<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/iso-20816/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #ISO 20816</title><description>BTGC - Knowledge Hub #ISO 20816</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/iso-20816</link><lastBuildDate>Wed, 18 Nov 2026 11:17:03 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Vibration Analysis for Large Electric Motors: What the Spectrum Tells You]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/motor-vibration-analysis-spectrum-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/weg-high-voltage-motor-w60.webp"/>How to read vibration spectra on large motors: unbalance, misalignment, looseness, bearing defects and electrical faults at twice line frequency. WEG from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_ZhQJZSK1SEuGIe9o1SDaEQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_cI2tjuXXQzGOTFWI-8VK2g" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_Xw77Qp20Sq2lSQzsr8fmSg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_9d_S7zdmCy6JNHUPxhv1JQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> vibration is the most useful single indicator of a large motor's health. Overall levels compared with ISO 20816 zones show whether a machine is acceptable; the frequency spectrum shows why it vibrates. Mechanical faults such as unbalance, misalignment and looseness appear at running speed and its harmonics, bearing faults at their own defect frequencies, and electrical faults at twice line frequency or as sidebands. BTGC supplies WEG MV and HV motors and diagnoses and repairs motor faults at its WEG approved service center in Jubail.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/weg-high-voltage-motor-w60.webp" alt="WEG high voltage industrial motor" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Saudi plants run large motors on compressors, pumps, fans and mills, and many are monitored by portable routes or online systems. The data is only useful if someone can read it. A vibration spectrum splits the overall level into its frequency components, and each common motor fault leaves a recognisable pattern.</p><h2>Severity: how much is too much</h2><p>ISO 20816, which replaces the earlier ISO 10816 parts, sets vibration evaluation zones for industrial machines by size and support type: zone A for newly commissioned machines, B for unrestricted long-term operation, C for limited operation until there is an opportunity to repair, and D for vibration severe enough to cause damage. Trends matter as much as zones: a steady rise inside zone B is an early warning.</p><h2>Reading the spectrum</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Pattern</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Likely cause</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">High 1x running speed, mainly radial, steady phase</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Unbalance</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">High 1x and 2x, high axial vibration, phase shift across the coupling</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Misalignment</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Many harmonics of running speed, sometimes half-orders</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Mechanical looseness, or a cracked foot or base</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Non-synchronous peaks at bearing defect frequencies, with harmonics and sidebands</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Rolling bearing defects</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Sub-synchronous peak around 0.4 to 0.5x on sleeve bearings</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Oil whirl or bearing instability</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Peak at twice line frequency (120 Hz on the Saudi 60 Hz grid) that disappears the instant power is cut</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Electrical: uneven air gap, stator problems, soft foot distorting the frame</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Pole-pass sidebands around 1x and its harmonics</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Rotor bar or end ring problems</td></tr></tbody></table><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/weg-water-cooled-electric-motor-saudi-arabia.webp" alt="WEG medium voltage motor" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Separating mechanical and electrical causes</h2><p>A simple test is to watch the vibration as the motor is switched off. Electrically caused vibration at twice line frequency disappears the moment power is removed, while mechanical vibration decays with speed. An uncoupled run separates motor problems from the driven machine, and motor current signature analysis adds detail on rotor bar faults.</p><h2>Common motor-specific causes in the Kingdom</h2><ul><li><p>Soft foot and base problems after relocation or poor grouting.</p></li><li><p>Bearing damage from VFD currents, described in <a href="https://www.btc-ksa.com/Knowledge-Hub/post/vfd-bearing-currents-mv-motors-saudi-arabia">bearing currents in VFD-driven motors</a>.</p></li><li><p>Lubrication problems in hot conditions, see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/electric-motor-bearing-grease-saudi-arabia">greasing motor bearings</a>.</p></li><li><p>Thermal bow and rotor unbalance after long standstill or high-temperature running.</p></li><li><p>Resonance of motor frames on flexible steel structures, common on skids and elevated platforms.</p></li></ul><h2>From diagnosis to repair</h2><p>When the spectrum points to the motor, the next steps are inspection and, if needed, workshop repair: bearing replacement, rotor balancing, air gap correction, rotor bar repair or rewind, as covered in <a href="https://www.btc-ksa.com/Knowledge-Hub/post/hv-motor-rewind-or-replace-saudi-arabia">rewind or replace decisions</a>.</p><h2>WEG from BTGC</h2><p>BTGC is the <a href="https://www.btc-ksa.com/weg">WEG partner in Saudi Arabia</a> for medium and high voltage motors and MV drives. The <a href="https://www.btc-ksa.com/btgc-jubail-service-center">BTGC service center in Jubail</a>, a WEG approved service center, carries out vibration diagnosis, dynamic balancing, bearing and rotor repairs, rewinds and testing for motors of all makes. See also the <a href="https://www.btc-ksa.com/rotating-equipment">rotating equipment</a> page.</p><h2>Questions buyers ask</h2><p><strong>What vibration level is acceptable for a large motor?</strong> It depends on machine size and support; ISO 20816 zones give the limits. Compare with the machine's own baseline as well.</p><p><strong>Can vibration show electrical faults?</strong> Yes. Twice line frequency vibration and pole-pass sidebands point to air gap and rotor bar problems.</p><p><strong>Can BTGC carry out vibration surveys?</strong> Yes, as part of motor diagnosis and repair support from the Jubail service center.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Mon, 16 Nov 2026 11:09:33 +0300</pubDate></item></channel></rss>