<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/gas-plants/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #gas plants</title><description>BTGC - Knowledge Hub #gas plants</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/gas-plants</link><lastBuildDate>Wed, 18 Nov 2026 05:59:22 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Compressor Anti-Surge Valves in Gas Plants: Speed, Capacity and Noise]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/compressor-anti-surge-valves-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/koso-severe-service-control-butterfly-valves.webp"/>What an anti-surge valve must do to protect a centrifugal compressor, how to size it, make it fast and keep noise down, and how to test it. KOSO from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_CqMEPtZYSc6WUSKSyRk9SA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_Vm5BuNKpRU6D-regqBPIFw" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_R_W4ptPhR5G4edveIs8tWg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_GbWp2aAUipPM9rhem8PjPQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> centrifugal compressors surge when flow falls too low for the pressure ratio: flow reverses through the machine, shaking the rotor, bearings and seals. The anti-surge control valve recycles gas from discharge back to suction to keep the compressor away from surge. It must open very fast, pass a large flow at high pressure drop without excessive noise, and position accurately so normal recycle does not waste energy. Choosing and testing it correctly is central to compressor protection. BTGC supplies KOSO severe service and anti-surge control valves.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/koso-severe-service-control-butterfly-valves.webp" alt="KOSO severe service control valves" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Gas plants, gas-oil separation plants, refineries and petrochemical complexes in the Kingdom run many large centrifugal compressors for gas gathering, export, refrigeration and recycle gas. A single surge event can damage seals and bearings; repeated surge can destroy a compressor.</p><h2>What the anti-surge valve must do</h2><ul><li><p>Open fully within a very short time, often one to two seconds, when the controller detects approach to surge.</p></li><li><p>Pass the full recycle flow needed at the worst case, typically at start-up or emergency shutdown.</p></li><li><p>Throttle smoothly and accurately during normal recycle control.</p></li><li><p>Handle a high pressure drop with acceptable noise and vibration.</p></li><li><p>Fail open on loss of air or signal.</p></li></ul><h2>Design features</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Feature</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Purpose</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Low-noise, multi-stage trim</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Keeps noise and pipe vibration within limits at high pressure drop; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-cavitation-noise-high-pressure-drop-saudi-arabia">noise in control valves</a></td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">High-capacity body</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Large Cv for full recycle flow</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Fast actuator with boosters and quick exhaust valves</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Achieves short opening times on large actuators</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Accurate digital positioner</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Fine control during normal operation and diagnostics</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Spring-return fail-open actuator</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Opens on loss of supply for compressor safety</td></tr></tbody></table><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/pipeline-gosp-oil-gas-saudi-arabia.webp" alt="Gas gathering and compression facility" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Sizing and testing</h2><ul><li><p>Size from compressor performance maps, using all operating cases, start-up and emergency shutdown, not only the design point.</p></li><li><p>Check the full recycle loop: cooler, piping volume and check valve affect how quickly surge can be prevented.</p></li><li><p>Measure stroke times in both directions at commissioning and after maintenance.</p></li><li><p>Test step response and overshoot with the anti-surge controller.</p></li><li><p>Trend positioner diagnostics to spot friction and air supply problems early.</p></li></ul><h2>KOSO from BTGC</h2><p>Nihon KOSO makes severe service control valves, anti-surge valves, high-performance butterfly valves, actuators and positioners. BTGC is the <a href="https://www.btc-ksa.com/koso-saudi-arabia">KOSO partner in Saudi Arabia</a>, with valve testing and repair at the Jubail service center. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/turbo-compressors-plant-air-air-separation-saudi-arabia">turbo compressors</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-sizing-cv-rangeability-saudi-arabia">control valve sizing</a> and the <a href="https://www.btc-ksa.com/oil-gas">oil and gas sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Can a standard globe valve be used for anti-surge?</strong> Only if it meets the speed, capacity and noise requirements; many standard valves do not.</p><p><strong>Why does the anti-surge valve need to be so fast?</strong> Surge can develop within a fraction of a second after a trip; the valve must open before flow collapses.</p><p><strong>Does BTGC test anti-surge valves?</strong> Yes, including stroke time and response tests at the Jubail service center.</p><h2>Contact the BTGC valve team</h2><p>Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 12:34:05 +0300</pubDate></item></channel></rss>