<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/insulation-resistance/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #insulation resistance</title><description>BTGC - Knowledge Hub #insulation resistance</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/insulation-resistance</link><lastBuildDate>Wed, 18 Nov 2026 11:16:54 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Transformer Commissioning Tests: What to Check Before Energising]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/transformer-commissioning-tests-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/arabian-transformers-distribution-transformer.webp"/>Which tests to run before energising a transformer: oil, insulation, winding resistance, ratio, vector group, SFRA and protection. ATC, BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_PG43Dhh4QwCbEB1QFtOHFQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_XfjY5689TCi8WMsLtAgEQg" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_V4RbOC-JQ228TShshS5VCg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_pLYXiLcO3DC7uNVqvbgyJw" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> a transformer can be damaged during transport, storage or installation, and wiring or protection mistakes can cause trouble on first energising. Commissioning tests check oil quality, insulation, windings, ratio and vector group, and confirm that protection devices and controls work. They also record a baseline, such as SFRA and DGA results, that future tests are compared with. BTGC supplies Arabian Transformers Company transformers and supports their commissioning.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/arabian-transformers-distribution-transformer.webp" alt="Arabian Transformers distribution transformer" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>New substations, industrial plants, solar farms and giga-projects in the Kingdom commission large numbers of transformers. A careful first energising prevents early failures and disputes.</p><h2>Typical commissioning tests</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Test</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Checks</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Visual and mechanical</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Damage, leaks, earthing, clearances, accessories</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Oil tests</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Breakdown voltage, moisture and baseline DGA</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Insulation resistance and PI</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Overall insulation condition</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Winding resistance</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Connections and tap changer contacts</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Turns ratio and vector group</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Correct ratio on all taps and correct phase shift</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">SFRA</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Baseline for future checks of winding movement</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Protection and controls</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Buchholz, pressure relief, temperature devices, CTs and alarms</td></tr></tbody></table><h2>Before energising</h2><ul><li><p>Check transport shock recorder results for large units.</p></li><li><p>Confirm oil levels and that valves to radiators and conservator are open.</p></li><li><p>Vent air from radiators, bushings and Buchholz relay.</p></li><li><p>Check tap position and control settings.</p></li><li><p>Confirm protection settings and trip tests.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/desalination-plant-saudi-arabia.webp" alt="Utility plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>First energising and after</h2><ul><li><p>Energise with protection in service and observe for noise, heating and alarms.</p></li><li><p>Hold a soak period before loading where specified.</p></li><li><p>Take oil samples after a set period for DGA comparison; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/transformer-oil-testing-dga-saudi-arabia">oil testing and DGA</a>.</p></li><li><p>Record all results in a commissioning report.</p></li><li><p>Plan routine tests; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/transformer-protection-buchholz-pressure-relief-saudi-arabia">transformer protection</a>.</p></li></ul><h2>Arabian Transformers from BTGC</h2><p>Arabian Transformers Company (ATC) manufactures distribution and power transformers, compact substations and package units in the Kingdom. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/arabian-transformers-saudi-arabia">ATC partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/dry-type-vs-oil-immersed-transformers-saudi-arabia">dry-type vs oil-immersed transformers</a>, the <a href="https://www.btc-ksa.com/electrical-power-systems-saudi-arabia">electrical power systems</a> page and the <a href="https://www.btc-ksa.com/power-utilities">power and utilities sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Why record an SFRA baseline?</strong> Later tests can be compared with it to detect winding movement after faults or transport.</p><p><strong>Do repaired transformers need commissioning tests?</strong> Yes, the same checks apply after major repairs.</p><p><strong>Does BTGC support transformer commissioning?</strong> Yes, with ATC transformers and testing coordination.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 09:02:09 +0300</pubDate></item><item><title><![CDATA[Storing and Preserving MV Motors Before Commissioning]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/mv-motor-storage-preservation-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/weg-water-cooled-electric-motor-saudi-arabia.webp"/>How to store medium and high voltage motors on Saudi project sites: heaters, insulation resistance checks, shaft rotation and bearing care. WEG from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_HUMyqrVqQUKDlk1Ya5RPtg" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_zLcWg-G-Rrubnn0XXIMgRg" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_HLEIdt_tQkG1uGk6HKdn6Q" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_2sUWHjyPMYr0OQBDZzy8hw" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> large motors often wait months, sometimes years, between delivery and commissioning on Saudi projects. In that time dust, humidity swings, condensation and vibration from nearby work can damage windings and bearings before the motor ever runs. A preservation routine (dry, covered storage, energised space heaters, periodic insulation resistance tests, regular shaft rotation and correct bearing care) protects the motor and the warranty and avoids failures at start-up. BTGC supplies WEG MV and HV motors and supports preservation, inspection and pre-commissioning checks.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/weg-water-cooled-electric-motor-saudi-arabia.webp" alt="WEG medium voltage motor" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>On large projects, motors arrive early with the driven equipment packages and then sit on laydown yards, in partly built substations or on installed skids while construction continues. Coastal sites see high humidity at night and temperatures above 45 &deg;C by day; inland sites see dust storms. Both are hard on insulation and bearings that are not running.</p><h2>What goes wrong in storage</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Risk</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Cause</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Result</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Low insulation resistance</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Moisture absorbed by windings during humid nights, condensation</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Failed IR or PI test at commissioning, or a fault at first energisation</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">False brinelling</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Vibration from nearby equipment while the shaft is stationary</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Marked bearing races and noisy bearings from day one</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Bearing corrosion</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Condensation in bearing housings, degraded grease or oil</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Pitting and early bearing failure</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Dust and sand ingress</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Open terminal boxes, missing covers, outdoor storage</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Contaminated windings, blocked cooling passages</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Sleeve bearing damage</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Oil drained for shipping not refilled, or the shaft turned dry</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Wiped bearing surfaces</td></tr></tbody></table><h2>A practical preservation routine</h2><ul><li><p><strong>Store indoors or under cover</strong>, on a level base, away from vibration sources, with terminal boxes and openings sealed.</p></li><li><p><strong>Energise the space heaters</strong> continuously in storage and after installation until the motor runs, to keep the windings above the dew point.</p></li><li><p><strong>Measure insulation resistance and polarisation index</strong> on arrival and at regular intervals, typically monthly, and record them with the winding temperature.</p></li><li><p><strong>Rotate the shaft</strong> by hand every few weeks to a new position, to redistribute lubricant and change the loaded points in rolling bearings; refit the transport lock before moving the motor.</p></li><li><p><strong>Look after bearings and lubricant</strong>: keep sleeve bearing housings at the storage oil level the maker specifies, and regrease rolling bearings as the storage instructions require.</p></li><li><p><strong>Protect machined surfaces</strong> such as shaft ends and feet with preservative, and inspect it periodically.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/weg-high-voltage-motor-w60.webp" alt="WEG high voltage industrial motor" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Insulation resistance targets</h2><p>IEEE 43 gives the recommended minimum insulation resistance and polarisation index for rotating machines. For form-wound MV windings, the recommended minimum insulation resistance corrected to 40 &deg;C is 100 megohms, and the recommended minimum polarisation index for Class F insulation is 2.0. A falling trend in storage matters more than any single reading: it shows moisture getting in, and the winding should be dried with heaters or a controlled low-voltage current before the motor is energised.</p><h2>Before the first start</h2><ul><li><p>Review the storage records with the commissioning team and the manufacturer.</p></li><li><p>Repeat IR and PI tests, and dry the winding if the results are low.</p></li><li><p>Inspect bearings, renew grease or oil if storage has exceeded the maker's limit, and check end float.</p></li><li><p>Remove the transport lock, check alignment and soft foot, and confirm cooling paths are clear.</p></li><li><p>Run uncoupled first where the procedure allows, with vibration and temperature monitoring.</p></li></ul><h2>WEG from BTGC</h2><p>BTGC is the <a href="https://www.btc-ksa.com/weg">WEG partner in Saudi Arabia</a> for medium and high voltage motors and MV drives. The <a href="https://www.btc-ksa.com/btgc-jubail-service-center">BTGC service center in Jubail</a>, a WEG approved service center, carries out site inspections, winding drying, bearing work and pre-commissioning tests. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/preventing-stator-winding-failure-duraguard-vpi-insulation-saudi-arabia">preventing stator winding failure</a> and <a href="https://www.btc-ksa.com/Knowledge-Hub/post/vfd-bearing-currents-mv-motors-saudi-arabia">bearing currents in VFD-driven motors</a>.</p><h2>Questions buyers ask</h2><p><strong>How long can an MV motor be stored?</strong> With proper preservation, many months to years; beyond the maker's storage limit, bearings and lubricants need inspection or renewal before start-up.</p><p><strong>Should heaters stay on after installation?</strong> Yes, until the motor is in regular service, and during long stops afterwards.</p><p><strong>Can BTGC check motors stored on our site?</strong> Yes. BTGC can inspect, test and report on stored motors and carry out drying or bearing work where needed.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Mon, 16 Nov 2026 10:33:42 +0300</pubDate></item></channel></rss>