<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/koso/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #KOSO</title><description>BTGC - Knowledge Hub #KOSO</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/koso</link><lastBuildDate>Wed, 18 Nov 2026 11:16:45 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Control Valve Seat Leakage Classes: ANSI/FCI 70-2 Class II to VI]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-seat-leakage-classes-fci-70-2-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/koso-severe-service-control-butterfly-valves.webp"/>What control valve leakage classes II to VI mean, how they are tested, and when to ask for Class V or VI, with tips on trim and actuator thrust. KOSO, BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_3ma_6mhARJSQ7RXiB138dw" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_HGLfFUToTaawrrTq-Cji-w" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_yFPFI-XTSZ-9ghL0_61h-Q" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_GbxqoYEJXgyST3TNOnbucQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> control valves are built to regulate flow, not always to shut off tight, so their seat leakage is graded in classes defined by ANSI/FCI 70-2 (and IEC 60534-4). Class IV is common for metal seats, Class V for tight metal seats and Class VI for soft seats. Asking for a tighter class than needed adds cost and actuator size, while asking for too little can waste energy or erode trims. BTGC supplies KOSO control valves and tests valves at its Jubail service center.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/koso-severe-service-control-butterfly-valves.webp" alt="KOSO severe service control valves" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Process and power plants in the Kingdom specify control valve leakage on every data sheet, often without knowing what the class means in practice.</p><h2>The classes in brief</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Class</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Allowed leakage (summary)</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Typical seat</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">II</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">0.5% of rated capacity</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Metal, double-seated valves</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">III</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">0.1% of rated capacity</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Metal, balanced trims</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">IV</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">0.01% of rated capacity</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Metal seats, common default</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">V</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Very small water leakage per inch of port diameter per psi</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Tight metal seats, high thrust</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">VI</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Bubbles per minute of air, by port size</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Soft seats</td></tr></tbody></table><h2>Choosing the class</h2><ul><li><p>Use Class IV where the valve throttles and a separate block valve isolates.</p></li><li><p>Ask for Class V where leakage wastes high-pressure fluid, erodes the seat or affects safety, such as boiler feedwater and high-pressure drop duties.</p></li><li><p>Use Class VI soft seats only within their temperature and media limits.</p></li><li><p>Remember that tighter classes need more actuator thrust to seat the plug.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/valve-test-bench-btgc-service-center-jubail.webp" alt="Valve test bench at the BTGC Jubail service center" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Testing and service</h2><ul><li><p>Seat leakage is tested at the factory and again after repairs, using the method in the standard.</p></li><li><p>Damaged trims leak more over time; plan overhauls before leakage harms the process; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-overhaul-rebuild-saudi-arabia">control valve overhaul</a>.</p></li><li><p>For isolation valves, different standards apply; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/valve-seat-leakage-classes-api-598-iso-5208-saudi-arabia">API 598 and ISO 5208</a>.</p></li><li><p>Review sizing when duty changes; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-sizing-cv-rangeability-saudi-arabia">control valve sizing</a>.</p></li></ul><h2>KOSO from BTGC</h2><p>Nihon KOSO makes control valves and actuators known for severe service trims. BTGC supplies <a href="https://www.btc-ksa.com/koso-saudi-arabia">KOSO in Saudi Arabia</a> with sizing support and spares, and tests valves at the <a href="https://www.btc-ksa.com/btgc-jubail-service-center">Jubail service center</a>.</p><h2>Questions buyers ask</h2><p><strong>Is Class VI always better?</strong> No; soft seats have temperature and erosion limits, and metal seats with Class V may suit hard duties better.</p><p><strong>Can a valve meet a tighter class after repair?</strong> Sometimes, with new trim and lapping; the actuator must still give enough thrust.</p><p><strong>Can BTGC test leakage on site valves?</strong> Valves can be tested at the BTGC Jubail service center.</p><h2>Contact the BTGC valve team</h2><p>Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 14:32:05 +0300</pubDate></item><item><title><![CDATA[Pump Minimum Flow and Recirculation Control Valves]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/pump-minimum-flow-recirculation-valves-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/koso-severe-service-control-butterfly-valves.webp"/>Why boiler feed and pipeline pumps need minimum flow protection, how recirculation valves handle the full pump pressure drop, and how to keep them tight. KOSO.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_lAYLlYmtR9SiVPzbRomndg" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_cpLO9348QdiJAx6DTBZEcg" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_t4R9S39yRTie9wouyL5y5g" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_2dxByh6W5OicuJEmbhUcUQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> centrifugal pumps must never run below a minimum flow, or the liquid inside overheats and internal recirculation damages impellers and bearings. Boiler feed, pipeline and other high-energy pumps therefore have a recirculation line back to the suction tank. The valve in that line drops the full pump pressure, often well over 100 bar, so it faces some of the worst cavitation and erosion in the plant. Multi-stage trim and tight shutoff keep it working and stop wasted energy. BTGC supplies KOSO severe service control valves, including pump recirculation valves.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/koso-severe-service-control-butterfly-valves.webp" alt="KOSO severe service control valves" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Power, desalination and oil and gas plants in the Kingdom run large high-pressure pumps that start, stop and turn down often. Leaking or eroded recirculation valves are a common hidden energy loss.</p><h2>Minimum flow protection options</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Option</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Notes</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Continuous bypass orifice</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Simple but wastes energy all the time</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Modulating recirculation control valve</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Opens only when flow falls; needs flow measurement and control</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Automatic recirculation valve</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Self-acting check and bypass in one body</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">On-off recirculation valve</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Opens at low flow, closes when flow recovers</td></tr></tbody></table><h2>Why recirculation valves wear</h2><ul><li><p>The full differential pressure is taken across one valve.</p></li><li><p>Hot water close to saturation flashes and cavitates.</p></li><li><p>Seat leakage when closed causes wire drawing and steady energy loss.</p></li><li><p>Frequent opening at low lift erodes trim.</p></li><li><p>Poorly designed downstream piping adds vibration.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/main-steam-line-gate-valves-power-plant-saudi-arabia.webp" alt="Power plant piping" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Good practice</h2><ul><li><p>Specify multi-stage pressure-reducing trim designed for cavitating service; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-cavitation-noise-high-pressure-drop-saudi-arabia">cavitation and noise</a>.</p></li><li><p>Require tight shutoff and check for seat leakage with temperature on the outlet line.</p></li><li><p>Size for the real minimum flow given by the pump maker.</p></li><li><p>Use back-pressure devices downstream where recommended.</p></li><li><p>Plan trim inspection at each major outage; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-overhaul-rebuild-saudi-arabia">control valve overhaul</a>.</p></li></ul><h2>KOSO from BTGC</h2><p>Nihon KOSO makes severe service control valves, actuators and positioners for power, oil and gas and process plants. BTGC is the <a href="https://www.btc-ksa.com/koso-saudi-arabia">KOSO partner in Saudi Arabia</a>, with valve testing and repair at the Jubail service center. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/boiler-feedwater-spray-water-control-valves-saudi-arabia">feedwater and spray water valves</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/turbine-bypass-valves-hp-lp-saudi-arabia">turbine bypass valves</a> and the <a href="https://www.btc-ksa.com/power-utilities">power and utilities sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Why does a pump need minimum flow?</strong> Below it, the liquid overheats and internal recirculation damages the pump.</p><p><strong>How can I tell if a recirculation valve leaks?</strong> A warm outlet line when the valve should be closed is a common sign.</p><p><strong>Can BTGC repair recirculation valves?</strong> Yes, at the Jubail service center, with KOSO trim parts.</p><h2>Contact the BTGC valve team</h2><p>Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 08:54:55 +0300</pubDate></item><item><title><![CDATA[Steam Turbine Bypass Valves: HP and LP Bypass in Combined Cycle Plants]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/turbine-bypass-valves-hp-lp-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/koso-severe-service-control-butterfly-valves.webp"/>How HP and LP turbine bypass valves work in combined cycle and cogeneration plants, why they fail, and how to keep them tight and fast. KOSO valves from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_GECQm3z7QP2yZmyA9ZGw8w" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_54JD9UcSQ2WioWd7ZSZF1A" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_hiksPTNhR-KPga8NHF4psA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_4NWQS6D09GKwvxXETO5nMA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> turbine bypass valves let a combined cycle or cogeneration plant send steam around the steam turbine during start-up, shutdown, load rejection or a turbine trip. The HP bypass drops main steam to cold reheat conditions and the LP bypass dumps reheat steam to the condenser, both with water injection to cool the steam. They must open in seconds, control smoothly and shut tight, while facing severe pressure drops, thermal shock and noise. BTGC supplies KOSO severe service control valves, including bypass valves.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/koso-severe-service-control-butterfly-valves.webp" alt="KOSO severe service control valves" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Combined cycle and cogeneration plants in the Kingdom often cycle daily or run at changing loads in summer and winter. Bypass systems are used far more than designers expected, and leaking or slow bypass valves cost fuel and availability.</p><h2>HP and LP bypass at a glance</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Item</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">HP bypass</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">LP bypass</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Steam path</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Main steam to cold reheat</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Hot reheat to condenser</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Cooling water</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Feedwater spray</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Condensate spray</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Main duties</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Start-up, trip, pressure control</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Start-up, trip, condenser protection</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Key risks</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Thermal shock, seat erosion</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Noise, vibration, condenser overload</td></tr></tbody></table><h2>Why bypass valves fail</h2><ul><li><p>Very high pressure drops erode trim and seats, especially when valves throttle near closed.</p></li><li><p>Fast heating during trips causes thermal shock and cracking.</p></li><li><p>Spray water valves suffer cavitation; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/boiler-feedwater-spray-water-control-valves-saudi-arabia">spray water control valves</a>.</p></li><li><p>Seat leakage when closed wastes steam and heat rate.</p></li><li><p>Actuator and positioner problems slow the response during a trip.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/main-steam-line-gate-valves-power-plant-saudi-arabia.webp" alt="Main steam piping in a power plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Keeping bypass systems reliable</h2><ul><li><p>Specify multi-stage pressure-reducing trim and tight shutoff for the real operating range.</p></li><li><p>Check stroke time and fail action at every outage.</p></li><li><p>Monitor downstream temperature to detect seat leakage early.</p></li><li><p>Inspect desuperheater nozzles and spray valves for wear and blockage.</p></li><li><p>Plan trim and seat spares before major outages; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-overhaul-rebuild-saudi-arabia">control valve overhaul</a>.</p></li></ul><h2>KOSO from BTGC</h2><p>Nihon KOSO makes severe service control valves, actuators and positioners for power, oil and gas and process plants. BTGC is the <a href="https://www.btc-ksa.com/koso-saudi-arabia">KOSO partner in Saudi Arabia</a>, with valve testing and repair at the Jubail service center. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/steam-pressure-reducing-valves-saudi-arabia">steam pressure reducing valves</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-cavitation-noise-high-pressure-drop-saudi-arabia">cavitation and noise</a> and the <a href="https://www.btc-ksa.com/power-utilities">power and utilities sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Why does a combined cycle plant need bypass valves?</strong> To run the gas turbine and HRSG while the steam turbine is starting, tripped or shut down.</p><p><strong>How fast must bypass valves open?</strong> Typically within a few seconds after a turbine trip, as set by the plant design.</p><p><strong>Can BTGC repair bypass valves?</strong> Yes, testing and repair at the Jubail service center, with KOSO parts.</p><h2>Contact the BTGC valve team</h2><p>Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 07:26:01 +0300</pubDate></item><item><title><![CDATA[Boiler Feedwater and Spray Water Control Valves in Power and Desalination Plants]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/boiler-feedwater-spray-water-control-valves-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/koso-severe-service-control-butterfly-valves.webp"/>Why feedwater, recirculation and desuperheater spray valves are severe service, how to size and trim them, and keep them tight. KOSO control valves, BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_Z3Y-AqbcREmTVVbvT2CqSw" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_Jtd7IPMrTIKcjyDGm5cgsQ" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_JItUtq14ScmM7sVS4w1M_Q" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_DhGELiHCjtNtrHsuM3nH_Q" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> in steam power, cogeneration and thermal desalination plants, a few control valves decide how well the boiler and steam system behave: feedwater regulating valves, start-up and low-load feedwater valves, pump recirculation valves and desuperheater spray water valves. They take high pressure drops, see temperature swings and must control smoothly from start-up to full load. Wrong sizing or trims lead to cavitation, erosion, leakage and poor drum or temperature control. BTGC supplies KOSO severe service control valves.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/koso-severe-service-control-butterfly-valves.webp" alt="KOSO severe service control valves" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Power and water plants in the Kingdom cycle more often as demand changes through the day and season, which puts extra strain on feedwater and spray valves that were designed for steady base load.</p><h2>Key valves and their challenges</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Valve</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Main challenge</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Main feedwater control</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Accurate level control across a wide load range</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Start-up and low-load feedwater</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Very high pressure drop at low flow, cavitation risk</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Boiler feed pump recirculation</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Full pump pressure dropped to deaerator pressure; severe cavitation duty</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Desuperheater spray water</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">High pressure drop, tight shutoff to avoid spray leakage into hot steam lines</td></tr></tbody></table><h2>Design solutions</h2><ul><li><p>Multi-stage anti-cavitation trims for recirculation and low-load valves; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-cavitation-noise-high-pressure-drop-saudi-arabia">cavitation and noise</a>.</p></li><li><p>Split ranging between a small start-up valve and a large main valve to cover the full load range.</p></li><li><p>Hardened trims and tight shutoff classes to stop leakage that erodes seats and damages steam lines.</p></li><li><p>Positioners with diagnostics to track friction and seat condition.</p></li><li><p>Check every operating case, including start-up, minimum load and pump trips.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/main-steam-line-gate-valves-power-plant-saudi-arabia.webp" alt="Power plant steam line valves" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Maintenance tips</h2><ul><li><p>Watch for leakage on spray valves: water dripping into hot steam lines causes thermal fatigue cracking.</p></li><li><p>Inspect recirculation valve trims at every major outage.</p></li><li><p>Trend valve position against load to detect trim wear.</p></li><li><p>Check positioner calibration and actuator air supply.</p></li><li><p>Keep spare trims for the most severe valves.</p></li></ul><h2>KOSO from BTGC</h2><p>Nihon KOSO makes severe service control valves, actuators and positioners for power, oil and gas and process plants. BTGC is the <a href="https://www.btc-ksa.com/koso-saudi-arabia">KOSO partner in Saudi Arabia</a>, with valve testing and repair at the Jubail service center. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/feedwater-check-valves-power-plants-saudi-arabia">feedwater check valves</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/compressor-anti-surge-valves-saudi-arabia">anti-surge valves</a> and the <a href="https://www.btc-ksa.com/power-utilities">power and utilities sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Why do recirculation valves fail so quickly?</strong> They drop the full pump pressure in one valve; without a multi-stage trim, cavitation erodes them fast.</p><p><strong>Why does spray valve leakage matter?</strong> Water leaking into hot steam lines causes thermal shock and cracking.</p><p><strong>Can BTGC upgrade existing feedwater valves?</strong> Often yes, with new trims or replacement valves sized for the real operating range.</p><h2>Contact the BTGC valve team</h2><p>Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 15:09:05 +0300</pubDate></item><item><title><![CDATA[Compressor Anti-Surge Valves in Gas Plants: Speed, Capacity and Noise]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/compressor-anti-surge-valves-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/koso-severe-service-control-butterfly-valves.webp"/>What an anti-surge valve must do to protect a centrifugal compressor, how to size it, make it fast and keep noise down, and how to test it. KOSO from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_CqMEPtZYSc6WUSKSyRk9SA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_Vm5BuNKpRU6D-regqBPIFw" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_R_W4ptPhR5G4edveIs8tWg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_GbWp2aAUipPM9rhem8PjPQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> centrifugal compressors surge when flow falls too low for the pressure ratio: flow reverses through the machine, shaking the rotor, bearings and seals. The anti-surge control valve recycles gas from discharge back to suction to keep the compressor away from surge. It must open very fast, pass a large flow at high pressure drop without excessive noise, and position accurately so normal recycle does not waste energy. Choosing and testing it correctly is central to compressor protection. BTGC supplies KOSO severe service and anti-surge control valves.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/koso-severe-service-control-butterfly-valves.webp" alt="KOSO severe service control valves" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Gas plants, gas-oil separation plants, refineries and petrochemical complexes in the Kingdom run many large centrifugal compressors for gas gathering, export, refrigeration and recycle gas. A single surge event can damage seals and bearings; repeated surge can destroy a compressor.</p><h2>What the anti-surge valve must do</h2><ul><li><p>Open fully within a very short time, often one to two seconds, when the controller detects approach to surge.</p></li><li><p>Pass the full recycle flow needed at the worst case, typically at start-up or emergency shutdown.</p></li><li><p>Throttle smoothly and accurately during normal recycle control.</p></li><li><p>Handle a high pressure drop with acceptable noise and vibration.</p></li><li><p>Fail open on loss of air or signal.</p></li></ul><h2>Design features</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Feature</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Purpose</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Low-noise, multi-stage trim</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Keeps noise and pipe vibration within limits at high pressure drop; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-cavitation-noise-high-pressure-drop-saudi-arabia">noise in control valves</a></td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">High-capacity body</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Large Cv for full recycle flow</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Fast actuator with boosters and quick exhaust valves</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Achieves short opening times on large actuators</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Accurate digital positioner</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Fine control during normal operation and diagnostics</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Spring-return fail-open actuator</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Opens on loss of supply for compressor safety</td></tr></tbody></table><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/pipeline-gosp-oil-gas-saudi-arabia.webp" alt="Gas gathering and compression facility" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Sizing and testing</h2><ul><li><p>Size from compressor performance maps, using all operating cases, start-up and emergency shutdown, not only the design point.</p></li><li><p>Check the full recycle loop: cooler, piping volume and check valve affect how quickly surge can be prevented.</p></li><li><p>Measure stroke times in both directions at commissioning and after maintenance.</p></li><li><p>Test step response and overshoot with the anti-surge controller.</p></li><li><p>Trend positioner diagnostics to spot friction and air supply problems early.</p></li></ul><h2>KOSO from BTGC</h2><p>Nihon KOSO makes severe service control valves, anti-surge valves, high-performance butterfly valves, actuators and positioners. BTGC is the <a href="https://www.btc-ksa.com/koso-saudi-arabia">KOSO partner in Saudi Arabia</a>, with valve testing and repair at the Jubail service center. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/turbo-compressors-plant-air-air-separation-saudi-arabia">turbo compressors</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-sizing-cv-rangeability-saudi-arabia">control valve sizing</a> and the <a href="https://www.btc-ksa.com/oil-gas">oil and gas sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Can a standard globe valve be used for anti-surge?</strong> Only if it meets the speed, capacity and noise requirements; many standard valves do not.</p><p><strong>Why does the anti-surge valve need to be so fast?</strong> Surge can develop within a fraction of a second after a trip; the valve must open before flow collapses.</p><p><strong>Does BTGC test anti-surge valves?</strong> Yes, including stroke time and response tests at the Jubail service center.</p><h2>Contact the BTGC valve team</h2><p>Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 12:34:05 +0300</pubDate></item><item><title><![CDATA[Cavitation and Noise in Control Valves: Fixing High Pressure Drop Service]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-cavitation-noise-high-pressure-drop-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/koso-severe-service-control-butterfly-valves.webp"/>Why high pressure drop control valves cavitate, flash and get noisy, how multi-stage trims fix it, and what to check in service. KOSO severe service valves.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_hHXSFe-7QR-f2ywZRPVe-Q" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_A-jrhIXHTfWUWMkchF7PpA" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_wuwA0q4gRiqmxeh5iIxm5g" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_NyoDPKC5wz64Hunkv5xJFA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> when a control valve takes a large pressure drop, the liquid can briefly fall below its vapour pressure inside the trim. The vapour bubbles then collapse downstream, eating away plugs, seats and bodies; this is cavitation. If the outlet pressure stays below vapour pressure the fluid flashes instead. In gas service, high pressure drop makes noise and vibration. Standard single-stage trims cannot cope, but multi-stage, velocity-controlled trims split the drop into steps and keep velocities low. BTGC supplies KOSO severe service control valves.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/koso-severe-service-control-butterfly-valves.webp" alt="KOSO severe service control valves and butterfly valves" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Boiler feedwater recirculation, spray water, pump minimum flow, separator level control, high pressure letdown and compressor anti-surge valves are all classic severe service duties in Saudi refineries, gas plants and power stations. These valves often fail in months rather than years if the trim is not designed for the pressure drop.</p><h2>What happens inside the valve</h2><ul><li><p>Flow accelerates through the narrowest point of the trim, the vena contracta, and pressure falls there before partly recovering downstream.</p></li><li><p>If the pressure at the vena contracta drops below the liquid vapour pressure, vapour bubbles form; when pressure recovers they implode against metal surfaces. This is cavitation.</p></li><li><p>If the downstream pressure itself is below vapour pressure, the liquid flashes to vapour and leaves as a high-velocity two-phase flow that erodes the body and piping.</p></li><li><p>At a certain pressure drop the flow chokes: increasing the drop no longer increases flow. IEC 60534-2-1 uses the liquid pressure recovery factor FL to predict this.</p></li><li><p>In gas and steam service, a high pressure ratio creates aerodynamic noise and pipe vibration. Many plants limit noise to about 85 dBA at 1 m, predicted with IEC 60534-8-3.</p></li></ul><h2>How severe service trims solve it</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Approach</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">How it helps</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Multi-stage pressure reduction</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Takes the total drop in several smaller steps, so the pressure never falls below vapour pressure at any stage</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Velocity control</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Limits trim outlet velocity and kinetic energy; KOSO uses multi-stage Vector Velocity Control (VVC) trims for this</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Hardened materials</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Stellite, hardened stainless or other hard-faced trims resist the damage that remains</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Angle bodies and outlet design</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Direct flashing flow away from the body walls into a larger outlet</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Low-noise trims and diffusers</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Split gas flow into many small jets to shift noise to frequencies the pipe radiates less</td></tr></tbody></table><p>Many severe service specifications limit trim exit kinetic energy, often to around 480 kPa (70 psi) for continuous duty, and use cavitation indexes to decide when an anti-cavitation trim is needed. The valve maker should check every operating case, not only the design point: start-up and low-load conditions are often the worst.</p><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/gas-cracker-plant-saudi-arabia.webp" alt="Gas cracker and compressor plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Signs of trouble in service</h2><ul><li><p>A gravel-like noise in liquid service or a loud whistle or roar in gas service.</p></li><li><p>Vibration of the actuator, positioner and nearby piping; loose fittings and tubing failures.</p></li><li><p>Rising seat leakage and loss of control at low openings.</p></li><li><p>Pitting or wire-drawing on plugs and seats at overhaul; erosion of the body downstream of the seat.</p></li><li><p>Positioner diagnostics that show increasing friction or travel deviation, as described in <a href="https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-positioner-diagnostics-saudi-arabia">control valve positioner diagnostics</a>.</p></li></ul><h2>What to send for a severe service selection</h2><ul><li><p>All operating cases: minimum, normal and maximum flow with inlet and outlet pressures and temperatures.</p></li><li><p>Fluid properties, including vapour pressure and critical pressure for liquids.</p></li><li><p>Line size and schedule, allowable noise and required shutoff class.</p></li><li><p>Existing valve data and failure history if it is a replacement.</p></li></ul><h2>KOSO from BTGC</h2><p>Nihon KOSO supplies severe service control valves, high-performance butterfly valves, actuators, positioners and choke valves. BTGC is the <a href="https://www.btc-ksa.com/koso-saudi-arabia">KOSO partner in Saudi Arabia</a>, with valve testing and repair at the BTGC service center in Jubail. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-sizing-cv-rangeability-saudi-arabia">control valve sizing</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/control-valve-overhaul-rebuild-saudi-arabia">control valve overhaul</a> and the <a href="https://www.btc-ksa.com/flow-control-valves-solutions">flow control and valves</a> page.</p><h2>Questions buyers ask</h2><p><strong>Can a standard globe valve be upgraded with an anti-cavitation trim?</strong> Sometimes, if the body can accept a multi-stage trim with enough capacity; otherwise a new valve is needed. BTGC can check the existing valve data.</p><p><strong>Why does damage appear downstream of the valve?</strong> Bubbles collapse where pressure recovers, which can be in the outlet or the pipe just after the valve.</p><p><strong>Does a larger valve reduce cavitation?</strong> No. Cavitation depends on the pressure drop and trim design, not the body size.</p><h2>Contact the BTGC valve team</h2><p>Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 10:19:44 +0300</pubDate></item></channel></rss>