<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/harmonics/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #harmonics</title><description>BTGC - Knowledge Hub #harmonics</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/harmonics</link><lastBuildDate>Wed, 18 Nov 2026 11:16:16 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[VFD Harmonic Mitigation: Chokes, Filters and Active Front Ends]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/vfd-harmonic-mitigation-active-front-end-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/danfoss-vacon-ac-drives-range.webp"/>How to keep variable speed drive harmonics within limits: DC chokes, 12-pulse, passive filters, active filters and active front end drives, and IEEE 519. VACON.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_4HIIYYiGRq6ELncaz8hCVw" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_jrY5dBV7SiuQLv2FKNqyVw" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_uYRJUR9sR2mHUFfSL8BmaA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_ELGpsGE8OpYC2r_CzIewBg" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> a standard six-pulse drive draws current in pulses, adding harmonic currents that heat transformers and cables, disturb other equipment and can break utility limits. Mitigation ranges from simple DC chokes to 12- or 18-pulse transformers, passive and active filters, and active front end drives with near-sinusoidal input current. The right choice depends on how much of the load is on drives and the limits at the point of supply. BTGC supplies Danfoss VACON drives and options.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/danfoss-vacon-ac-drives-range.webp" alt="Danfoss VACON AC drives" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Water pumping stations, HVAC and district cooling plants, desalination and mining sites in the Kingdom often have most of their load on drives.</p><h2>Mitigation options</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Method</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Typical result</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Notes</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">DC or AC chokes</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Lower distortion than a bare drive</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Low cost; often built into drives</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">12- or 18-pulse</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Large reduction with phase-shifting transformers</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Suits large single drives</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Passive filters</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Tuned reduction of main harmonics</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Check for resonance and light-load behaviour</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Active filters</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Cancel harmonics for groups of drives</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Good for retrofits and mixed loads</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Active front end (AFE) drives</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Very low input distortion and regeneration</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Higher cost; ideal for large or regenerative loads</td></tr></tbody></table><h2>Planning the study</h2><ul><li><p>Check the share of drive load on each transformer and the short-circuit level at the point of common coupling.</p></li><li><p>Compare predicted distortion with IEEE 519 or the utility's grid code limits.</p></li><li><p>Watch for resonance with power factor capacitors, which can amplify harmonics.</p></li><li><p>Include standby generators, where harmonics are more severe.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/hd-hyundai-electric-transformer-gis.webp" alt="Plant substation feeding drive loads" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>In operation</h2><ul><li><p>Measure harmonics after commissioning and after adding drives.</p></li><li><p>Check transformer and cable temperatures in summer.</p></li><li><p>Keep filter capacitors and fans maintained.</p></li><li><p>For energy savings and heat derating, see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/vfd-pumps-fans-energy-savings-harmonics-saudi-arabia">VFDs for pumps and fans</a>.</p></li></ul><h2>Danfoss VACON from BTGC</h2><p>VACON drives, part of Danfoss Drives, include air- and liquid-cooled drives with low-harmonic and active front end options. BTGC supplies <a href="https://www.btc-ksa.com/Knowledge-Hub/post/danfoss-vacon-saudi-arabia">Danfoss VACON in Saudi Arabia</a> with options and spares. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/obsolete-drive-replacement-vfd-retrofit-saudi-arabia">drive retrofits</a> and the <a href="https://www.btc-ksa.com/electrical-power-systems-saudi-arabia">electrical and power systems</a> page.</p><h2>Questions buyers ask</h2><p><strong>Do small drives need filters?</strong> Usually not one by one, but many small drives together can exceed limits.</p><p><strong>What is an active front end?</strong> A drive input stage using switching transistors instead of diodes, giving low harmonics and the ability to regenerate.</p><p><strong>Can harmonics damage transformers?</strong> They add heating, so heavily loaded transformers may need derating or a K-rated design.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 14:24:36 +0300</pubDate></item><item><title><![CDATA[VFDs for Pumps and Fans: Energy Savings, Harmonics and Heat Derating]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/vfd-pumps-fans-energy-savings-harmonics-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/danfoss-vacon-ac-drives-range.webp"/>How variable frequency drives cut pump and fan energy, how to meet IEEE 519 harmonic limits, and how to size drives for Saudi heat. Danfoss VACON drives, BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_BqY-m47JTBaVZYK73dE0bg" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_AYRZSCgLQS-EukGVQl9zsA" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_LzS5CV2ORiGYLi5yLWqYGg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_TNAVaBIlQofgNJ1QYmkHAQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> for centrifugal pumps and fans, flow varies with speed, but power varies roughly with the cube of speed. Running at 80 percent speed instead of throttling can cut power by around half. That is why variable frequency drives (VFDs) pay back quickly on variable-flow pumps, cooling tower fans and air handling units. Drives also bring issues to manage: harmonic currents on the supply, motor insulation stress, and derating in high ambient temperatures. BTGC supplies Danfoss VACON low and medium voltage drives.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/danfoss-vacon-ac-drives-range.webp" alt="Danfoss VACON AC drives range" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Water transmission and distribution, district cooling, desalination, HVAC and process cooling are major energy users in the Kingdom. Saudi energy efficiency programmes and rising tariffs make speed control on these loads one of the clearest efficiency upgrades.</p><h2>Where the savings come from</h2><ul><li><p>Affinity laws: flow is proportional to speed, head to speed squared and power to speed cubed.</p></li><li><p>Throttling a valve or damper wastes the extra head; reducing speed removes it.</p></li><li><p>Savings are largest where the load varies widely and runs long hours; systems with high static head save less.</p></li><li><p>Soft starting reduces mechanical stress and inrush current, extending pump and motor life.</p></li></ul><h2>Harmonics and power quality</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Solution</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Typical result</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">6-pulse drive with DC or AC choke</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Basic reduction; current distortion often 30 to 45 percent</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Passive harmonic filter</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Current distortion reduced to around 5 to 10 percent</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Active front end (low harmonic drive)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Current distortion below about 5 percent; can also regenerate</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">12- or 18-pulse with phase-shifting transformer</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Common on medium voltage and large low voltage drives</td></tr></tbody></table><p>IEEE 519 sets harmonic limits at the point of common coupling, and utilities in the Kingdom may set their own requirements. A harmonic study during design avoids overheating of transformers and cables, nuisance trips and interference with other equipment.</p><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/desalination-plant-saudi-arabia.webp" alt="Desalination plant pumping station" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Installing drives in hot climates</h2><ul><li><p>Most drives are rated for 40 to 50 &deg;C; above that they must be derated or oversized, so specify the real room temperature.</p></li><li><p>Cool electrical rooms properly; heat from drives can be large at full load.</p></li><li><p>Use IP-rated enclosures and filters against dust; keep heat sinks clean.</p></li><li><p>Use motors suitable for inverter duty, and dV/dt or sine filters for long cables to protect insulation and bearings.</p></li><li><p>Check bearing currents on larger motors; insulated bearings or shaft grounding may be needed.</p></li></ul><h2>Danfoss VACON from BTGC</h2><p>Danfoss Drives supplies VACON and VLT low and medium voltage AC drives for pumps, fans, compressors and process machines. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/danfoss-vacon-saudi-arabia">Danfoss VACON partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/soft-starting-heavy-duty-motors-weg-mv-soft-starters-vs-vfds-saudi-arabia">MV soft starters or VFDs</a>, the <a href="https://www.btc-ksa.com/electrical-power-systems-saudi-arabia">electrical power systems</a> page and the <a href="https://www.btc-ksa.com/power-utilities">power and utilities sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Does a VFD always save energy?</strong> Only where the load varies. A pump running at constant full flow gains little and the drive adds small losses.</p><p><strong>Can an existing motor run on a VFD?</strong> Often yes, after checking insulation, cooling at low speed and bearing currents.</p><p><strong>Can BTGC do a savings estimate?</strong> Yes, from the duty profile, pump curves and running hours.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 10:28:32 +0300</pubDate></item></channel></rss>