<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/chlorine/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #chlorine</title><description>BTGC - Knowledge Hub #chlorine</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/chlorine</link><lastBuildDate>Wed, 18 Nov 2026 07:11:11 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Valves for Chlorine, Hydrochloric Acid and Chlor-Alkali Plants]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/valves-chlorine-hydrochloric-acid-chlor-alkali-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/crane-lined-valves-range.webp"/>Choosing valves for wet and dry chlorine, HCl, caustic soda and brine: lined, sleeved plug and diaphragm valves. Crane ChemPharma and Energy valves from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_TUutCNOyTB-WrKF3-wITUA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_OayCgBCMRtmsvWstMrnMqg" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_ol80yAq3Shy08pRQtKfxWg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_BDuwUw3uLERLMniAvOv9xA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> a chlor-alkali, EDC/VCM or water treatment plant handles some of the most aggressive fluids in industry: wet and dry chlorine, hydrochloric acid, hot caustic soda, brine and sodium hypochlorite. No single valve material suits them all. Dry chlorine is handled in steel and alloy valves under strict cleanliness rules; wet chlorine, HCl and hypochlorite call for fluoropolymer-lined valves; caustic and brine have their own choices. BTGC supplies Crane ChemPharma &amp; Energy lined, sleeved plug and diaphragm valves for these services.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/crane-lined-valves-range.webp" alt="Crane ChemPharma and Energy lined valve range" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Saudi Arabia's chlor-alkali, PVC and water treatment plants depend on valves that handle chlorine chemistry for years without leaking. A leak here is not just lost product: chlorine is toxic at low concentrations, and HCl vapour corrodes everything around the valve. Valve selection therefore starts from the exact phase, moisture content and temperature of each stream on the line list.</p><h2>Wet or dry chlorine changes everything</h2><p>Dry chlorine, with its moisture held below the limit the plant specifies, is not very corrosive to carbon steel at normal temperatures, which is why dry chlorine systems use steel piping and valves designed and cleaned to the Chlorine Institute's guidance, such as Pamphlet 6 for piping systems. At high temperature, around 250 &deg;C, steel can ignite in chlorine, so hot spots must be avoided. Once moisture enters, chlorine forms hydrochloric and hypochlorous acids and attacks steel rapidly. Wet chlorine from the cell room, before drying, is therefore handled in titanium, fibre-reinforced plastic or fluoropolymer-lined equipment. A valve chosen for dry chlorine can fail quickly if the drying system upsets.</p><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Stream</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Main concern</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Typical valve choices</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Dry chlorine gas and liquid</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Cleanliness, moisture ingress, stem leakage, trapped liquid expansion</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Steel or alloy valves cleaned and dried for chlorine service, extended bonnets and cavity relief for liquid; sleeved plug valves; enhanced stem seals</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Wet chlorine gas</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Severe corrosion of steel</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Fluoropolymer-lined valves, titanium valves</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Hydrochloric acid</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">General corrosion of most metals</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">PTFE or PFA-lined plug, ball and butterfly valves; lined diaphragm valves</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Sodium hypochlorite</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Oxidising; attacks many metals and some elastomers</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Lined valves with compatible linings and seals</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Caustic soda</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Caustic stress corrosion cracking at high temperature and concentration</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Nickel alloy or lined valves in hot concentrated service; carbon steel only within the caustic service limits</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Brine</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Chloride pitting, crystallisation</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Lined or rubber-lined valves, diaphragm valves</td></tr></tbody></table><h2>Why lined and sleeved valves suit acid service</h2><p>A PTFE or PFA lining isolates the metal body from the fluid, and fluoropolymers resist almost all the chemicals in a chlor-alkali plant. Sleeved plug valves, such as the Xomox design, add a full PTFE sleeve between plug and body, giving a seal with no cavities for solids or crystals to collect. Diaphragm valves, such as Saunders, keep the operating mechanism completely outside the fluid. For the general design rules of lined valves, see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/lined-valves-acid-service-saudi-arabia">lined valves for acid service</a> and <a href="https://www.btc-ksa.com/Knowledge-Hub/post/sleeved-plug-diaphragm-valves-polymers-slurry-saudi-arabia">sleeved plug and diaphragm valves</a>.</p><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/ptfe-lined-butterfly-valve-acid-service.webp" alt="PTFE/PFA-lined butterfly valve for acid service" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Details that decide reliability</h2><ul><li><p><strong>Permeation.</strong> Chlorine and HCl can permeate thin fluoropolymer linings at high temperature. Thicker linings, vent features in the body and the right lining grade reduce the effect.</p></li><li><p><strong>Vacuum rating.</strong> Lined valves must be rated for vacuum if the line can pull one, or the lining can collapse.</p></li><li><p><strong>Stem sealing.</strong> Toxic service usually calls for enhanced stem seals and leak detection; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/fire-safe-low-emission-valves-api-607-iso-15848-saudi-arabia">fire-safe and low-emission valves</a>.</p></li><li><p><strong>Cleaning for dry chlorine.</strong> Valves for dry chlorine are degreased, dried and sealed at the factory; any oil or water left inside can react with chlorine.</p></li><li><p><strong>Documentation.</strong> Each lined valve should arrive with lining spark test records and material certificates.</p></li></ul><h2>Crane ChemPharma &amp; Energy from BTGC</h2><p>Crane ChemPharma &amp; Energy brings together Xomox sleeved plug valves, Saunders diaphragm valves, PFA and PTFE-lined ball, plug, butterfly and check valves, and Crane process valves. BTGC is a <a href="https://www.btc-ksa.com/crane-saudi-arabia">Crane partner in Saudi Arabia</a>, with local assembly support in Dammam. See the <a href="https://www.btc-ksa.com/xomox-saudi-arabia">Xomox</a> and <a href="https://www.btc-ksa.com/saunders-saudi-arabia">Saunders</a> pages and the <a href="https://www.btc-ksa.com/petrochemicals">petrochemicals sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Can one valve type cover the whole chlor-alkali plant?</strong> No. Dry chlorine, wet chlorine, HCl and caustic need different materials; BTGC selects valves stream by stream from the line list.</p><p><strong>How long do lined valves last in HCl service?</strong> With the right lining and careful installation, many years. Failures usually come from permeation at high temperature, vacuum collapse or damage during installation.</p><p><strong>Do you supply valves cleaned for chlorine service?</strong> Yes. Valves can be ordered degreased, dried and sealed for dry chlorine service with the documentation the plant requires.</p><h2>Contact the BTGC valve team</h2><p>Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Mon, 16 Nov 2026 09:53:40 +0300</pubDate></item></channel></rss>