<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/instrument-air/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #instrument air</title><description>BTGC - Knowledge Hub #instrument air</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/instrument-air</link><lastBuildDate>Wed, 18 Nov 2026 07:01:52 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Instrument and Plant Air Quality: Dryers, Filters and ISO 8573-1 Classes]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/instrument-air-quality-dryers-iso-8573-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/ingersoll-rand-centrifugal-air-compressor.webp"/>How to get clean, dry instrument and plant air: ISO 8573-1 classes, dryer and filter choices, dew point in hot climates and monitoring. Ingersoll Rand, BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_NEOMf_zHRXmemtErT2pX8w" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_LJY6-fy7SzGi_d2jKP9pwg" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_mqu3k_GKQseNJ1F-bzTmEQ" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_D26k8TANYCWDOCs3-6LH0Q" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> control valves, positioners, actuators and analysers depend on clean, dry instrument air. Water, oil and particles in the air cause sticking positioners, corroded actuators and false trips. ISO 8573-1 defines air quality classes for particles, water (pressure dew point) and oil, and the right combination of compressor, dryer and filters delivers the required class. Hot, humid summers in the Kingdom make drying the hardest part. BTGC supplies Ingersoll Rand compressors, dryers and filters.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/ingersoll-rand-centrifugal-air-compressor.webp" alt="Ingersoll Rand air compressor" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Every refinery, petrochemical plant, gas facility and power plant in the Kingdom has an instrument air system, often backed up by plant air. Loss of instrument air can shut down a whole unit.</p><h2>ISO 8573-1 in brief</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Contaminant</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">How it is classed</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Solid particles</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">By particle count and size</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Water</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">By pressure dew point, for example minus 40 degC for a very dry class</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Oil</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">By total oil content, including vapour and aerosol</td></tr></tbody></table><h2>Dryer and filter options</h2><ul><li><p>Refrigerated dryers: economical, dew point a few degrees above zero; suitable for plant air.</p></li><li><p>Desiccant (adsorption) dryers: dew points of minus 40 degC or lower for instrument air; heatless or heated regeneration.</p></li><li><p>Heat of compression dryers: use compressor heat to regenerate desiccant on oil-free compressors.</p></li><li><p>Coalescing and particle filters before and after dryers to remove oil aerosols and dust.</p></li><li><p>Oil-free compressors avoid oil contamination at source.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/oil-gas-facility-saudi-arabia.webp" alt="Process plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Hot climate and maintenance points</h2><ul><li><p>Size dryers for summer inlet temperature and humidity, not catalogue reference conditions.</p></li><li><p>Install dew point sensors and alarm on high dew point.</p></li><li><p>Change filter elements on differential pressure and replace desiccant on schedule.</p></li><li><p>Drain condensate reliably with zero-loss drains and check them often.</p></li><li><p>Keep air receivers and headers sloped and drained.</p></li></ul><h2>Ingersoll Rand from BTGC</h2><p>Ingersoll Rand makes compressed air and gas equipment, including centrifugal and oil-free compressors, dryers and filters. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/ingersoll-rand-saudi-arabia">Ingersoll Rand partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/aeration-blowers-wastewater-treatment-saudi-arabia">aeration blowers</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/turbo-compressors-plant-air-air-separation-saudi-arabia">turbo compressors for plant air</a> and the <a href="https://www.btc-ksa.com/oil-gas">oil and gas sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>What dew point does instrument air need?</strong> Many plants specify about minus 40 degC pressure dew point, or at least well below the lowest ambient temperature.</p><p><strong>Is a refrigerated dryer enough for instrument air?</strong> Often not; desiccant dryers are usually specified for instrument air.</p><p><strong>Can BTGC audit our compressed air system?</strong> Yes, including air quality and energy use.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 14:18:01 +0300</pubDate></item></channel></rss>