<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/energy-efficiency/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #energy efficiency</title><description>BTGC - Knowledge Hub #energy efficiency</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/energy-efficiency</link><lastBuildDate>Wed, 18 Nov 2026 11:16:28 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Compressed Air Audits: Measure Demand Before Buying a Compressor]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/compressed-air-audit-demand-measurement-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/ingersoll-rand-centrifugal-air-compressor.webp"/>Why a compressed air audit should come before a new compressor: logging flow and pressure, leaks, artificial demand and right-sizing. Ingersoll Rand, BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_8hsF0pyFTziMw2GVTUyPzg" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm__TTehUbnRim4AiCaenX2pQ" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_Z3TJ0el2TkKaUkVz0TRVXg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_ZONNGXkYZJKyk2q3pYJliA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> plants often buy a bigger compressor when pressure drops, but the real cause may be leaks, poor piping or users running at higher pressure than they need. A compressed air audit logs flow, pressure and power over one or two weeks, finds leaks and waste, and shows the real demand profile. Only then can the right compressor size and control be chosen. BTGC supplies Ingersoll Rand compressors and blowers with maintenance support.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/ingersoll-rand-centrifugal-air-compressor.webp" alt="Ingersoll Rand centrifugal air compressor" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Compressed air is one of the most expensive utilities in a plant, and Saudi summers push compressors to their limits.</p><h2>What an audit measures</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Item</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Why</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Flow over time</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Shows base load, peaks and night demand</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Pressure at compressors and users</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Reveals pressure drop in piping and treatment</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Power and loading of each compressor</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Shows efficiency and wasted unloaded running</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Leaks</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Often a large share of total demand</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Air quality</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Moisture, oil and particles against what users need</td></tr></tbody></table><h2>Common findings</h2><ul><li><p>Leaks at hoses, fittings and drains wasting a large share of air.</p></li><li><p>Header pressure set higher than any user needs.</p></li><li><p>Open blowing, cleaning with air guns and other low-value uses.</p></li><li><p>Undersized pipes and clogged filters causing pressure drop; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/compressed-air-piping-design-saudi-arabia">piping design</a>.</p></li><li><p>Several compressors part-loaded instead of one well-loaded machine.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/process-piping-petrochemical-plant.webp" alt="Compressed air and process piping" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Turning results into action</h2><ul><li><p>Fix leaks first, then re-measure demand.</p></li><li><p>Reduce pressure step by step while watching users.</p></li><li><p>Size new compressors for the measured profile, with base-load and trim machines.</p></li><li><p>Add storage and sequencing controls; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/compressed-air-energy-savings-saudi-arabia">compressed air energy savings</a>.</p></li><li><p>Repeat audits every few years or after plant changes.</p></li></ul><h2>Ingersoll Rand from BTGC</h2><p>Ingersoll Rand makes centrifugal air compressors and blowers. BTGC supplies <a href="https://www.btc-ksa.com/Knowledge-Hub/post/ingersoll-rand-saudi-arabia">Ingersoll Rand in Saudi Arabia</a> with spare parts and maintenance support. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/compressor-room-ventilation-hot-climate-saudi-arabia">compressor rooms in hot climates</a> and the <a href="https://www.btc-ksa.com/petrochemicals">petrochemicals sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>How long should an audit run?</strong> Usually one to two weeks, covering normal production and weekends.</p><p><strong>Can leaks really be that large?</strong> Yes, in older plants leaks are often one of the largest single users of air.</p><p><strong>Do I need to stop production for an audit?</strong> No, loggers are fitted while the plant runs.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 15:00:37 +0300</pubDate></item><item><title><![CDATA[Cutting Compressed Air Energy Costs: Leaks, Pressure and Compressor Control]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/compressed-air-energy-savings-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/ihi-turbo-compressor-package.webp"/>Where compressed air systems waste energy, from leaks and high pressure to poor compressor control, and practical steps to cut costs. IHI compressors from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_hlDsFgUMQX6E6zWJcDu5XQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_ZQ1IayqUR6-UPAmXtlFBPQ" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_39C8I2PST2CscgkjMKR20A" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_tKZFpHZsE7MVV3_-9nJzzA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> compressed air is one of the most expensive utilities in a plant, because most of the electrical energy used by compressors becomes heat. Leaks, pressure set higher than needed, compressors running unloaded and poor control between several machines waste a large share of that energy. A structured approach, measuring demand, fixing leaks, lowering pressure and improving control, often cuts compressed air energy use substantially. BTGC supplies IHI turbo and screw compressors.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/ihi-turbo-compressor-package.webp" alt="IHI compressor package" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Rising electricity prices and energy efficiency programmes in the Kingdom are pushing plants to look at utilities such as compressed air. Many systems have grown over years without a review.</p><h2>Where energy is wasted</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Waste</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Typical cause</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Leaks</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Fittings, hoses, valves and drains; can be a large share of demand</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">High pressure</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Set point raised to cover pressure drops or one demanding user</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Unloaded running</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Compressors running without producing air</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Poor sequencing</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Several compressors part-loaded instead of one fully loaded</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Inappropriate uses</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Open blowing, cooling and cleaning with compressed air</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Pressure drop</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Undersized pipes, dirty filters and dryers</td></tr></tbody></table><h2>Practical steps</h2><ul><li><p>Measure flow, pressure and power to understand real demand.</p></li><li><p>Run regular leak surveys with ultrasonic detectors and fix leaks quickly.</p></li><li><p>Lower header pressure to the minimum users need.</p></li><li><p>Use a master controller to sequence compressors.</p></li><li><p>Replace wasteful uses with blowers or other equipment.</p></li><li><p>Recover heat from compressors for process or water heating where possible.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/gas-cracker-plant-saudi-arabia.webp" alt="Industrial plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Large compressor stations</h2><ul><li><p>Match compressor type to load: turbo compressors for large base loads, screw compressors for variable trim duty; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/turbo-compressors-plant-air-air-separation-saudi-arabia">turbo compressors</a>.</p></li><li><p>Keep intercoolers and inlet filters clean; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/compressor-intercoolers-aftercoolers-saudi-arabia">intercoolers</a>.</p></li><li><p>Minimise blow-off on turbo compressors with good control.</p></li><li><p>Track energy per cubic metre of air each month.</p></li></ul><h2>IHI from BTGC</h2><p>IHI Corporation of Japan makes turbo compressors for plant air and air separation and oil-free screw compressors for process gas. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/ihi-saudi-arabia">IHI partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/instrument-air-quality-dryers-iso-8573-saudi-arabia">instrument air quality</a> and the <a href="https://www.btc-ksa.com/rotating-equipment">rotating equipment</a> page.</p><h2>Questions buyers ask</h2><p><strong>How much can a leak survey save?</strong> Often a significant share of compressed air energy, depending on how leaky the system is.</p><p><strong>Does lowering pressure really save energy?</strong> Yes, compressors use less power at lower discharge pressure.</p><p><strong>Can BTGC help audit our system?</strong> Yes, with measurement and recommendations.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 16:27:34 +0300</pubDate></item><item><title><![CDATA[Aeration Blowers for Wastewater Treatment: Choosing for Efficiency and Turndown]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/aeration-blowers-wastewater-treatment-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/ingersoll-rand-centrifugal-air-compressor.webp"/>How to choose aeration blowers for wastewater plants: lobe, screw, multistage and turbo types, turndown, control and hot-climate effects. Ingersoll Rand.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_F4ZDvul-RSSdOamWT66DGQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_85MoJJ0LTaC1QjuqXgMF5g" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_RRS3lH6VQg65FrUATp7aXA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_zxVpqSPJgjTJnTwd7y_chg" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> in activated sludge wastewater plants, the blowers that supply air to the aeration tanks are usually the biggest energy users on site. Choosing the right blower type and controlling it to the actual oxygen demand can save a large share of plant energy. Rotary lobe, rotary screw, multistage centrifugal and single-stage turbo blowers all have a place; the best choice depends on airflow range, pressure, turndown and how many machines share the load. BTGC supplies Ingersoll Rand centrifugal compressors and blowers.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/ingersoll-rand-centrifugal-air-compressor.webp" alt="Ingersoll Rand centrifugal compressor and blower" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>The Kingdom is expanding sewage treatment and water reuse quickly, and many plants operate at varying loads through the day and the year. Blowers sized only for peak load often run inefficiently most of the time.</p><h2>Blower types compared</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Type</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Strengths</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Limits</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Rotary lobe</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Simple, robust, wide pressure range</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Lower efficiency, noise</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Rotary screw blower</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Better efficiency than lobe blowers, good turndown with speed control</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Higher cost than lobe</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Multistage centrifugal</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Proven, durable for large flows</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Limited turndown, lower efficiency at part load</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Single-stage turbo (geared or high-speed)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">High efficiency, good turndown with guide vanes or speed control</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Higher first cost, needs good inlet filtration</td></tr></tbody></table><h2>Getting efficiency in operation</h2><ul><li><p>Control airflow from dissolved oxygen measurements in each aeration zone.</p></li><li><p>Use pressure set points that follow demand rather than a fixed high pressure.</p></li><li><p>Combine machines of different sizes so the duty blower runs near its best efficiency.</p></li><li><p>Keep diffusers clean; fouled diffusers raise pressure and power.</p></li><li><p>Account for hot inlet air in summer, which reduces air mass delivered.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/desalination-plant-saudi-arabia.webp" alt="Water treatment plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Maintenance points</h2><ul><li><p>Change inlet filters on schedule; dust in the Kingdom loads them quickly.</p></li><li><p>Trend vibration, bearing temperature and motor current.</p></li><li><p>Check blow-off and check valves for leakage.</p></li><li><p>Service lubrication systems and couplings according to the maker's plan.</p></li><li><p>Review energy use per cubic metre of air each month to spot problems early.</p></li></ul><h2>Ingersoll Rand from BTGC</h2><p>Ingersoll Rand makes compressed air and gas equipment, including centrifugal air compressors and blowers for industry and wastewater treatment. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/ingersoll-rand-saudi-arabia">Ingersoll Rand partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/wastewater-lift-station-pumps-saudi-arabia">wastewater lift station pumps</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/vfd-pumps-fans-energy-savings-harmonics-saudi-arabia">VFDs for pumps and fans</a> and the <a href="https://www.btc-ksa.com/power-utilities">power and utilities sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>How much energy do aeration blowers use?</strong> They are often the largest single energy use in an activated sludge plant, commonly around half of the total.</p><p><strong>Can old blowers be replaced without changing the aeration system?</strong> Usually yes, if the new blowers match the pressure and flow range; controls are often upgraded at the same time.</p><p><strong>Does BTGC offer energy surveys?</strong> Yes, with Ingersoll Rand data on existing blower performance and options.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 11:55:25 +0300</pubDate></item><item><title><![CDATA[VFDs for Pumps and Fans: Energy Savings, Harmonics and Heat Derating]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/vfd-pumps-fans-energy-savings-harmonics-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/danfoss-vacon-ac-drives-range.webp"/>How variable frequency drives cut pump and fan energy, how to meet IEEE 519 harmonic limits, and how to size drives for Saudi heat. Danfoss VACON drives, BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_BqY-m47JTBaVZYK73dE0bg" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_AYRZSCgLQS-EukGVQl9zsA" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_LzS5CV2ORiGYLi5yLWqYGg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_TNAVaBIlQofgNJ1QYmkHAQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> for centrifugal pumps and fans, flow varies with speed, but power varies roughly with the cube of speed. Running at 80 percent speed instead of throttling can cut power by around half. That is why variable frequency drives (VFDs) pay back quickly on variable-flow pumps, cooling tower fans and air handling units. Drives also bring issues to manage: harmonic currents on the supply, motor insulation stress, and derating in high ambient temperatures. BTGC supplies Danfoss VACON low and medium voltage drives.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/danfoss-vacon-ac-drives-range.webp" alt="Danfoss VACON AC drives range" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Water transmission and distribution, district cooling, desalination, HVAC and process cooling are major energy users in the Kingdom. Saudi energy efficiency programmes and rising tariffs make speed control on these loads one of the clearest efficiency upgrades.</p><h2>Where the savings come from</h2><ul><li><p>Affinity laws: flow is proportional to speed, head to speed squared and power to speed cubed.</p></li><li><p>Throttling a valve or damper wastes the extra head; reducing speed removes it.</p></li><li><p>Savings are largest where the load varies widely and runs long hours; systems with high static head save less.</p></li><li><p>Soft starting reduces mechanical stress and inrush current, extending pump and motor life.</p></li></ul><h2>Harmonics and power quality</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Solution</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Typical result</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">6-pulse drive with DC or AC choke</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Basic reduction; current distortion often 30 to 45 percent</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Passive harmonic filter</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Current distortion reduced to around 5 to 10 percent</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Active front end (low harmonic drive)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Current distortion below about 5 percent; can also regenerate</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">12- or 18-pulse with phase-shifting transformer</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Common on medium voltage and large low voltage drives</td></tr></tbody></table><p>IEEE 519 sets harmonic limits at the point of common coupling, and utilities in the Kingdom may set their own requirements. A harmonic study during design avoids overheating of transformers and cables, nuisance trips and interference with other equipment.</p><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/desalination-plant-saudi-arabia.webp" alt="Desalination plant pumping station" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Installing drives in hot climates</h2><ul><li><p>Most drives are rated for 40 to 50 &deg;C; above that they must be derated or oversized, so specify the real room temperature.</p></li><li><p>Cool electrical rooms properly; heat from drives can be large at full load.</p></li><li><p>Use IP-rated enclosures and filters against dust; keep heat sinks clean.</p></li><li><p>Use motors suitable for inverter duty, and dV/dt or sine filters for long cables to protect insulation and bearings.</p></li><li><p>Check bearing currents on larger motors; insulated bearings or shaft grounding may be needed.</p></li></ul><h2>Danfoss VACON from BTGC</h2><p>Danfoss Drives supplies VACON and VLT low and medium voltage AC drives for pumps, fans, compressors and process machines. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/danfoss-vacon-saudi-arabia">Danfoss VACON partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/soft-starting-heavy-duty-motors-weg-mv-soft-starters-vs-vfds-saudi-arabia">MV soft starters or VFDs</a>, the <a href="https://www.btc-ksa.com/electrical-power-systems-saudi-arabia">electrical power systems</a> page and the <a href="https://www.btc-ksa.com/power-utilities">power and utilities sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Does a VFD always save energy?</strong> Only where the load varies. A pump running at constant full flow gains little and the drive adds small losses.</p><p><strong>Can an existing motor run on a VFD?</strong> Often yes, after checking insulation, cooling at low speed and bearing currents.</p><p><strong>Can BTGC do a savings estimate?</strong> Yes, from the duty profile, pump curves and running hours.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 10:28:32 +0300</pubDate></item></channel></rss>