<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/hazardous-areas/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #hazardous areas</title><description>BTGC - Knowledge Hub #hazardous areas</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/hazardous-areas</link><lastBuildDate>Wed, 18 Nov 2026 11:17:08 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Encoders for Hazardous Areas: Explosion-Protected Feedback]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/explosion-proof-encoders-hazardous-areas-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/tr-electronic-rotary-linear-encoders.webp"/>How to choose encoders for Zone 1, Zone 2 and dust zones: protection types, certification, cable entries and installation on drives and valves. TR Electronic.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_-GovUSZDTkS2E5bR3lUu5w" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_Jh018tBiTPS32p4YQpIg6g" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_zoFMIQF2THuT7nf4mmQO3w" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_IQpHkJubD5qJXPvf7jJ5Hg" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> encoders give speed and position feedback on motors, cranes, winches, valves and loading arms. In oil, gas and chemical plants many of these sit in hazardous areas, so the encoder must carry the right explosion protection, usually flameproof (Ex d) or intrinsically safe (Ex i), certified for the zone, gas group and temperature class. Cable entries and installation must keep that protection intact. BTGC supplies TR Electronic encoders.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/tr-electronic-rotary-linear-encoders.webp" alt="TR Electronic rotary and linear encoders" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Refineries, gas plants, terminals and offshore facilities in the Kingdom use encoders on drives, hoists and positioning systems in classified areas.</p><h2>Protection types</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Type</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">How it works</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Notes</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Flameproof (Ex d)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Housing contains any internal explosion</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Robust; cable entries and joints must be correct</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Intrinsic safety (Ex i)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Energy kept too low to ignite gas</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Needs barriers or isolators in the safe area</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Increased safety and enclosure types</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Prevent sparks and hot surfaces</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Used for some components and terminal boxes</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Dust protection (Ex t)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Enclosure keeps dust out</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">For dust zones such as powder handling</td></tr></tbody></table><h2>What to specify</h2><ul><li><p>Zone (0, 1, 2 or 20, 21, 22), gas group and temperature class from the area classification.</p></li><li><p>Certification scheme accepted by the owner, such as IECEx or ATEX, and any local approvals.</p></li><li><p>Interface and resolution needed by the drive or PLC; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/encoder-interfaces-ssi-profinet-saudi-arabia">encoder interfaces</a>.</p></li><li><p>Ambient temperature range, since many sites see more than 50 °C in sun.</p></li><li><p>Shaft or hollow-shaft mounting and coupling to the machine.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/oil-gas-facility-saudi-arabia.webp" alt="Oil and gas facility with hazardous areas" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Installation and upkeep</h2><ul><li><p>Use certified cable glands and keep flamepaths clean and undamaged.</p></li><li><p>Do not open flameproof housings live, and never modify certified equipment.</p></li><li><p>Inspect to the plant's hazardous area inspection scheme.</p></li><li><p>Choose absolute or incremental to suit the duty; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/absolute-incremental-encoders-cranes-mills-drives-saudi-arabia">absolute or incremental</a>.</p></li><li><p>Related equipment: <a href="https://www.btc-ksa.com/Knowledge-Hub/post/explosion-proof-motors-hazardous-area-saudi-arabia">explosion-proof motors</a> and <a href="https://www.btc-ksa.com/Knowledge-Hub/post/hazardous-area-plugs-sockets-saudi-arabia">hazardous area plugs</a>.</p></li></ul><h2>TR Electronic from BTGC</h2><p>TR-Electronic makes rotary and linear encoders with a wide choice of interfaces and housings. BTGC supplies <a href="https://www.btc-ksa.com/Knowledge-Hub/post/tr-electronic-saudi-arabia">TR Electronic in Saudi Arabia</a>; send the area classification and BTGC will propose the matching certified version. See also the <a href="https://www.btc-ksa.com/oil-gas">oil and gas sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Can a standard encoder be put in a protective box?</strong> Only if the box and assembly are certified as a whole; a home-made enclosure is not acceptable.</p><p><strong>Which is better, Ex d or Ex i?</strong> Both are safe when certified; Ex i needs barriers, Ex d needs careful cable entry.</p><p><strong>Does BTGC supply replacements for installed encoders?</strong> Yes, send the nameplate and certification details.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 14:21:59 +0300</pubDate></item><item><title><![CDATA[Signalling Devices in Industrial Plants: Beacons, Sounders and Alarm Visibility]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/industrial-signalling-beacons-sounders-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/pfannenberg-enclosure-cooling-units.webp"/>How to choose and place beacons, sounders and combined signals so alarms are seen and heard in noisy, bright and hazardous plant areas. Pfannenberg from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_Rt_dQtYWS_q7IPpCyJfuNg" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_TOtBxd-VTtG27VIsYTd1cA" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_2M97maRtSKigy8Uyo-lL0g" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_t5D7Muquog-ehY4vUI1LFQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> in an emergency, alarms only work if people notice them. Plants are noisy, outdoor areas in the Kingdom are extremely bright, and workers wear hearing protection, so sounders and beacons must be chosen and placed carefully. Sound level above background noise, distinct tones, light output visible in daylight, coverage maps and hazardous area certification all matter. BTGC supplies Pfannenberg sounders, beacons and combined signalling devices.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/pfannenberg-enclosure-cooling-units.webp" alt="Pfannenberg electrical products" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Refineries, gas plants, power stations, warehouses and factories in the Kingdom rely on audible and visual alarms for fire, gas, evacuation and process warnings. Many sites have gaps where alarms are hard to see or hear.</p><h2>Key design points</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Point</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Guidance</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Sound level</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Clearly above background noise in each area</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Tones</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Distinct tones for different alarms, consistent across the site</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Visual signals</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Bright enough to be seen in daylight and by people with hearing protection</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Coverage</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Plan devices with coverage maps rather than by guesswork</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Hazardous areas</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Certified devices for the zone and gas group</td></tr></tbody></table><h2>Practical tips</h2><ul><li><p>Survey noise levels before designing sounder layout.</p></li><li><p>Use combined sounder and beacon units where people may not hear alarms.</p></li><li><p>Avoid placing beacons where they are hidden by equipment or direct sunlight.</p></li><li><p>Use colours consistently, for example for fire, gas and process alarms.</p></li><li><p>Coordinate with the fire and gas and control systems for alarm logic.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/gas-cracker-plant-saudi-arabia.webp" alt="Process plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Testing and maintenance</h2><ul><li><p>Test alarms regularly and confirm coverage after layout changes.</p></li><li><p>Check device housings, seals and mountings for damage from heat and dust.</p></li><li><p>Replace devices that have faded lenses or weak output.</p></li><li><p>Record tests and faults in the maintenance system.</p></li></ul><h2>Pfannenberg from BTGC</h2><p>Pfannenberg of Germany makes signalling devices, enclosure cooling units, filter fans and process chillers. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/pfannenberg-saudi-arabia">Pfannenberg partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/enclosure-cooling-electrical-panels-saudi-arabia">enclosure cooling</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/dc-battery-systems-oil-gas-facilities-saudi-arabia">DC systems for fire and gas</a> and the <a href="https://www.btc-ksa.com/electrical-power-systems-saudi-arabia">electrical power systems</a> page.</p><h2>Questions buyers ask</h2><p><strong>How loud should an alarm sounder be?</strong> Clearly louder than background noise in the area; designers often aim well above it.</p><p><strong>Why add beacons to sounders?</strong> People wearing hearing protection or in very noisy areas may not hear sounders.</p><p><strong>Does BTGC supply hazardous area signals?</strong> Yes, Pfannenberg certified sounders and beacons.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 16:33:10 +0300</pubDate></item><item><title><![CDATA[Control and Instrumentation Cables: Screening, Armour and Hazardous Areas]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/control-instrumentation-cables-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/bahra-electric-power-cables.webp"/>How to choose control and instrumentation cables: pairs, screening against noise, armour, fire performance and hazardous areas. Bahra Electric.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_JrOB01zJR7uOTktJyvQesA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_WOEhYioJSO6fAmmj6NefwA" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_Hn5EZzuCRja4S9dkO19IdA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_JUEJdtgXwD7FcAs-kjmAaw" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> instrumentation cables carry the small signals from transmitters, analysers and switches to control and safety systems, while control cables carry commands to valves, motors and alarms. Noise from power cables and drives can corrupt signals, fire can destroy cables that safety systems depend on, and hazardous areas add their own rules. The right construction, screening, armour, fire performance and routing protect signal quality and safety. BTGC supplies Bahra Electric control and instrumentation cables made in the Kingdom.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/bahra-electric-power-cables.webp" alt="Bahra Electric cables" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Refineries, gas plants, petrochemical complexes and power stations in the Kingdom use thousands of kilometres of control and instrumentation cable. Signal problems and cable failures are often hard to trace.</p><h2>Construction choices</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Element</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Options</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Conductors</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Twisted pairs or triads for analogue signals; multicore for control</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Screening</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Individual and overall screens to reduce electrical noise</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Armour</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Steel wire or braid for mechanical protection in buried and exposed runs</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Sheath</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">PVC, LSZH or other materials depending on fire and environmental needs</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Fire performance</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Flame-retardant or fire-resistant cables for safety circuits that must keep working in a fire</td></tr></tbody></table><h2>Avoiding signal problems</h2><ul><li><p>Separate instrument cables from power and drive cables in trays and routes.</p></li><li><p>Earth screens at one end, usually the control room, unless the system design says otherwise.</p></li><li><p>Use twisted pairs for analogue signals to cancel noise.</p></li><li><p>Choose suitable cables for fieldbus and data networks.</p></li><li><p>Keep junction boxes sealed against dust and moisture.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/process-piping-petrochemical-plant.webp" alt="Process plant with cable routes" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Hazardous areas and safety circuits</h2><ul><li><p>Follow the area classification and cable rules for intrinsically safe and other protection methods.</p></li><li><p>Use blue-sheathed or clearly identified cables for intrinsically safe circuits where required.</p></li><li><p>Use fire-resistant cables for emergency shutdown and fire and gas circuits where specified.</p></li><li><p>Use certified cable glands matched to the cable type.</p></li><li><p>Record cable schedules and test results for future maintenance.</p></li></ul><h2>Bahra Electric from BTGC</h2><p>Bahra Electric is a Saudi manufacturer of power, control and instrumentation cables and busways. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/bahra-electric-saudi-arabia">Bahra Electric partner</a> for plants and projects. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/medium-voltage-power-cables-selection-saudi-arabia">medium voltage cables</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/busway-busbar-trunking-vs-cables-saudi-arabia">busways</a> and the <a href="https://www.btc-ksa.com/electrical-power-systems-saudi-arabia">electrical power systems</a> page.</p><h2>Questions buyers ask</h2><p><strong>Why use individually screened pairs?</strong> They reduce crosstalk and noise between signals in the same cable.</p><p><strong>Where are fire-resistant cables needed?</strong> For circuits that must keep working during a fire, such as some shutdown and fire and gas systems.</p><p><strong>Does BTGC supply locally made instrumentation cables?</strong> Yes, through Bahra Electric.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 16:21:15 +0300</pubDate></item><item><title><![CDATA[DC Battery Systems for Oil and Gas Facilities: ESD, Fire and Gas, Telecom]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/dc-battery-systems-oil-gas-facilities-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/hoppecke-fnc-nickel-cadmium-batteries.webp"/>How to design DC battery systems for oil and gas facilities: loads, autonomy, NiCd or VRLA, hazardous areas, remote sites and testing. Hoppecke from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_NSHjr9PYTHSNTQcHnoi5DQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_QUsNo1MdQNuH-_EcyG_YEw" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_ForDZMYjQKGKoERgERM-Kg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_W8lNrTUw2xbGlJPcNFKotQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> when main power fails at an oil or gas facility, batteries keep the most important systems alive: emergency shutdown, fire and gas detection, control systems, telecom and emergency lighting. Their autonomy must be enough for a safe shutdown or until power returns, in remote desert sites with extreme heat. Choosing battery chemistry, sizing for the real duty cycle and testing regularly are the basis of a reliable DC system. BTGC supplies Hoppecke nickel-cadmium and lead-acid batteries.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/hoppecke-fnc-nickel-cadmium-batteries.webp" alt="Hoppecke nickel-cadmium batteries" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Gas-oil separation plants, wellhead sites, pipeline stations and offshore platforms in the Kingdom often operate unmanned and far from towns. A battery system that fails during a power outage can prevent a safe shutdown.</p><h2>Typical DC loads</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">System</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Notes</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Emergency shutdown (ESD) and fire and gas</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Safety-critical; autonomy set by safety studies</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Distributed control and SCADA</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Keeps monitoring and control during outages</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Switchgear tripping and closing</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Short high-current loads</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Telecom and radio</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Often 48 V systems at remote sites</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Emergency lighting</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Escape and critical area lighting</td></tr></tbody></table><h2>Design points</h2><ul><li><p>Build a duty cycle from all loads with their durations; size to IEEE 1115 for NiCd or IEEE 485 for lead-acid.</p></li><li><p>Apply temperature and ageing factors; heat is the main threat in the Kingdom, see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/substation-ups-batteries-high-temperature-nicd-lead-acid-saudi-arabia">batteries in Saudi heat</a>.</p></li><li><p>Choose NiCd where rooms are hot, maintenance visits are rare or deep discharges may occur.</p></li><li><p>Follow hazardous area and ventilation rules for battery rooms and enclosures.</p></li><li><p>At remote sites, combine batteries with solar charging and size for several days of autonomy where needed.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/pipeline-gosp-oil-gas-saudi-arabia.webp" alt="Oil and gas facility" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Testing and upkeep</h2><ul><li><p>Check float voltages, electrolyte levels and connections on each visit.</p></li><li><p>Carry out capacity tests at commissioning and at set intervals.</p></li><li><p>Monitor battery temperature and cell voltages remotely at unmanned sites.</p></li><li><p>Keep charger alarms connected to the control system.</p></li><li><p>Replace strings as a whole when capacity falls below the design limit.</p></li></ul><h2>Hoppecke from BTGC</h2><p>Hoppecke of Germany makes industrial nickel-cadmium and lead-acid batteries for oil and gas, utilities, telecom and rail. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/hoppecke-saudi-arabia">Hoppecke partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/hipps-high-integrity-pressure-protection-saudi-arabia">HIPPS</a> and the <a href="https://www.btc-ksa.com/oil-gas">oil and gas sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>How long should ESD batteries last during an outage?</strong> As long as the safety study requires for a safe shutdown; this is set project by project.</p><p><strong>Are NiCd batteries suitable for solar-charged remote sites?</strong> Yes, they handle high temperatures and deep cycling well.</p><p><strong>Does BTGC supply complete battery racks?</strong> Yes, with racks, connectors and monitoring on request.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 12:42:46 +0300</pubDate></item></channel></rss>