<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/iecex/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #IECEx</title><description>BTGC - Knowledge Hub #IECEx</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/iecex</link><lastBuildDate>Wed, 18 Nov 2026 11:16:26 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Encoders for Hazardous Areas: Explosion-Protected Feedback]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/explosion-proof-encoders-hazardous-areas-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/tr-electronic-rotary-linear-encoders.webp"/>How to choose encoders for Zone 1, Zone 2 and dust zones: protection types, certification, cable entries and installation on drives and valves. TR Electronic.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_-GovUSZDTkS2E5bR3lUu5w" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_Jh018tBiTPS32p4YQpIg6g" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_zoFMIQF2THuT7nf4mmQO3w" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_IQpHkJubD5qJXPvf7jJ5Hg" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> encoders give speed and position feedback on motors, cranes, winches, valves and loading arms. In oil, gas and chemical plants many of these sit in hazardous areas, so the encoder must carry the right explosion protection, usually flameproof (Ex d) or intrinsically safe (Ex i), certified for the zone, gas group and temperature class. Cable entries and installation must keep that protection intact. BTGC supplies TR Electronic encoders.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/tr-electronic-rotary-linear-encoders.webp" alt="TR Electronic rotary and linear encoders" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Refineries, gas plants, terminals and offshore facilities in the Kingdom use encoders on drives, hoists and positioning systems in classified areas.</p><h2>Protection types</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Type</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">How it works</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Notes</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Flameproof (Ex d)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Housing contains any internal explosion</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Robust; cable entries and joints must be correct</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Intrinsic safety (Ex i)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Energy kept too low to ignite gas</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Needs barriers or isolators in the safe area</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Increased safety and enclosure types</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Prevent sparks and hot surfaces</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Used for some components and terminal boxes</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Dust protection (Ex t)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Enclosure keeps dust out</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">For dust zones such as powder handling</td></tr></tbody></table><h2>What to specify</h2><ul><li><p>Zone (0, 1, 2 or 20, 21, 22), gas group and temperature class from the area classification.</p></li><li><p>Certification scheme accepted by the owner, such as IECEx or ATEX, and any local approvals.</p></li><li><p>Interface and resolution needed by the drive or PLC; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/encoder-interfaces-ssi-profinet-saudi-arabia">encoder interfaces</a>.</p></li><li><p>Ambient temperature range, since many sites see more than 50 °C in sun.</p></li><li><p>Shaft or hollow-shaft mounting and coupling to the machine.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/oil-gas-facility-saudi-arabia.webp" alt="Oil and gas facility with hazardous areas" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Installation and upkeep</h2><ul><li><p>Use certified cable glands and keep flamepaths clean and undamaged.</p></li><li><p>Do not open flameproof housings live, and never modify certified equipment.</p></li><li><p>Inspect to the plant's hazardous area inspection scheme.</p></li><li><p>Choose absolute or incremental to suit the duty; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/absolute-incremental-encoders-cranes-mills-drives-saudi-arabia">absolute or incremental</a>.</p></li><li><p>Related equipment: <a href="https://www.btc-ksa.com/Knowledge-Hub/post/explosion-proof-motors-hazardous-area-saudi-arabia">explosion-proof motors</a> and <a href="https://www.btc-ksa.com/Knowledge-Hub/post/hazardous-area-plugs-sockets-saudi-arabia">hazardous area plugs</a>.</p></li></ul><h2>TR Electronic from BTGC</h2><p>TR-Electronic makes rotary and linear encoders with a wide choice of interfaces and housings. BTGC supplies <a href="https://www.btc-ksa.com/Knowledge-Hub/post/tr-electronic-saudi-arabia">TR Electronic in Saudi Arabia</a>; send the area classification and BTGC will propose the matching certified version. See also the <a href="https://www.btc-ksa.com/oil-gas">oil and gas sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Can a standard encoder be put in a protective box?</strong> Only if the box and assembly are certified as a whole; a home-made enclosure is not acceptable.</p><p><strong>Which is better, Ex d or Ex i?</strong> Both are safe when certified; Ex i needs barriers, Ex d needs careful cable entry.</p><p><strong>Does BTGC supply replacements for installed encoders?</strong> Yes, send the nameplate and certification details.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 14:21:59 +0300</pubDate></item><item><title><![CDATA[Explosion-Proof Motors for Saudi Plants: Ex d, Ex e, Ex n]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/explosion-proof-motors-hazardous-area-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/weg-high-voltage-motor-w60.webp"/>Matching Ex d, Ex e, Ex n and Ex p motors to zone, gas group and temperature class. WEG medium and high voltage motors from BTGC, the WEG approved service center.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_AEVxP1J7S66hpMAkqqKEuQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_Ypo1v81YR8uaGsQc6n2Elw" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_5eT-hqLlRomyAbNOkGHnfA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_ALBccwGsOOHtkglUSQ6H1w" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> an explosion-proof motor is defined by its certificate, not its paint. Ex d, Ex e, Ex n and Ex t motors protect against different ignition risks and are selected by zone, gas group and temperature class. BTGC supplies WEG medium and high voltage motors for hazardous areas in Saudi Arabia, with IECEx and ATEX certificates, and services them at the WEG approved service center in Jubail.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/weg-high-voltage-motor-w60.webp" alt="WEG industrial electric motor supplied by BTGC in Saudi Arabia" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Most motors in a Saudi refinery, gas plant or petrochemical complex sit inside a hazardous area. Pump and fan motors near flanges, agitators on solvent tanks, compressor auxiliaries and loading pump motors all have to be built so that a fault inside the motor cannot ignite the gas outside it. The buyer's job is to match the motor's protection concept to the area classification, and to make sure the certificate covers the exact motor that arrives.</p><h2>Protection concepts, in plain terms</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Marking</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Concept</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Typical use</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Ex db (flameproof)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">The frame contains an internal explosion and cools the escaping gas through flame paths</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Zone 1, pumps and compressors in process units</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Ex eb (increased safety)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">No arcs or hot spots in normal or defined fault conditions; strict tE time and protection relay</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Zone 1 fans and pumps where a lighter motor is wanted</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Ex ec (non-sparking)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">No ignition source in normal operation</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Zone 2, the majority of plant motors</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Ex tb / tc (dust)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Dust-tight enclosure with limited surface temperature</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Zone 21/22, sulphur, polymer powder and grain handling</td></tr></tbody></table><p>After the concept comes the gas group (IIA, IIB or IIC; hydrogen service needs IIC) and the temperature class (T3 at 200 &deg;C is the usual refinery requirement, T4 at 135 &deg;C for some solvents). A motor marked Ex db IIB T4 Gb is not acceptable where hydrogen is present, however good it is.</p><h2>Variable speed drives and Ex motors</h2><p>Running an Ex motor on a VFD changes its thermal behaviour: at low speed the shaft fan moves less air, and the drive's harmonics add losses. The certificate must state that the motor is approved for inverter duty, with the speed range, the drive type and usually a requirement for embedded thermistors wired to a certified protection relay. WEG certifies its hazardous-area motors for inverter duty where specified and supplies the embedded thermal protection, which saves an argument with the site inspector later.</p><h2>The certificate is the product</h2><p>Saudi operators accept IECEx certificates, and most also accept ATEX; SASO conformity and the operator's own vendor approval come on top. Each motor must carry a nameplate with the certificate number and the full marking, and the certificate must cover the frame size, the terminal box and any cable gland or accessory fitted. Three things BTGC checks before a motor is released to site:</p><ul><li><p>The certificate number on the nameplate matches the IECEx online register.</p></li><li><p>The gas group and temperature class meet the area classification drawing, not just the data sheet.</p></li><li><p>Cable glands and plugs carry their own Ex certification; a flameproof motor with an uncertified gland is a non-conformity.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/electric-motor-stator-rewind-btgc-jubail-workshop.webp" alt="Large electric motor stator under repair in the BTGC motor workshop in Jubail" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Repairing an Ex motor without losing the certificate</h2><p>A flameproof motor repaired in a workshop that does not control flame-path gaps is no longer flameproof. IEC 60079-19 sets the rules for repair and overhaul of Ex equipment: measured flame paths, approved winding insulation systems, documented tests and a repair plate. The BTGC service center in Jubail is the WEG approved service center in Saudi Arabia and follows the WEG repair procedures for Ex motors, so a rewound Ex motor goes back with its certification intact and a repair record the operator can file.</p><h2>WEG from BTGC</h2><p>WEG builds medium and high voltage motors for hazardous areas in flameproof (Ex db), increased-safety (Ex eb), non-sparking (Ex ec) and pressurised (Ex p) designs, with IECEx and ATEX certification and inverter-duty options. BTGC covers WEG medium and high voltage motors and drives in the Kingdom: BTGC is the <a href="https://www.btc-ksa.com/weg">WEG partner in Saudi Arabia</a> and runs the WEG approved service center in Jubail. See the <a href="https://www.btc-ksa.com/electrical-power-systems-saudi-arabia">electrical and power systems</a> page and the <a href="https://www.btc-ksa.com/oil-gas">oil and gas sector page</a>.</p><h2>Questions buyers ask</h2><p><strong>Can we fit an Ex ec motor in Zone 1 to save cost?</strong> No. Zone 1 needs Ex db or Ex eb; the area classification drawing decides, not the budget.</p><p><strong>Is a repaired Ex motor still certified?</strong> Only if the repairer works to IEC 60079-19 and documents the flame paths and winding system; ask for the repair report.</p><p><strong>What should an enquiry include?</strong> Zone, gas group, temperature class, ambient temperature (50 &deg;C in the Eastern Province is normal), duty, mounting, voltage and whether a VFD is used.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Sun, 15 Nov 2026 08:25:56 +0300</pubDate></item></channel></rss>