force-load-cells-rolling-mill-saudi-arabia">roll force load cells</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/strip-tension-measurement-tensiometers-saudi-arabia">strip tension measurement</a> and the <a href="https://www.btc-ksa.com/metal-sector">metals and steel sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>How often should roll force cells be calibrated?</strong> Typically at each major shutdown, with zero and side-to-side checks every shift or roll change; the trend decides whether more frequent calibration is needed.</p><p><strong>Can a cell damaged by a cobble be repaired?</strong> It must be tested first; a permanent zero shift or an insulation fault usually means replacement or factory repair.</p><p><strong>Can BTGC support a calibration during our shutdown?</strong> Yes. BTGC coordinates calibration equipment and support with Kelk; book early so it fits the shutdown plan.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Mon, 16 Nov 2026 09:57:12 +0300</pubDate></item></channel></rss>