<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/class-vi/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #Class VI</title><description>BTGC - Knowledge Hub #Class VI</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/class-vi</link><lastBuildDate>Wed, 18 Nov 2026 04:44:20 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Control Valve Seat Leakage Classes: ANSI/FCI 70-2 Class II to VI]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-seat-leakage-classes-fci-70-2-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/koso-severe-service-control-butterfly-valves.webp"/>What control valve leakage classes II to VI mean, how they are tested, and when to ask for Class V or VI, with tips on trim and actuator thrust. KOSO, BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_3ma_6mhARJSQ7RXiB138dw" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_HGLfFUToTaawrrTq-Cji-w" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_yFPFI-XTSZ-9ghL0_61h-Q" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_GbxqoYEJXgyST3TNOnbucQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> control valves are built to regulate flow, not always to shut off tight, so their seat leakage is graded in classes defined by ANSI/FCI 70-2 (and IEC 60534-4). Class IV is common for metal seats, Class V for tight metal seats and Class VI for soft seats. Asking for a tighter class than needed adds cost and actuator size, while asking for too little can waste energy or erode trims. BTGC supplies KOSO control valves and tests valves at its Jubail service center.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/koso-severe-service-control-butterfly-valves.webp" alt="KOSO severe service control valves" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Process and power plants in the Kingdom specify control valve leakage on every data sheet, often without knowing what the class means in practice.</p><h2>The classes in brief</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Class</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Allowed leakage (summary)</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Typical seat</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">II</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">0.5% of rated capacity</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Metal, double-seated valves</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">III</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">0.1% of rated capacity</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Metal, balanced trims</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">IV</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">0.01% of rated capacity</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Metal seats, common default</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">V</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Very small water leakage per inch of port diameter per psi</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Tight metal seats, high thrust</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">VI</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Bubbles per minute of air, by port size</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Soft seats</td></tr></tbody></table><h2>Choosing the class</h2><ul><li><p>Use Class IV where the valve throttles and a separate block valve isolates.</p></li><li><p>Ask for Class V where leakage wastes high-pressure fluid, erodes the seat or affects safety, such as boiler feedwater and high-pressure drop duties.</p></li><li><p>Use Class VI soft seats only within their temperature and media limits.</p></li><li><p>Remember that tighter classes need more actuator thrust to seat the plug.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/valve-test-bench-btgc-service-center-jubail.webp" alt="Valve test bench at the BTGC Jubail service center" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Testing and service</h2><ul><li><p>Seat leakage is tested at the factory and again after repairs, using the method in the standard.</p></li><li><p>Damaged trims leak more over time; plan overhauls before leakage harms the process; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-overhaul-rebuild-saudi-arabia">control valve overhaul</a>.</p></li><li><p>For isolation valves, different standards apply; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/valve-seat-leakage-classes-api-598-iso-5208-saudi-arabia">API 598 and ISO 5208</a>.</p></li><li><p>Review sizing when duty changes; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-sizing-cv-rangeability-saudi-arabia">control valve sizing</a>.</p></li></ul><h2>KOSO from BTGC</h2><p>Nihon KOSO makes control valves and actuators known for severe service trims. BTGC supplies <a href="https://www.btc-ksa.com/koso-saudi-arabia">KOSO in Saudi Arabia</a> with sizing support and spares, and tests valves at the <a href="https://www.btc-ksa.com/btgc-jubail-service-center">Jubail service center</a>.</p><h2>Questions buyers ask</h2><p><strong>Is Class VI always better?</strong> No; soft seats have temperature and erosion limits, and metal seats with Class V may suit hard duties better.</p><p><strong>Can a valve meet a tighter class after repair?</strong> Sometimes, with new trim and lapping; the actuator must still give enough thrust.</p><p><strong>Can BTGC test leakage on site valves?</strong> Valves can be tested at the BTGC Jubail service center.</p><h2>Contact the BTGC valve team</h2><p>Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 14:32:05 +0300</pubDate></item></channel></rss>