<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/fci-70-2/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #FCI 70-2</title><description>BTGC - Knowledge Hub #FCI 70-2</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/fci-70-2</link><lastBuildDate>Wed, 18 Nov 2026 11:17:02 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Control Valve Seat Leakage Classes: ANSI/FCI 70-2 Class II to VI]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-seat-leakage-classes-fci-70-2-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/koso-severe-service-control-butterfly-valves.webp"/>What control valve leakage classes II to VI mean, how they are tested, and when to ask for Class V or VI, with tips on trim and actuator thrust. KOSO, BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_3ma_6mhARJSQ7RXiB138dw" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_HGLfFUToTaawrrTq-Cji-w" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_yFPFI-XTSZ-9ghL0_61h-Q" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_GbxqoYEJXgyST3TNOnbucQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> control valves are built to regulate flow, not always to shut off tight, so their seat leakage is graded in classes defined by ANSI/FCI 70-2 (and IEC 60534-4). Class IV is common for metal seats, Class V for tight metal seats and Class VI for soft seats. Asking for a tighter class than needed adds cost and actuator size, while asking for too little can waste energy or erode trims. BTGC supplies KOSO control valves and tests valves at its Jubail service center.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/koso-severe-service-control-butterfly-valves.webp" alt="KOSO severe service control valves" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Process and power plants in the Kingdom specify control valve leakage on every data sheet, often without knowing what the class means in practice.</p><h2>The classes in brief</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Class</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Allowed leakage (summary)</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Typical seat</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">II</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">0.5% of rated capacity</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Metal, double-seated valves</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">III</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">0.1% of rated capacity</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Metal, balanced trims</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">IV</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">0.01% of rated capacity</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Metal seats, common default</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">V</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Very small water leakage per inch of port diameter per psi</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Tight metal seats, high thrust</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">VI</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Bubbles per minute of air, by port size</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Soft seats</td></tr></tbody></table><h2>Choosing the class</h2><ul><li><p>Use Class IV where the valve throttles and a separate block valve isolates.</p></li><li><p>Ask for Class V where leakage wastes high-pressure fluid, erodes the seat or affects safety, such as boiler feedwater and high-pressure drop duties.</p></li><li><p>Use Class VI soft seats only within their temperature and media limits.</p></li><li><p>Remember that tighter classes need more actuator thrust to seat the plug.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/valve-test-bench-btgc-service-center-jubail.webp" alt="Valve test bench at the BTGC Jubail service center" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Testing and service</h2><ul><li><p>Seat leakage is tested at the factory and again after repairs, using the method in the standard.</p></li><li><p>Damaged trims leak more over time; plan overhauls before leakage harms the process; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-overhaul-rebuild-saudi-arabia">control valve overhaul</a>.</p></li><li><p>For isolation valves, different standards apply; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/valve-seat-leakage-classes-api-598-iso-5208-saudi-arabia">API 598 and ISO 5208</a>.</p></li><li><p>Review sizing when duty changes; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-sizing-cv-rangeability-saudi-arabia">control valve sizing</a>.</p></li></ul><h2>KOSO from BTGC</h2><p>Nihon KOSO makes control valves and actuators known for severe service trims. BTGC supplies <a href="https://www.btc-ksa.com/koso-saudi-arabia">KOSO in Saudi Arabia</a> with sizing support and spares, and tests valves at the <a href="https://www.btc-ksa.com/btgc-jubail-service-center">Jubail service center</a>.</p><h2>Questions buyers ask</h2><p><strong>Is Class VI always better?</strong> No; soft seats have temperature and erosion limits, and metal seats with Class V may suit hard duties better.</p><p><strong>Can a valve meet a tighter class after repair?</strong> Sometimes, with new trim and lapping; the actuator must still give enough thrust.</p><p><strong>Can BTGC test leakage on site valves?</strong> Valves can be tested at the BTGC Jubail service center.</p><h2>Contact the BTGC valve team</h2><p>Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 14:32:05 +0300</pubDate></item><item><title><![CDATA[Valve Seat Leakage Classes Explained: API 598, ISO 5208 and FCI 70-2]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/valve-seat-leakage-classes-api-598-iso-5208-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/nakakita-valves-remote-control-range.webp"/>What seat leakage classes mean for isolation and control valves under API 598, ISO 5208 and ANSI/FCI 70-2, and how to specify them. Nakakita valves from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_Xcw_DgzjQKSDxvJWSpkydQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_bv9BtpYhR1ScvQEoUTNt8g" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_Sowlvr4vQhaPQso2LmJbrg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_RNaSU9WBfZ3EUdaNn87PKQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> zero leakage means different things in different standards. Isolation valves are tested to API 598, ISO 5208 or EN 12266-1, which set allowable leakage by valve type and seat material; control valves are rated to ANSI/FCI 70-2 classes II to VI, which allow measurable leakage in all but the tightest classes. Naming the right standard and class, and witnessing the test, avoids disputes and leaking valves. BTGC supplies Nakakita control, butterfly and safety valves tested to the required standards.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/nakakita-valves-remote-control-range.webp" alt="Nakakita control and automatic valves" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>A purchase order that says bubble-tight or zero leakage without naming a standard invites an argument at the factory acceptance test. Valve leakage is always measured under defined conditions (test fluid, pressure, duration and how leakage is counted), and those conditions differ between standards and between isolation and control valves.</p><h2>Isolation valves: API 598, ISO 5208 and EN 12266-1</h2><p>API 598 covers shell, backseat and seat tests for gate, globe, check, ball, plug and butterfly valves. For soft-seated valves it requires no visible leakage during the seat test; for metal-seated valves it allows a small number of drops or bubbles per minute that depends on valve size. ISO 5208, and EN 12266-1 which follows the same approach, defines leakage rates A to G, where rate A means no visible leakage and later letters allow progressively more. The purchaser names the rate in the order.</p><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Standard</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Applies to</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">How leakage is stated</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">API 598</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Industrial isolation valves; referenced by many API valve standards</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">No visible leakage for soft seats; drops or bubbles per minute by size for metal seats</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">ISO 5208 / EN 12266-1</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Industrial valves in general</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Leakage rates A (none visible) to G, chosen by the purchaser</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">API 6D</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Pipeline valves</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Its own seat test, with ISO 5208 rate A for soft seats and stated rates for metal seats</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">ANSI/FCI 70-2 (IEC 60534-4)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Control valves</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Classes II to VI, as a fraction of rated capacity or a measured flow</td></tr></tbody></table><h2>Control valves: ANSI/FCI 70-2 classes</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Class</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Typical seat</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Allowable leakage (summary)</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">II</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Double-port or balanced metal seat</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">0.5 per cent of rated capacity</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">III</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Balanced metal seat with a closer fit</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">0.1 per cent of rated capacity</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">IV</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Single-port or balanced metal seat</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">0.01 per cent of rated capacity</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">V</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Metal seat for tight shut-off</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">5 x 10<sup>-4</sup> ml of water per minute, per inch of port diameter, per psi of differential pressure</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">VI</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Soft seat or special metal seat</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">A small number of air bubbles per minute, set by port size</td></tr></tbody></table><p>Class IV is the usual default for metal-seated globe valves. Class V or VI is specified where the valve must also isolate, for example on letdown or vent service. Tighter classes need more seating force, so the actuator must be sized for it, as covered in <a href="https://www.btc-ksa.com/Knowledge-Hub/post/quarter-turn-valve-actuator-sizing-saudi-arabia">actuator sizing</a>.</p><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/nakakita-main-steam-isolation-valve-gear-operated.webp" alt="Gear-operated isolation valve for thermal power plants" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>How to specify and verify</h2><ul><li><p>Name the standard and the class or rate on the data sheet, with the test direction for bidirectional valves.</p></li><li><p>State whether the test is with water or air and at what pressure; low-pressure gas tests find leaks that water tests miss.</p></li><li><p>Witness the seat test at the factory or at the BTGC service center for critical valves, and keep the record.</p></li><li><p>Expect leakage in service to rise as seats wear or deposits form; a valve that passed at the factory will not stay tight in dirty or erosive service without maintenance.</p></li></ul><h2>When a valve starts passing</h2><p>A passing isolation or control valve wastes product, erodes its own seat further and can make maintenance isolation unsafe. Seat lapping, new soft seats or new trim restore tightness, and the valve is retested to its original class. The <a href="https://www.btc-ksa.com/btgc-jubail-service-center">BTGC service center in Jubail</a> repairs and retests valves of all makes; see also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/safety-relief-valve-testing-recertification-saudi-arabia">safety relief valve testing</a> for the separate API 527 rules on PSV seat tightness.</p><h2>Nakakita from BTGC</h2><p>Nakakita Seisakusho supplies automatic control valves, butterfly valves, safety valves and remote control systems. BTGC is the <a href="https://www.btc-ksa.com/nakakita-saudi-arabia">Nakakita partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/butterfly-valve-types-concentric-double-triple-offset-saudi-arabia">butterfly valve types</a> and the <a href="https://www.btc-ksa.com/flow-control-valves-solutions">flow control and valves</a> page.</p><h2>Questions buyers ask</h2><p><strong>Is Class VI the same as zero leakage?</strong> No. Class VI allows a small number of bubbles per minute during the test; it is very tight but not zero.</p><p><strong>Can a metal-seated control valve meet Class V?</strong> Yes, with a suitable trim design and enough seating force; Class VI usually needs a soft seat or a special metal seat design.</p><p><strong>Which standard applies to our valve?</strong> It depends on valve type and service; the data sheet or project specification should name it, and BTGC confirms it in the offer.</p><h2>Contact the BTGC valve team</h2><p>Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Mon, 16 Nov 2026 10:27:31 +0300</pubDate></item></channel></rss>