<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/dga/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #DGA</title><description>BTGC - Knowledge Hub #DGA</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/dga</link><lastBuildDate>Wed, 18 Nov 2026 05:37:47 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Transformer Oil Testing and DGA for Saudi Substations]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/transformer-oil-testing-dga-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/large-power-transformer-radiators-cooling-fans.webp"/>What dissolved gas analysis and oil tests tell you about a power transformer, how often to sample, and how to act on the results. HD Hyundai Electric from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_N3e2Nju9RaKu5w-i_r-Rhg" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_LVAXMIwPSP2IL7FxDCQjGA" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_J5iIS4B8SsGVX2QS1i56Tw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_0G5Hcws1fRnHUYq2ndhJPg" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> the oil in a power transformer records what is happening inside it. Dissolved gas analysis (DGA) detects overheating and electrical faults long before they trip the unit, and moisture, acidity and breakdown voltage show how fast the insulation is ageing. BTGC supplies HD Hyundai Electric power transformers in Saudi Arabia and supports owners with monitoring and life-extension planning.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/large-power-transformer-radiators-cooling-fans.webp" alt="Large power transformer with radiators and cooling fans" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>A power transformer at a Saudi industrial substation works hard: high ambient temperatures, heavy and sometimes harmonic-rich loads, and dust on the radiators. Its life is set by the paper insulation, and paper ages fastest when it is hot, wet and in acidic oil. The good news is that the oil carries the evidence, and sampling it is cheap compared with any failure.</p><h2>What DGA tells you</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Gas</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Typical cause</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Hydrogen (H2)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Partial discharge, the earliest sign of electrical stress</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Methane, ethane</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Low-temperature overheating of oil</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Ethylene</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Higher-temperature overheating, for example a hot joint or core fault</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Acetylene (C2H2)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Arcing; any rising trend needs urgent attention</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Carbon monoxide and dioxide</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Overheating or ageing of paper insulation</td></tr></tbody></table><p>Interpretation uses ratio methods such as the Duval triangle and IEC 60599. The trend matters more than a single value: a stable gas level in an old transformer may be normal, while a doubling between two samples is a warning even if the absolute value is low.</p><h2>The other oil tests</h2><ul><li><p><strong>Moisture in oil</strong> and the estimated moisture in paper: wet paper ages faster and lowers dielectric strength.</p></li><li><p><strong>Breakdown voltage</strong>: a quick check of contamination.</p></li><li><p><strong>Acidity and interfacial tension</strong>: show oil oxidation and sludge formation.</p></li><li><p><strong>Furan analysis</strong>: estimates the remaining strength of the paper insulation.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/hd-hyundai-electric-power-transformer-saudi-arabia.webp" alt="HD Hyundai Electric power transformer" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>A sensible monitoring programme</h2><ul><li><p>Annual DGA and oil tests on all power transformers, more often for critical or ageing units.</p></li><li><p>Online DGA monitors on generator step-up and critical plant transformers.</p></li><li><p>Radiator and fan cleaning before summer, because high top-oil temperature accelerates ageing.</p></li><li><p>Oil reclamation or drying when acidity or moisture trends up, before sludge forms on the windings.</p></li></ul><h2>HD Hyundai Electric from BTGC</h2><p>HD Hyundai Electric builds power transformers, GIS and switchgear for utilities and industry. BTGC is the <a href="https://www.btc-ksa.com/hd-hyundai-electric-saudi-arabia">HD Hyundai Electric partner in Saudi Arabia</a>, supporting specification, supply and life-cycle planning for new and installed units. See the related articles on <a href="https://www.btc-ksa.com/Knowledge-Hub/post/power-transformer-specification-saudi-arabia">power transformer specification</a> and <a href="https://www.btc-ksa.com/Knowledge-Hub/post/gas-insulated-switchgear-gis-saudi-arabia">gas-insulated switchgear</a>, and the <a href="https://www.btc-ksa.com/power-utilities">power and utilities</a> page.</p><h2>Questions buyers ask</h2><p><strong>How often should DGA be done?</strong> At least yearly for most power transformers; quarterly or online for critical or suspect units.</p><p><strong>Can a transformer with high acetylene stay in service?</strong> That depends on the level and trend; a rising acetylene trend needs an urgent engineering assessment and often a shutdown inspection.</p><p><strong>Does BTGC supply online DGA monitors?</strong> Monitoring options are specified with new HD Hyundai Electric transformers; ask BTGC for retrofit options for installed units.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Mon, 16 Nov 2026 08:59:43 +0300</pubDate></item></channel></rss>