<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/motor-coolers/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #motor coolers</title><description>BTGC - Knowledge Hub #motor coolers</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/motor-coolers</link><lastBuildDate>Wed, 18 Nov 2026 07:14:51 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Transformer Radiators and Motor Air Coolers: Cleaning, Leaks and Replacement]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/transformer-radiators-motor-air-coolers-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/weg-water-cooled-electric-motor-saudi-arabia.webp"/>How fouled or leaking transformer radiators and motor air coolers raise temperatures, how to clean and test them, and when to replace them. Rex from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_ofLlchW4Qg-DyYdib_IIaw" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_JsNI8KpPR2qd13P-vYyvxg" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_hzBwt-D_S22pM4PgSz-atA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_5LNQT_NuUBDOPZzOr_mbFA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> large transformers and motors depend on their coolers to stay within temperature limits. Transformer radiators cool the oil, and motors use air-to-air (CACA) or air-to-water (CACW) coolers mounted on the machine. Dust, sand and salt reduce heat transfer, and leaking tubes in water-cooled motor coolers can put water into the windings. Regular cleaning, leak testing and timely replacement keep machines from overheating and ageing early. BTGC supplies Rex finned tube coolers and radiators.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/weg-water-cooled-electric-motor-saudi-arabia.webp" alt="Water-cooled electric motor with top-mounted cooler" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Sand and dust storms, coastal humidity and high summer temperatures in the Kingdom put coolers under constant stress. A cooler that has lost a fraction of its capacity may go unnoticed until the hottest weeks of the year, when the machine trips or runs over temperature.</p><h2>Where coolers are used</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Equipment</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Cooler type</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Oil-filled transformers</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Radiators with natural (ONAN) or fan (ONAF) air flow</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Large motors and generators, air-cooled</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Air-to-air tube coolers (CACA) on top of the machine</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Large motors and generators, water-cooled</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Air-to-water coolers (CACW) with leak detection</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Gear units and lube oil systems</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Finned tube or shell and tube oil coolers</td></tr></tbody></table><h2>Signs a cooler needs attention</h2><ul><li><p>Winding, oil or bearing temperatures rising year on year at the same load.</p></li><li><p>Visible dust or sand packed between fins.</p></li><li><p>Corrosion of fins and tube sheets, especially near the coast.</p></li><li><p>Leak detector alarms or damp marks on water-cooled motor coolers.</p></li><li><p>Cooling fans not running or running slowly.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/large-power-transformer-radiators-cooling-fans.webp" alt="Transformer radiators and cooling fans" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Cleaning, testing and replacement</h2><ul><li><p>Clean fins with compressed air or low-pressure water from the clean side, without bending fins.</p></li><li><p>Pressure test water-cooled coolers at overhauls and repair or plug leaking tubes.</p></li><li><p>Check fans, motors and thermostats on transformer cooling systems before summer.</p></li><li><p>Replace coolers that have lost too much capacity or have repeated leaks; choose tube and fin materials suited to the water and air quality.</p></li><li><p>Make sure replacements match thermal rating and mounting dimensions.</p></li></ul><h2>Rex from BTGC</h2><p>Rex Heat Exchanger of India makes finned tube heat exchangers, radiators and coolers for transformers, motors, generators and compressors. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/rex-heat-exchanger-saudi-arabia">Rex partner in Saudi Arabia</a>, with full electric motor services at the Jubail service center. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/water-cooled-electric-motors-saudi-arabia">water-cooled electric motors</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/transformer-loading-high-ambient-saudi-arabia">transformer loading in high ambient</a> and <a href="https://www.btc-ksa.com/Knowledge-Hub/post/air-fin-coolers-air-cooled-heat-exchangers-saudi-arabia">air fin coolers</a>.</p><h2>Questions buyers ask</h2><p><strong>How often should transformer radiators be cleaned?</strong> At least before each summer, and more often on dusty or coastal sites.</p><p><strong>Can a leaking CACW cooler be repaired?</strong> Often yes, by plugging or replacing tubes, but repeated leaks usually mean replacement is due.</p><p><strong>Does BTGC supply replacement coolers for other brands?</strong> Yes, Rex can build coolers to match existing dimensions and ratings.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 12:00:57 +0300</pubDate></item></channel></rss>