<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/diaphragm-seals/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #diaphragm seals</title><description>BTGC - Knowledge Hub #diaphragm seals</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/diaphragm-seals</link><lastBuildDate>Wed, 18 Nov 2026 11:17:25 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Pressure Gauges Under Vibration and Pulsation: Liquid Filling, Snubbers and Diaphragm Seals]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/pressure-gauges-vibration-pulsation-diaphragm-seals-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/nuova-fima-pressure-gauges-diaphragm-seals.webp"/>Why pressure gauges fail on pumps and compressors, how liquid filling, snubbers and diaphragm seals fix it, and how to select gauges to EN 837. Nuova Fima.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_ovXmnrlARImH3FTkEGXNNQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_Icb2oclXTDKVaeheiX5vWg" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_EHJDvJVpQtWckouKw_Z7lw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_bjWhKNJwV6Oh5r4KOY_SyA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> local pressure gauges look simple, but on pumps, compressors and reciprocating machines they often fail within months: the pointer flutters, the movement wears and the Bourdon tube cracks. The fixes are well known: liquid-filled cases to damp vibration, snubbers or restrictors to calm pulsation, diaphragm seals to keep corrosive, viscous or hot media out of the gauge, and correct range selection so normal pressure sits in the middle of the scale. EN 837 sets the main design and accuracy rules. BTGC supplies Nuova Fima gauges, seals and thermometers.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/nuova-fima-pressure-gauges-diaphragm-seals.webp" alt="Nuova Fima pressure gauges and diaphragm seals" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Plant operators rely on local gauges during start-up, troubleshooting and rounds. A gauge that reads wrong or has failed hides real problems, and a cracked Bourdon tube can release process fluid. In Saudi plants, heat, sun and sand add to the load on gauges installed outdoors.</p><h2>Common problems and fixes</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Problem</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Cause</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Fix</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Pointer flutter, worn movement</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Machine vibration</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Glycerine or silicone filled case; remote mounting with capillary</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Pointer swinging, cracked Bourdon tube</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Pressure pulsation from reciprocating pumps or compressors</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Snubber, restrictor screw or pulsation damper; gauge with damped movement</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Blocked or corroded element</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Corrosive, viscous, crystallising or dirty media</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Diaphragm seal with suitable wetted materials and fill fluid</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Overrange damage</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Pressure spikes or wrong range</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Range so normal pressure is in the middle third of the scale; overpressure protector</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Wrong reading in hot service</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Heat reaching the gauge</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Siphon for steam, cooling tower or diaphragm seal with capillary</td></tr></tbody></table><h2>Selection points</h2><ul><li><p>Accuracy class to EN 837-1, for example class 1.0 for process gauges and 0.25 or better for test gauges.</p></li><li><p>Case and wetted parts in stainless steel for outdoor and corrosive locations; safety pattern case with blow-out back and solid front for gas and high pressure service.</p></li><li><p>Dial size for readability from the operating position, commonly 100 or 150 mm.</p></li><li><p>Diaphragm seal fill fluid suited to the process temperature and approved for food or pharma where needed.</p></li><li><p>Sour service materials where H2S is present.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/process-piping-petrochemical-plant.webp" alt="Process piping in a petrochemical plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Maintenance and calibration</h2><ul><li><p>Calibrate on a schedule against a reference, and replace gauges that fail calibration rather than adjusting repeatedly.</p></li><li><p>Check liquid level in filled gauges and look for leaks or discoloured fill.</p></li><li><p>Inspect diaphragm seals for damage after process upsets.</p></li><li><p>Record gauge failures by location; repeat failures show where a snubber or seal is needed.</p></li><li><p>Pair local gauges with transmitters for critical points so readings can be trended; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/api-plan-53a-53b-53c-comparison-saudi-pumps">API Plan 53 seal support systems</a>.</p></li></ul><h2>Nuova Fima from BTGC</h2><p>Nuova Fima of Italy makes pressure gauges, diaphragm seals, thermometers, transmitters and switches for oil and gas, petrochemical and power plants. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/nuova-fima-saudi-arabia">Nuova Fima partner in Saudi Arabia</a>. See also the <a href="https://www.btc-ksa.com/petrochemicals">petrochemicals sector</a> and <a href="https://www.btc-ksa.com/oil-gas">oil and gas sector</a> pages.</p><h2>Questions buyers ask</h2><p><strong>Does liquid filling help with pulsation?</strong> It damps vibration and some pulsation, but strong pulsation also needs a snubber or damper.</p><p><strong>When is a diaphragm seal needed?</strong> For corrosive, viscous, crystallising, hot or hygienic media that must not enter the gauge element.</p><p><strong>Can BTGC supply gauges with calibration certificates?</strong> Yes, with factory calibration certificates and material certificates on request.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 10:25:52 +0300</pubDate></item></channel></rss>