<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/electrical/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #Electrical</title><description>BTGC - Knowledge Hub #Electrical</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/electrical</link><lastBuildDate>Wed, 18 Nov 2026 11:16:14 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Control and Instrumentation Cables: Screening, Armour and Hazardous Areas]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/control-instrumentation-cables-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/bahra-electric-power-cables.webp"/>How to choose control and instrumentation cables: pairs, screening against noise, armour, fire performance and hazardous areas. Bahra Electric.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_JrOB01zJR7uOTktJyvQesA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_WOEhYioJSO6fAmmj6NefwA" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_Hn5EZzuCRja4S9dkO19IdA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_JUEJdtgXwD7FcAs-kjmAaw" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> instrumentation cables carry the small signals from transmitters, analysers and switches to control and safety systems, while control cables carry commands to valves, motors and alarms. Noise from power cables and drives can corrupt signals, fire can destroy cables that safety systems depend on, and hazardous areas add their own rules. The right construction, screening, armour, fire performance and routing protect signal quality and safety. BTGC supplies Bahra Electric control and instrumentation cables made in the Kingdom.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/bahra-electric-power-cables.webp" alt="Bahra Electric cables" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Refineries, gas plants, petrochemical complexes and power stations in the Kingdom use thousands of kilometres of control and instrumentation cable. Signal problems and cable failures are often hard to trace.</p><h2>Construction choices</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Element</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Options</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Conductors</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Twisted pairs or triads for analogue signals; multicore for control</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Screening</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Individual and overall screens to reduce electrical noise</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Armour</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Steel wire or braid for mechanical protection in buried and exposed runs</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Sheath</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">PVC, LSZH or other materials depending on fire and environmental needs</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Fire performance</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Flame-retardant or fire-resistant cables for safety circuits that must keep working in a fire</td></tr></tbody></table><h2>Avoiding signal problems</h2><ul><li><p>Separate instrument cables from power and drive cables in trays and routes.</p></li><li><p>Earth screens at one end, usually the control room, unless the system design says otherwise.</p></li><li><p>Use twisted pairs for analogue signals to cancel noise.</p></li><li><p>Choose suitable cables for fieldbus and data networks.</p></li><li><p>Keep junction boxes sealed against dust and moisture.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/process-piping-petrochemical-plant.webp" alt="Process plant with cable routes" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Hazardous areas and safety circuits</h2><ul><li><p>Follow the area classification and cable rules for intrinsically safe and other protection methods.</p></li><li><p>Use blue-sheathed or clearly identified cables for intrinsically safe circuits where required.</p></li><li><p>Use fire-resistant cables for emergency shutdown and fire and gas circuits where specified.</p></li><li><p>Use certified cable glands matched to the cable type.</p></li><li><p>Record cable schedules and test results for future maintenance.</p></li></ul><h2>Bahra Electric from BTGC</h2><p>Bahra Electric is a Saudi manufacturer of power, control and instrumentation cables and busways. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/bahra-electric-saudi-arabia">Bahra Electric partner</a> for plants and projects. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/medium-voltage-power-cables-selection-saudi-arabia">medium voltage cables</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/busway-busbar-trunking-vs-cables-saudi-arabia">busways</a> and the <a href="https://www.btc-ksa.com/electrical-power-systems-saudi-arabia">electrical power systems</a> page.</p><h2>Questions buyers ask</h2><p><strong>Why use individually screened pairs?</strong> They reduce crosstalk and noise between signals in the same cable.</p><p><strong>Where are fire-resistant cables needed?</strong> For circuits that must keep working during a fire, such as some shutdown and fire and gas systems.</p><p><strong>Does BTGC supply locally made instrumentation cables?</strong> Yes, through Bahra Electric.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 16:21:15 +0300</pubDate></item><item><title><![CDATA[Process Chillers for Industrial Machines in Hot Climates]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/process-chillers-industrial-machines-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/pfannenberg-enclosure-cooling-units.webp"/>How process chillers cool lasers, machine tools, hydraulics, plastics and lab equipment, and how to size and maintain them for Saudi heat. Pfannenberg.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_TCgPcCdpRluXQa6HrWxyOg" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_u3eIDu4MTSKJIrkyalXPXA" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_Eu-x25ACTfO4H4Y33Inubw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_6Zdc1eYR9a2OHMbpFEuIYQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> many machines need their own cooling water or fluid at a controlled temperature: laser cutters, machine tool spindles, hydraulic power units, plastic moulding machines, welding equipment, induction heaters and laboratory instruments. A compact process chiller delivers this reliably, independent of the plant cooling system. In Saudi summers, ambient air can exceed the design conditions of standard chillers, so sizing, location and maintenance are critical. BTGC supplies Pfannenberg process chillers and enclosure cooling.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/pfannenberg-enclosure-cooling-units.webp" alt="Pfannenberg cooling units and chillers" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Manufacturing, metalworking, plastics, packaging and laboratories in the Kingdom increasingly use precision machines that stop or lose accuracy when their coolant temperature drifts.</p><h2>Typical applications</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Machine</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">What is cooled</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Laser cutting and welding</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Laser source and optics</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Machine tools</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Spindles, hydraulic and cutting fluid</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Hydraulic power units</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Hydraulic oil temperature</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Plastic injection and extrusion</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Moulds, barrels and hydraulics</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Induction heating and welding</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Coils and power electronics</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Laboratory and analytical equipment</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Instrument stability</td></tr></tbody></table><h2>Sizing for hot climates</h2><ul><li><p>Add up the heat load from the machine data, with margin.</p></li><li><p>Size for the highest expected ambient air temperature at the chiller location, not a 32 degC reference.</p></li><li><p>Choose the outlet temperature and stability the machine needs.</p></li><li><p>Consider indoor installation with ventilation, or water-cooled condensers where cooling water is available.</p></li><li><p>Select fluid type: water, water-glycol or oil, as the machine requires.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/process-piping-petrochemical-plant.webp" alt="Industrial plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Maintenance tips</h2><ul><li><p>Clean condenser coils regularly; dust raises condensing pressure and causes trips.</p></li><li><p>Check fluid level, quality and inhibitor concentration.</p></li><li><p>Replace filters and strainers on schedule.</p></li><li><p>Watch alarms for high pressure, low flow and temperature deviation.</p></li><li><p>Plan service before the summer peak.</p></li></ul><h2>Pfannenberg from BTGC</h2><p>Pfannenberg of Germany makes process chillers, enclosure cooling units, filter fans and signalling devices. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/pfannenberg-saudi-arabia">Pfannenberg partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/enclosure-cooling-electrical-panels-saudi-arabia">enclosure cooling</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/hydraulic-oil-hot-climate-saudi-arabia">hydraulic oil in hot climates</a> and the <a href="https://www.btc-ksa.com/electrical-power-systems-saudi-arabia">electrical power systems</a> page.</p><h2>Questions buyers ask</h2><p><strong>Why does my chiller trip on high pressure in summer?</strong> The condenser cannot reject heat at high ambient, often made worse by dirty coils; cleaning and correct sizing help.</p><p><strong>Can one chiller cool several machines?</strong> Yes, if the total load, temperatures and fluids match, but critical machines often have their own.</p><p><strong>Does BTGC help size chillers?</strong> Yes, from machine data and site conditions.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 14:23:03 +0300</pubDate></item><item><title><![CDATA[Busways or Cables for Low Voltage Power Distribution in Plants and Buildings]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/busway-busbar-trunking-vs-cables-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/bahra-electric-power-cables.webp"/>When busbar trunking (busways) beats cables for low voltage distribution in plants, data centres and buildings, and how to maintain it. Bahra Electric.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_0qgvP-o4Q1y1NyRD5kf3Ww" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_sG0FHTwJRbOr5UUwk3qx6Q" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_lstILTmlTu--OSw_eN_9Xw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_CxvQvoQwiooPpT-Hkgj8BA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> large low voltage currents, from transformers to main switchboards and from risers to floors and machines, can be carried by many parallel cables or by busbar trunking, also called busway. Busways deliver high current in a compact, factory-built system with tap-off points, and are quicker to install and change. Cables are more flexible for routes with many bends and for long, spread-out loads. The right choice depends on current, route, flexibility and heat. BTGC supplies Bahra Electric cables and busways.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/bahra-electric-power-cables.webp" alt="Bahra Electric power cables" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Factories, data centres, hospitals, airports, high-rise buildings and plant substations in the Kingdom carry thousands of amps at low voltage. Hot electrical rooms and long risers make heat and voltage drop key design factors.</p><h2>Busways and cables compared</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Point</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Busway</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Cables</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">High current</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Very compact for thousands of amps</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Many parallel cables, large trays</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Installation</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Fast, prefabricated sections</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Slower pulling and termination</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Flexibility</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Tap-off units can be added or moved</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Changes need new cables</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Route</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Best for straight runs and risers</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Better for complex routes</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Voltage drop and losses</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Low impedance designs available</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Depends on size and arrangement</td></tr></tbody></table><h2>Specification points</h2><ul><li><p>Rated current at the actual ambient temperature of the room or riser.</p></li><li><p>Short-circuit withstand matching the transformer and switchboard fault level.</p></li><li><p>Conductor material: copper or aluminium, and insulation system.</p></li><li><p>Ingress protection and fire rating, with fire barriers where busways pass through walls and floors.</p></li><li><p>Tap-off unit types and protection for the connected loads.</p></li><li><p>Design and type testing to IEC 61439-6 for busbar trunking systems.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/hd-hyundai-electric-transformer-gis.webp" alt="Substation and power distribution equipment" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Installation and maintenance</h2><ul><li><p>Support sections as specified and allow for thermal expansion on long runs.</p></li><li><p>Torque joint bolts to the maker's values and record them.</p></li><li><p>Check joints with thermography under load at regular intervals.</p></li><li><p>Keep risers clean and dry; dust and moisture reduce insulation.</p></li><li><p>Re-torque or inspect joints after any fault event.</p></li></ul><h2>Bahra Electric from BTGC</h2><p>Bahra Electric is a Saudi manufacturer of medium and high voltage power cables, low voltage and control cables, and busways. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/bahra-electric-saudi-arabia">Bahra Electric partner</a> for plants and projects. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/medium-voltage-power-cables-selection-saudi-arabia">medium voltage cables</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/compact-substations-package-units-saudi-arabia">compact substations</a> and the <a href="https://www.btc-ksa.com/electrical-power-systems-saudi-arabia">electrical power systems</a> page.</p><h2>Questions buyers ask</h2><p><strong>Is a busway always cheaper than cables?</strong> Not always; it usually wins at high currents and straight routes, especially when installation time is counted.</p><p><strong>Can tap-off units be added later?</strong> Yes, at the tap-off points provided along the busway.</p><p><strong>Does BTGC supply locally made busways?</strong> Yes, Bahra Electric manufactures busways in the Kingdom.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 14:08:43 +0300</pubDate></item><item><title><![CDATA[Cooling Electrical Panels and Drive Enclosures in Saudi Heat]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/enclosure-cooling-electrical-panels-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/pfannenberg-enclosure-cooling-units.webp"/>How to keep VFDs, PLCs and switchgear panels cool in Saudi heat: fans, heat exchangers or cooling units, heat load sizing and condensation. Pfannenberg.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_Ce7kDqRhTOu8_1mXhuo8pw" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_n1pbgZPTQ2q9cCldlVUObQ" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_RK2HPtD9RcWzqEv-tN_Pyg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_gNP4rZgAnJ_o2YxC-iWqKA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> electronics fail early when they run hot. Drives, PLCs, power supplies and protection relays inside closed panels add their own heat to the hot air around them, and in Saudi summers the outside air is often hotter than the electronics can tolerate. Filter fans and air-to-air heat exchangers only work when the outside air is cooler than the required panel temperature; otherwise a refrigerant cooling unit or an air-to-water heat exchanger is needed. Correct sizing, sealing and condensate handling are the keys. BTGC supplies Pfannenberg enclosure cooling, chillers and signalling products.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/pfannenberg-enclosure-cooling-units.webp" alt="Pfannenberg enclosure cooling units" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Outdoor kiosks, motor control centres, VFD panels in pump stations and control panels on skids are common in Saudi plants. Many electronics are rated for about 40 to 50 degC, while panels in the sun can easily exceed that without active cooling.</p><h2>Choosing the cooling method</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Method</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Works when</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Notes</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Filter fan</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Outside air is well below the required panel temperature</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Cheapest; brings in dust, so filters need cleaning</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Air-to-air heat exchanger</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Outside air is below the panel temperature</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Keeps the panel sealed from dust</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Cooling unit (panel air conditioner)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Outside air is hotter than the required panel temperature</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Usual choice for Saudi summers; needs condensate management</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Air-to-water heat exchanger</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Chilled or cooling water is available</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">High capacity, sealed panel</td></tr></tbody></table><h2>Sizing the heat load</h2><ul><li><p>Add the heat losses of all equipment; drives typically lose a few percent of their rated power as heat.</p></li><li><p>Add heat entering through the panel walls from hot air and direct sun.</p></li><li><p>Choose the maximum allowed inside temperature from the equipment data, often around 35 degC.</p></li><li><p>Size for the hottest expected ambient, not the yearly average.</p></li><li><p>Shade outdoor panels where possible to cut solar gain.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/danfoss-vacon-ac-drives-range.webp" alt="AC drives inside an electrical panel" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Installation and maintenance</h2><ul><li><p>Keep the panel sealed to its IP rating; open cable entries let in hot, dusty air. See <a href="https://www.btc-ksa.com/Knowledge-Hub/post/ip-ratings-plugs-sockets-enclosures-saudi-arabia">IP ratings</a>.</p></li><li><p>Arrange airflow so cold air reaches equipment and does not short-circuit back to the unit.</p></li><li><p>Fit door switches so cooling units stop when the door is open, reducing condensation.</p></li><li><p>Lead condensate safely away from electrical equipment.</p></li><li><p>Clean condenser coils and filters regularly; dust is the main cause of cooling unit trips.</p></li></ul><h2>Pfannenberg from BTGC</h2><p>Pfannenberg of Germany makes filter fans, cooling units, heat exchangers and process chillers for electrical enclosures, and signalling devices. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/pfannenberg-saudi-arabia">Pfannenberg partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/vfd-pumps-fans-energy-savings-harmonics-saudi-arabia">VFDs for pumps and fans</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/substation-ups-batteries-high-temperature-nicd-lead-acid-saudi-arabia">batteries in Saudi heat</a> and the <a href="https://www.btc-ksa.com/electrical-power-systems-saudi-arabia">electrical power systems</a> page.</p><h2>Questions buyers ask</h2><p><strong>Why does my drive panel trip on high temperature only in summer?</strong> The outside air is too hot for fans to cool the panel; a cooling unit is usually needed.</p><p><strong>Can a cooling unit be fitted to an existing panel?</strong> Yes, on the side wall, door or roof, after checking the heat load and panel structure.</p><p><strong>Does BTGC help with heat load calculations?</strong> Yes, from the equipment list, panel size and site conditions.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 11:59:45 +0300</pubDate></item></channel></rss>