<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/combined-cycle/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #combined cycle</title><description>BTGC - Knowledge Hub #combined cycle</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/combined-cycle</link><lastBuildDate>Wed, 18 Nov 2026 04:49:28 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Steam Turbines for Waste Heat Recovery and Combined Cycle Plants]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/steam-turbines-waste-heat-recovery-combined-cycle-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/main-steam-line-gate-valves-power-plant-saudi-arabia.webp"/>How steam turbines turn waste heat into power: combined cycle steam turbines, process waste heat, extraction and admission, and design points. Fuji Electric.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_KxDW25VvTVuwD3GKIolG_g" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_HB6JL7DpSKSJvUuNUmweSg" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_WFk_73KwTayYJgM1r6wKVQ" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_mrnZE557LclWkgm55Qb8gA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> much of the fuel burned in gas turbines, furnaces and chemical plants leaves as hot exhaust or surplus steam. A heat recovery steam generator turns that heat into steam, and a steam turbine generator turns the steam into electricity, raising plant efficiency without burning more fuel. In a combined cycle plant the steam turbine typically makes about one third of the total output. BTGC supports Fuji Electric steam turbines and generators for power generation.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/main-steam-line-gate-valves-power-plant-saudi-arabia.webp" alt="Main steam piping in a power plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Power producers, refineries, sulphuric acid plants and industrial cities in the Kingdom look for every megawatt they can recover from existing heat.</p><h2>Where waste heat steam comes from</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Source</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Notes</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Gas turbine exhaust</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Heat recovery steam generators in combined cycle and cogeneration plants</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Sulphuric acid plants</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Heat from sulphur burning and conversion raises high-pressure steam</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Furnaces and kilns</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Waste heat boilers on flue gas</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Surplus process steam</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Can drive a turbine instead of a letdown valve; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/steam-pressure-reducing-valves-saudi-arabia">steam pressure reducing valves</a></td></tr></tbody></table><h2>Turbine design points</h2><ul><li><p>Steam conditions follow the heat source, so the turbine must run well at part load and sliding pressure.</p></li><li><p>Multi-pressure heat recovery boilers feed steam into the turbine through admission stages.</p></li><li><p>Extraction points supply process steam in cogeneration; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/steam-turbines-industrial-cogeneration-saudi-arabia">back-pressure or condensing turbines</a>.</p></li><li><p>Condensing turbines often exhaust to air-cooled condensers, whose back pressure rises in summer; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/air-cooled-condenser-fan-gear-drives-saudi-arabia">ACC fan drives</a>.</p></li><li><p>Good water chemistry and steam purity keep deposits off the blades.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/desalination-plant-saudi-arabia.webp" alt="Power and desalination plant in Saudi Arabia" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Planning a project</h2><ul><li><p>Measure the heat really available across seasons and plant loads.</p></li><li><p>Compare the value of the power with capital and maintenance costs.</p></li><li><p>Plan grid connection and protection together with the generator supply.</p></li><li><p>Plan inspections from the start; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/steam-turbine-overhaul-planning-saudi-arabia">overhaul planning</a>.</p></li></ul><h2>Fuji Electric from BTGC</h2><p>Fuji Electric's power generation business supplies steam turbines and generators for conventional, combined cycle and combined heat and power plants. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/fuji-electric-saudi-arabia">Fuji Electric partner in Saudi Arabia</a> for power generation equipment: enquiries, spare parts and after-sales service coordination. See also the <a href="https://www.btc-ksa.com/power-utilities">power and utilities sector</a> page and <a href="https://www.btc-ksa.com/mega-projects-epc">mega-projects and EPC</a>.</p><h2>Questions buyers ask</h2><p><strong>How much power can waste heat produce?</strong> It depends on gas flow and temperature; a feasibility study measures it.</p><p><strong>Is a heat recovery steam generator a boiler?</strong> Yes, a boiler heated by exhaust gas rather than its own burner, though some have supplementary firing.</p><p><strong>Does BTGC supply Fuji Electric turbines?</strong> BTGC handles enquiries, spare parts and after-sales coordination for Fuji Electric power generation equipment.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 13:15:59 +0300</pubDate></item><item><title><![CDATA[Steam Turbine Bypass Valves: HP and LP Bypass in Combined Cycle Plants]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/turbine-bypass-valves-hp-lp-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/koso-severe-service-control-butterfly-valves.webp"/>How HP and LP turbine bypass valves work in combined cycle and cogeneration plants, why they fail, and how to keep them tight and fast. KOSO valves from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_GECQm3z7QP2yZmyA9ZGw8w" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_54JD9UcSQ2WioWd7ZSZF1A" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_hiksPTNhR-KPga8NHF4psA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_4NWQS6D09GKwvxXETO5nMA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> turbine bypass valves let a combined cycle or cogeneration plant send steam around the steam turbine during start-up, shutdown, load rejection or a turbine trip. The HP bypass drops main steam to cold reheat conditions and the LP bypass dumps reheat steam to the condenser, both with water injection to cool the steam. They must open in seconds, control smoothly and shut tight, while facing severe pressure drops, thermal shock and noise. BTGC supplies KOSO severe service control valves, including bypass valves.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/koso-severe-service-control-butterfly-valves.webp" alt="KOSO severe service control valves" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Combined cycle and cogeneration plants in the Kingdom often cycle daily or run at changing loads in summer and winter. Bypass systems are used far more than designers expected, and leaking or slow bypass valves cost fuel and availability.</p><h2>HP and LP bypass at a glance</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Item</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">HP bypass</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">LP bypass</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Steam path</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Main steam to cold reheat</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Hot reheat to condenser</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Cooling water</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Feedwater spray</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Condensate spray</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Main duties</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Start-up, trip, pressure control</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Start-up, trip, condenser protection</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Key risks</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Thermal shock, seat erosion</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Noise, vibration, condenser overload</td></tr></tbody></table><h2>Why bypass valves fail</h2><ul><li><p>Very high pressure drops erode trim and seats, especially when valves throttle near closed.</p></li><li><p>Fast heating during trips causes thermal shock and cracking.</p></li><li><p>Spray water valves suffer cavitation; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/boiler-feedwater-spray-water-control-valves-saudi-arabia">spray water control valves</a>.</p></li><li><p>Seat leakage when closed wastes steam and heat rate.</p></li><li><p>Actuator and positioner problems slow the response during a trip.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/main-steam-line-gate-valves-power-plant-saudi-arabia.webp" alt="Main steam piping in a power plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Keeping bypass systems reliable</h2><ul><li><p>Specify multi-stage pressure-reducing trim and tight shutoff for the real operating range.</p></li><li><p>Check stroke time and fail action at every outage.</p></li><li><p>Monitor downstream temperature to detect seat leakage early.</p></li><li><p>Inspect desuperheater nozzles and spray valves for wear and blockage.</p></li><li><p>Plan trim and seat spares before major outages; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-overhaul-rebuild-saudi-arabia">control valve overhaul</a>.</p></li></ul><h2>KOSO from BTGC</h2><p>Nihon KOSO makes severe service control valves, actuators and positioners for power, oil and gas and process plants. BTGC is the <a href="https://www.btc-ksa.com/koso-saudi-arabia">KOSO partner in Saudi Arabia</a>, with valve testing and repair at the Jubail service center. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/steam-pressure-reducing-valves-saudi-arabia">steam pressure reducing valves</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-cavitation-noise-high-pressure-drop-saudi-arabia">cavitation and noise</a> and the <a href="https://www.btc-ksa.com/power-utilities">power and utilities sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Why does a combined cycle plant need bypass valves?</strong> To run the gas turbine and HRSG while the steam turbine is starting, tripped or shut down.</p><p><strong>How fast must bypass valves open?</strong> Typically within a few seconds after a turbine trip, as set by the plant design.</p><p><strong>Can BTGC repair bypass valves?</strong> Yes, testing and repair at the Jubail service center, with KOSO parts.</p><h2>Contact the BTGC valve team</h2><p>Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 07:26:01 +0300</pubDate></item></channel></rss>