<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/hvac/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #HVAC</title><description>BTGC - Knowledge Hub #HVAC</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/hvac</link><lastBuildDate>Wed, 18 Nov 2026 05:39:34 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Valves for District Cooling Networks]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/district-cooling-network-valves-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/itag-avk-saudi-made-valves-hydrant.webp"/>Which valves district cooling plants and chilled water networks need: butterfly, gate, air, drain and balancing valves, plus upkeep tips. AVK from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_FYfjgOV8S0KW5_tODyaERg" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_f_zoYePqRXe0ZtYAwRm1dg" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_WPtF0P-NTqWwx_SyfqM_JA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_54oX76VZbZzzoKy9-2OFeg" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> district cooling plants make chilled water centrally and pump it through buried networks to buildings, which is common for large developments in the Kingdom. The network needs isolation valves for sections and branches, air valves at high points, drain valves at low points, and control or balancing valves at energy transfer stations. Valves must stay tight with low leakage for decades, because chilled water losses cost energy and water treatment chemicals. BTGC supplies AVK and AVK SVMC valves for water networks.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/itag-avk-saudi-made-valves-hydrant.webp" alt="AVK valves made in Saudi Arabia" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>New cities, airports, campuses and mixed-use developments in the Kingdom increasingly use district cooling to cut electricity use. Network reliability depends on valves that are easy to find, operate and maintain.</p><h2>Valves in a district cooling network</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Location</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Typical valve</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Plant headers and large mains</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Butterfly valves with gearboxes or actuators</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Branch and building connections</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Resilient-seated gate or butterfly valves</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">High points</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Air release and vacuum valves</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Low points</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Drain valves</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Energy transfer stations</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Control and balancing valves</td></tr></tbody></table><h2>Selection points</h2><ul><li><p>Pressure rating including surge; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/non-slam-check-valves-water-hammer-saudi-arabia">water hammer</a>.</p></li><li><p>Epoxy coating inside and out and stainless steel stems and bolts for long life underground.</p></li><li><p>Insulation and anti-condensation measures for valve chambers.</p></li><li><p>Low-leakage seats so isolated sections hold during repairs.</p></li><li><p>Access chambers sized for operation and maintenance.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/bac-cooling-towers-rooftop-installation.webp" alt="Cooling plant serving a district cooling network" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Operation and maintenance</h2><ul><li><p>Exercise isolation valves regularly and record turns.</p></li><li><p>Check air valves; trapped air reduces flow and raises pumping energy.</p></li><li><p>Inspect chambers for water ingress and corrosion.</p></li><li><p>Keep valve positions and locations in the network GIS.</p></li><li><p>Coordinate valve work with water treatment to avoid contamination.</p></li></ul><h2>AVK from BTGC</h2><p>AVK of Denmark makes valves, hydrants and fittings for water, wastewater and gas; AVK SVMC manufactures in the Kingdom. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/avk-saudi-arabia">AVK partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/water-network-valves-hydrants-awwa-c504-saudi-arabia">water network valves</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/refrigeration-compressor-oils-chillers-saudi-arabia">chiller compressor oils</a> and the <a href="https://www.btc-ksa.com/power-utilities">power and utilities sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Why do district cooling networks need air valves?</strong> Air pockets reduce flow and cause noise and corrosion; air valves release them at high points.</p><p><strong>Butterfly or gate valves for chilled water?</strong> Butterfly valves suit large mains; gate valves are common on smaller branches.</p><p><strong>Does BTGC supply locally made valves?</strong> Yes, through AVK SVMC in the Kingdom.</p><h2>Contact the BTGC valve team</h2><p>Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 15:15:18 +0300</pubDate></item><item><title><![CDATA[Refrigeration Compressor Oils for Chillers and District Cooling: POE, Mineral and PAG]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/refrigeration-compressor-oils-chillers-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/bac-cooling-towers-rooftop-installation.webp"/>How to choose refrigeration compressor oil for chillers and district cooling: matching refrigerant, viscosity, moisture control and oil analysis. Calumet, BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_tKwm_J_ORT-16h9YiaXGfg" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_l2xbUsMIQHuKDK8wO5ho7w" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_pPbVXaIOSWmd1hyPksnXeg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_xFDbuFmITgHfr4G2vzq-gg" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> chillers and refrigeration compressors depend on an oil that mixes correctly with the refrigerant, keeps its viscosity under refrigerant dilution and stays dry. Modern HFC and HFO refrigerants usually need polyol ester (POE) oils, older HCFC systems and ammonia often use mineral or alkylbenzene oils, and some systems use PAG oils. Using the wrong oil, or letting moisture in, leads to poor oil return, acid formation and compressor failure. BTGC supplies Calumet specialty oils and ester base stocks.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/bac-cooling-towers-rooftop-installation.webp" alt="Cooling towers serving a chiller plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Air conditioning and district cooling take a large share of electricity in the Kingdom, and chillers run for long hours under high condensing temperatures. Compressor reliability directly affects comfort, process cooling and energy use.</p><h2>Matching oil to refrigerant</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Refrigerant type</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Typical oil</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">HFC and HFO refrigerants</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Polyol ester (POE) oils</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Older HCFC systems</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Mineral or alkylbenzene oils</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Ammonia</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Mineral or synthetic oils approved for ammonia</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">CO2 and some special systems</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">POE or PAG oils as specified by the compressor maker</td></tr></tbody></table><p>Always follow the compressor maker's approved oil list; viscosity grade and approvals matter as much as oil type.</p><h2>Moisture and contamination</h2><ul><li><p>POE oils absorb moisture from air quickly; keep containers sealed and use them soon after opening.</p></li><li><p>Moisture reacts with POE and refrigerant to form acids that attack motors and bearings.</p></li><li><p>Use filter driers and check moisture indicators regularly.</p></li><li><p>Avoid mixing oil types during retrofits without a planned flushing procedure.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/industrial-cooling-towers-plant.webp" alt="Industrial cooling plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Oil analysis and maintenance</h2><ul><li><p>Sample oil at regular intervals for acidity, moisture, viscosity and wear metals.</p></li><li><p>Change oil and filter driers when results show acid or moisture rising.</p></li><li><p>Check oil return and levels, especially at low load and in long piping systems.</p></li><li><p>Keep high condensing pressures under control by cleaning condensers and cooling towers; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/cooling-tower-performance-loss-recovery-saudi-arabia">cooling tower performance</a>.</p></li></ul><h2>Calumet from BTGC</h2><p>Calumet is a US specialty refiner of naphthenic oils, white oils, solvents, esters and lubricants, and the parent of the Royal Purple and Bel-Ray brands. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/calumet-saudi-arabia">Calumet partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/evaporative-condensers-ammonia-refrigeration-saudi-arabia">evaporative condensers for ammonia refrigeration</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/synthetic-compressor-oil-hot-climate-saudi-arabia">compressor oil in hot climates</a> and the <a href="https://www.btc-ksa.com/power-utilities">power and utilities sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Can mineral oil be used with HFC refrigerants?</strong> Generally no; HFCs do not mix well with mineral oil, so oil return suffers. POE is normally used.</p><p><strong>Why is POE oil sensitive to moisture?</strong> It absorbs water readily, which can hydrolyse the oil and form acids.</p><p><strong>Does BTGC supply oil analysis?</strong> Yes, sampling and analysis can be arranged with oil supply.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 14:12:57 +0300</pubDate></item></channel></rss>