<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/demineralisation/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #demineralisation</title><description>BTGC - Knowledge Hub #demineralisation</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/demineralisation</link><lastBuildDate>Wed, 18 Nov 2026 04:41:43 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Diaphragm Valves for Demineralised Water Plants in Power and Industry]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/diaphragm-valves-demineralisation-plants-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/saunders-diaphragm-valves-range.webp"/>Why demineralisation plants use lined diaphragm valves for acid, caustic and resin service, and how to keep regeneration reliable. Saunders from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_IkqTkCxgR1iDudDxJv5LtQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_m0ZkG6CCQoqDf3cBJfeZxQ" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_Gjz6aOGNRs6zmhUP6EPMlw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_9r5vwER11TtHTxyeXxh2Lw" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> power plants, petrochemical complexes and fertiliser plants need very pure, demineralised water for boilers and processes. Ion exchange units and polishing systems switch between service and regeneration, using hydrochloric or sulphuric acid and caustic soda. The many automatic valves in these units must handle corrosive chemicals and resin beads, operate thousands of times and never leak into the pure water. Lined diaphragm valves with suitable diaphragms are the standard choice. BTGC supplies Saunders industrial diaphragm valves.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/saunders-diaphragm-valves-range.webp" alt="Saunders diaphragm valves" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Boiler feedwater quality in Saudi power and industrial plants depends on reliable demineralisation, often starting from desalinated water. Valve leaks in regeneration lines can contaminate treated water or waste chemicals.</p><h2>Valve duties in a demin plant</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Duty</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Requirement</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Service inlet and outlet</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Tight shutoff to protect treated water quality</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Acid and caustic regeneration</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Corrosion resistance and chemical-compatible diaphragms</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Backwash and rinse</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Handle resin fines without damage</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Frequent cycling</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Reliable automatic operation over many cycles</td></tr></tbody></table><h2>Selection points</h2><ul><li><p>Rubber or fluoropolymer-lined bodies suited to each chemical; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/chemical-dosing-valves-desalination-water-treatment-saudi-arabia">chemical dosing valves</a>.</p></li><li><p>Diaphragm materials matched to acid, caustic and temperature.</p></li><li><p>Pneumatic actuators with position feedback for automatic sequences.</p></li><li><p>Resin traps or strainers to keep resin out of valves.</p></li><li><p>Consistent valve types across the plant to simplify spares.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/desalination-plant-saudi-arabia.webp" alt="Water treatment plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Maintenance tips</h2><ul><li><p>Replace diaphragms on a schedule based on cycles and chemical exposure.</p></li><li><p>Check actuator air supply and limit switch signals during regeneration.</p></li><li><p>Inspect linings for damage when valves are removed.</p></li><li><p>Track water quality after regeneration to detect leaking valves.</p></li><li><p>Keep spare diaphragms and actuator kits on site.</p></li></ul><h2>Saunders from BTGC</h2><p>Saunders, part of Crane ChemPharma and Energy, makes industrial and hygienic diaphragm valves. BTGC is the <a href="https://www.btc-ksa.com/saunders-saudi-arabia">Saunders partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/hygienic-diaphragm-valves-pharma-food-saudi-arabia">hygienic diaphragm valves</a> and the <a href="https://www.btc-ksa.com/power-utilities">power and utilities sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Why diaphragm valves in demin plants?</strong> They isolate chemicals from the valve mechanism, resist corrosion with linings and suit automatic cycling.</p><p><strong>How often should diaphragms be changed?</strong> Based on cycle counts and inspection; many plants change them at planned intervals.</p><p><strong>Does BTGC supply actuated diaphragm valves?</strong> Yes, with pneumatic actuators and position feedback.</p><h2>Contact the BTGC valve team</h2><p>Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 16:18:41 +0300</pubDate></item></channel></rss>