<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/low-smoke-cables/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #low smoke cables</title><description>BTGC - Knowledge Hub #low smoke cables</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/low-smoke-cables</link><lastBuildDate>Wed, 18 Nov 2026 04:47:02 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Fire-Resistant and Low-Smoke (LSZH) Cables Explained]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/fire-resistant-low-smoke-lszh-cables-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/bahra-electric-power-cables.webp"/>The difference between flame-retardant, low-smoke halogen-free and fire-resistant cables, the tests behind them and where projects use each. Bahra Electric.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_AbYtaQjHQB678EJNIVsVzw" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_zKuGhZFRRk6aGae8krQEaQ" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_fmey1SXcTgW1g7iBFniv7w" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_hTOuSrpOKDa9PrAKcpviAA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> three different properties are often confused. Flame-retardant cables limit the spread of fire along a cable run. Low-smoke zero-halogen (LSZH) cables give off little smoke and no corrosive halogen gas when they burn, which protects people and electronics. Fire-resistant cables keep working for a stated time in a fire, so alarms, emergency lighting, fire pumps and smoke fans stay powered. Projects often need all three. BTGC supplies Bahra Electric cables made in Saudi Arabia.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/bahra-electric-power-cables.webp" alt="Bahra Electric power cables" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Hospitals, metro stations, tunnels, high-rise buildings, control rooms and process facilities all have rules on how cables behave in a fire.</p><h2>Three properties, three purposes</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Property</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">What it means</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Typical test standards</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Flame-retardant</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Fire does not spread far along single or bunched cables</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">IEC 60332-1 and IEC 60332-3</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Low smoke, zero halogen</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Little smoke and no halogen acid gases</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">IEC 61034 and IEC 60754</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Fire-resistant (circuit integrity)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Keeps power or signals running in a fire for a set time</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">IEC 60331, BS 6387 or BS 8491, per the specification</td></tr></tbody></table><h2>Where each is used</h2><ul><li><p>LSZH: enclosed public spaces, tunnels, data centres and control rooms, where smoke and corrosive gas are the main danger.</p></li><li><p>Fire-resistant: fire alarm, emergency lighting, fire pump, smoke extraction, emergency shutdown and other critical circuits; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/fire-pumps-nfpa-20-industrial-plants-saudi-arabia">fire pumps</a>.</p></li><li><p>Flame-retardant PVC: general plant power where halogen-free cable is not required and cost matters.</p></li><li><p>Process plants: the owner's specification sets the type per area, so follow the project cable schedule.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/hd-hyundai-electric-transformer-gis.webp" alt="Indoor substation with switchgear and transformer" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Specifying and installing</h2><ul><li><p>State the property and the test standard, not just fire cable.</p></li><li><p>Fire resistance applies to the whole circuit, so use supports, glands and joints that keep it working in a fire.</p></li><li><p>Check current ratings, since fire barriers and grouping change derating; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/cable-derating-hot-climate-saudi-arabia">cable derating in hot climates</a>.</p></li><li><p>Keep fire-resistant and normal circuits separated where the design requires it.</p></li><li><p>For buildings, check the Saudi Building Code and the approving authority.</p></li></ul><h2>Bahra Electric from BTGC</h2><p>Bahra Electric is a Saudi manufacturer of power, control and instrumentation cables and busways. BTGC supplies <a href="https://www.btc-ksa.com/Knowledge-Hub/post/bahra-electric-saudi-arabia">Bahra Electric cables in Saudi Arabia</a> for plants and projects; ask BTGC for the fire-performance constructions available. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/control-instrumentation-cables-saudi-arabia">control and instrumentation cables</a>, the <a href="https://www.btc-ksa.com/electrical-power-systems-saudi-arabia">electrical and power systems</a> page and <a href="https://www.btc-ksa.com/mega-projects-epc">mega-projects and EPC</a>.</p><h2>Questions buyers ask</h2><p><strong>Is an LSZH cable automatically fire-resistant?</strong> No. LSZH describes smoke and gas; fire resistance is a separate circuit-integrity property.</p><p><strong>Do fire-resistant cables cost more?</strong> Yes, they have extra insulation layers, so use them on the circuits that need them.</p><p><strong>Are locally made cables accepted on Saudi projects?</strong> Local content is encouraged on many projects; approval depends on the owner's vendor list.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 13:02:20 +0300</pubDate></item></channel></rss>