<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/gaskets/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #gaskets</title><description>BTGC - Knowledge Hub #gaskets</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/gaskets</link><lastBuildDate>Wed, 18 Nov 2026 11:16:20 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Gasketed Plate Heat Exchanger Maintenance: Gaskets, Cleaning and Reassembly]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/gasketed-plate-heat-exchanger-maintenance-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/kelvion-gasketed-plate-heat-exchanger.webp"/>How to open, clean, regasket and reassemble a gasketed plate heat exchanger, choose gasket materials and avoid leaks. Kelvion plate heat exchangers from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_YfsdJM6xT8mR2jQjNn-fHQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_biH2tIT-R9uGE26b0nEnLg" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_5G4W_hJsQKimFWvc5U2nlA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_mDj9jldcCtusHBdiN8i2AQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> gasketed plate heat exchangers pack a lot of surface into a small frame and can be opened for cleaning, but their gaskets and thin plates need careful handling. Most leaks and failures come from ageing or unsuitable gaskets, uneven tightening, plates hung in the wrong order and deposits left behind after cleaning. A disciplined procedure, the right gasket material and good records keep them tight for years. BTGC supplies Kelvion plate heat exchangers, spare plates and gaskets, and arranges Kelvion service.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/kelvion-gasketed-plate-heat-exchanger.webp" alt="Kelvion gasketed plate heat exchanger" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Plate heat exchangers are common in Saudi plants on closed cooling water, seawater-cooled loops, lube oil coolers, HVAC and district cooling, and water and food applications. They are efficient because the corrugated plates create turbulence at low velocities, but the same narrow channels can block, and every plate carries a gasket that ages with temperature and chemistry.</p><h2>Choosing gasket materials</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Material</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Typical use</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Limits</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">EPDM</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Water, steam condensate, many chemicals</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Not for oils and hydrocarbons</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">NBR (nitrile)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Oils, fuels and fats</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Lower temperature limit than EPDM; not for some oxidising chemicals</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">HNBR</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Oils at higher temperatures</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Higher cost</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">FKM (fluoroelastomer)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Aggressive chemicals, hot oils and acids</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Higher cost; not ideal for hot water or steam</td></tr></tbody></table><p>Temperature limits depend on the exact compound and the gasket maker's data, so the material is confirmed for the real maximum temperature and for any cleaning chemicals, not just the main process fluid.</p><h2>A good maintenance routine</h2><ul><li><p><strong>Before opening.</strong> Record the tightening dimension between the frame and pressure plates, mark the plate pack with a diagonal line so the order can be checked, and drain and cool the unit.</p></li><li><p><strong>Opening.</strong> Loosen the tightening bolts evenly in the specified sequence so the pressure plate stays parallel.</p></li><li><p><strong>Inspection.</strong> Check each plate for cracks, holes and corrosion, especially at the ports and in crevices under gaskets; dye penetrant testing finds cracks that cannot be seen.</p></li><li><p><strong>Cleaning.</strong> Clean plates with soft brushes and compatible chemicals; avoid steel wire brushes, and chloride-containing cleaners on stainless steel.</p></li><li><p><strong>Regasketing.</strong> Replace gaskets as a set when they are hard, flattened or cracked, using the correct type for the plate model; clip-on gaskets avoid glue but must be fully seated.</p></li><li><p><strong>Reassembly.</strong> Hang plates in the correct order and orientation, then tighten evenly to the recorded or specified dimension, never beyond the minimum.</p></li><li><p><strong>Testing.</strong> Pressure test each side separately and check for leaks between channels before returning the unit to service.</p></li></ul><h2>When gaskets are the problem</h2><p>If temperature, pressure or chemistry is beyond what elastomer gaskets tolerate, a semi-welded design, with plates welded in pairs and gaskets only on one side, or a fully welded plate exchanger removes gaskets from the difficult side. These designs keep much of the compactness of a plate exchanger while handling harsher duties, as discussed in <a href="https://www.btc-ksa.com/Knowledge-Hub/post/plate-vs-shell-and-tube-heat-exchanger-saudi-arabia">plate versus shell and tube heat exchangers</a>.</p><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/kelvion-welded-plate-heat-exchanger.webp" alt="Kelvion welded plate heat exchanger" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Seawater and fouling</h2><p>On seawater duties titanium plates are usual, and fouling from silt and marine growth is the main reason for opening the unit. Good intake screening and strainers upstream, as described in <a href="https://www.btc-ksa.com/Knowledge-Hub/post/passive-intake-screens-seawater-saudi-arabia">passive intake screens</a>, extend the interval between cleanings. Material choices for seawater are covered in <a href="https://www.btc-ksa.com/Knowledge-Hub/post/seawater-heat-exchanger-materials-saudi-arabia">seawater-cooled heat exchangers</a>.</p><h2>Kelvion from BTGC</h2><p>Kelvion supplies gasketed, semi-welded and welded plate heat exchangers, shell and tube exchangers and air coolers, together with service including mechanical and chemical cleaning, reconditioning, regasketing and leak testing. BTGC is the <a href="https://www.btc-ksa.com/kelvion-saudi-arabia">Kelvion partner in Saudi Arabia</a> for new units, spare plates and gaskets. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/air-fin-coolers-air-cooled-heat-exchangers-saudi-arabia">air fin coolers</a> and the <a href="https://www.btc-ksa.com/process-separation">process and thermal</a> page.</p><h2>Questions buyers ask</h2><p><strong>Can we regasket the unit ourselves?</strong> Yes, with the correct gaskets and procedure. For critical units or large plate packs, a reconditioning service with cleaning and crack testing is often faster and more reliable.</p><p><strong>How do we order the right gaskets?</strong> Send the nameplate details: model, serial number and plate count. The gasket type depends on the plate model and the fluid.</p><p><strong>Why does the exchanger leak after reassembly?</strong> Usually from uneven tightening, a gasket not seated in its groove, a plate hung in the wrong position, or tightening beyond the minimum dimension that crushes the gaskets.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Mon, 16 Nov 2026 10:03:27 +0300</pubDate></item></channel></rss>