<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/custody-transfer-metering/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #custody transfer metering</title><description>BTGC - Knowledge Hub #custody transfer metering</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/custody-transfer-metering</link><lastBuildDate>Wed, 18 Nov 2026 11:17:26 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Double Block and Bleed Plug Valves for Metering, Terminals and Tank Farms]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/double-block-bleed-plug-valves-metering-terminals-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/3z-double-block-bleed-plug-valves.webp"/>How expanding-plug double block and bleed valves give verifiable isolation for meters, product segregation and tank farms, and how to maintain them. 3Z Valve.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_a5Ry9KTGT7GOsobS6Fb8PA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_aYsRXhqSSRuJkCCGyG8sIA" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_g4NqPp-5SBanFSwdrFZCuA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_OldaD-6oHTSNDfDM7zgyyA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> some services need more than a valve that is believed to be shut: they need isolation that can be proven while the line is in operation. Expanding-plug double block and bleed (DBB) valves seal with two independent slips against the body, and a bleed between them shows at once whether either seal is passing. That makes them the standard choice for custody transfer meter runs and provers, multi-product terminals and tank farm manifolds. BTGC supplies 3Z Valve DBB plug valves and sleeved plug valves.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/3z-double-block-bleed-plug-valves.webp" alt="3Z double block and bleed plug valves" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>At a crude or product terminal, a few litres leaking past a closed valve can spoil a product batch, upset a meter proving run or create a dispute over a cargo. A conventional valve gives no sign of a small leak. A DBB plug valve lets the operator open a small bleed valve and see directly that the isolation is tight.</p><h2>How an expanding-plug DBB valve works</h2><ul><li><p>The plug carries two slips, each with its own resilient seal, one on each side.</p></li><li><p>To open, the operator first retracts the slips from the body, then turns the plug; the seals do not rub on the body as the valve moves.</p></li><li><p>To close, the plug turns to the closed position and then wedges the slips outwards against the body seats.</p></li><li><p>With both slips sealed, a bleed valve on the body cavity can be opened to verify that neither side is leaking.</p></li><li><p>A thermal relief valve, often relieving to the upstream side, protects the sealed cavity from pressure rise as the product warms.</p></li></ul><h2>Where they are used</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Service</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Why DBB plug valves suit it</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Custody transfer meter runs and provers</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Any leak past a closed valve during proving makes the meter factor wrong</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Multi-product pipelines and terminals</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Prevents contamination between products at manifolds</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Tank farm manifolds</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Allows safe isolation of one tank while neighbouring tanks stay in service</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Fuel gas and fuel hydrant systems</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Positive isolation for maintenance on burners and dispensers</td></tr></tbody></table><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/valve-test-bench-btgc-service-center-jubail.webp" alt="Valve test bench at the BTGC service center in Jubail" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Maintenance and checks</h2><ul><li><p>Open the body bleed after closing to confirm the seal; record results for metering audits.</p></li><li><p>Replace slip seals at planned intervals or when the bleed check shows passing; many designs allow this without removing the body from the line.</p></li><li><p>Check the thermal relief valve and the bleed valve themselves, which can block or pass.</p></li><li><p>Keep the operator or actuator adjusted so the slips fully expand when closed.</p></li><li><p>Pressure test after repair; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/valve-seat-leakage-classes-api-598-iso-5208-saudi-arabia">seat leakage classes</a>.</p></li></ul><h2>Other plug valve options</h2><p>For dirty, polymerising or corrosive services, sleeved and lined plug valves are often a better fit, as compared in <a href="https://www.btc-ksa.com/Knowledge-Hub/post/plug-valves-lubricated-sleeved-saudi-arabia">lubricated or sleeved plug valves</a>.</p><h2>3Z Valve from BTGC</h2><p>3Z Valve of Korea specialises in double block and bleed plug valves and sleeved plug valves. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/3z-valve-saudi-arabia">3Z Valve partner in Saudi Arabia</a>, with testing and repair at the BTGC service center in Jubail. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/trunnion-ball-valves-pipelines-api-6d-dbb-dib-saudi-arabia">DBB and DIB in pipeline ball valves</a> and the <a href="https://www.btc-ksa.com/flow-control-valves-solutions">flow control and valves</a> page.</p><h2>Questions buyers ask</h2><p><strong>Is one DBB plug valve as good as two valves with a bleed between them?</strong> It provides two seals and a bleed in one body, saving space and weight; the owner's isolation philosophy decides where each is accepted.</p><p><strong>Why does the body need a thermal relief?</strong> Liquid trapped between the two seals expands as it warms and can overpressure the body.</p><p><strong>Can BTGC repair existing DBB plug valves?</strong> Yes, including slip seal replacement and testing at the Jubail service center.</p><h2>Contact the BTGC valve team</h2><p>Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 10:23:09 +0300</pubDate></item></channel></rss>