<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/mv-motors/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #MV motors</title><description>BTGC - Knowledge Hub #MV motors</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/mv-motors</link><lastBuildDate>Wed, 18 Nov 2026 04:15:49 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Vibration Analysis for Large Electric Motors: What the Spectrum Tells You]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/motor-vibration-analysis-spectrum-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/weg-high-voltage-motor-w60.webp"/>How to read vibration spectra on large motors: unbalance, misalignment, looseness, bearing defects and electrical faults at twice line frequency. WEG from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_ZhQJZSK1SEuGIe9o1SDaEQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_cI2tjuXXQzGOTFWI-8VK2g" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_Xw77Qp20Sq2lSQzsr8fmSg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_9d_S7zdmCy6JNHUPxhv1JQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> vibration is the most useful single indicator of a large motor's health. Overall levels compared with ISO 20816 zones show whether a machine is acceptable; the frequency spectrum shows why it vibrates. Mechanical faults such as unbalance, misalignment and looseness appear at running speed and its harmonics, bearing faults at their own defect frequencies, and electrical faults at twice line frequency or as sidebands. BTGC supplies WEG MV and HV motors and diagnoses and repairs motor faults at its WEG approved service center in Jubail.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/weg-high-voltage-motor-w60.webp" alt="WEG high voltage industrial motor" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Saudi plants run large motors on compressors, pumps, fans and mills, and many are monitored by portable routes or online systems. The data is only useful if someone can read it. A vibration spectrum splits the overall level into its frequency components, and each common motor fault leaves a recognisable pattern.</p><h2>Severity: how much is too much</h2><p>ISO 20816, which replaces the earlier ISO 10816 parts, sets vibration evaluation zones for industrial machines by size and support type: zone A for newly commissioned machines, B for unrestricted long-term operation, C for limited operation until there is an opportunity to repair, and D for vibration severe enough to cause damage. Trends matter as much as zones: a steady rise inside zone B is an early warning.</p><h2>Reading the spectrum</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Pattern</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Likely cause</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">High 1x running speed, mainly radial, steady phase</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Unbalance</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">High 1x and 2x, high axial vibration, phase shift across the coupling</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Misalignment</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Many harmonics of running speed, sometimes half-orders</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Mechanical looseness, or a cracked foot or base</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Non-synchronous peaks at bearing defect frequencies, with harmonics and sidebands</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Rolling bearing defects</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Sub-synchronous peak around 0.4 to 0.5x on sleeve bearings</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Oil whirl or bearing instability</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Peak at twice line frequency (120 Hz on the Saudi 60 Hz grid) that disappears the instant power is cut</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Electrical: uneven air gap, stator problems, soft foot distorting the frame</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Pole-pass sidebands around 1x and its harmonics</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Rotor bar or end ring problems</td></tr></tbody></table><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/weg-water-cooled-electric-motor-saudi-arabia.webp" alt="WEG medium voltage motor" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Separating mechanical and electrical causes</h2><p>A simple test is to watch the vibration as the motor is switched off. Electrically caused vibration at twice line frequency disappears the moment power is removed, while mechanical vibration decays with speed. An uncoupled run separates motor problems from the driven machine, and motor current signature analysis adds detail on rotor bar faults.</p><h2>Common motor-specific causes in the Kingdom</h2><ul><li><p>Soft foot and base problems after relocation or poor grouting.</p></li><li><p>Bearing damage from VFD currents, described in <a href="https://www.btc-ksa.com/Knowledge-Hub/post/vfd-bearing-currents-mv-motors-saudi-arabia">bearing currents in VFD-driven motors</a>.</p></li><li><p>Lubrication problems in hot conditions, see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/electric-motor-bearing-grease-saudi-arabia">greasing motor bearings</a>.</p></li><li><p>Thermal bow and rotor unbalance after long standstill or high-temperature running.</p></li><li><p>Resonance of motor frames on flexible steel structures, common on skids and elevated platforms.</p></li></ul><h2>From diagnosis to repair</h2><p>When the spectrum points to the motor, the next steps are inspection and, if needed, workshop repair: bearing replacement, rotor balancing, air gap correction, rotor bar repair or rewind, as covered in <a href="https://www.btc-ksa.com/Knowledge-Hub/post/hv-motor-rewind-or-replace-saudi-arabia">rewind or replace decisions</a>.</p><h2>WEG from BTGC</h2><p>BTGC is the <a href="https://www.btc-ksa.com/weg">WEG partner in Saudi Arabia</a> for medium and high voltage motors and MV drives. The <a href="https://www.btc-ksa.com/btgc-jubail-service-center">BTGC service center in Jubail</a>, a WEG approved service center, carries out vibration diagnosis, dynamic balancing, bearing and rotor repairs, rewinds and testing for motors of all makes. See also the <a href="https://www.btc-ksa.com/rotating-equipment">rotating equipment</a> page.</p><h2>Questions buyers ask</h2><p><strong>What vibration level is acceptable for a large motor?</strong> It depends on machine size and support; ISO 20816 zones give the limits. Compare with the machine's own baseline as well.</p><p><strong>Can vibration show electrical faults?</strong> Yes. Twice line frequency vibration and pole-pass sidebands point to air gap and rotor bar problems.</p><p><strong>Can BTGC carry out vibration surveys?</strong> Yes, as part of motor diagnosis and repair support from the Jubail service center.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Mon, 16 Nov 2026 11:09:33 +0300</pubDate></item><item><title><![CDATA[Storing and Preserving MV Motors Before Commissioning]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/mv-motor-storage-preservation-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/weg-water-cooled-electric-motor-saudi-arabia.webp"/>How to store medium and high voltage motors on Saudi project sites: heaters, insulation resistance checks, shaft rotation and bearing care. WEG from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_HUMyqrVqQUKDlk1Ya5RPtg" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_zLcWg-G-Rrubnn0XXIMgRg" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_HLEIdt_tQkG1uGk6HKdn6Q" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_2sUWHjyPMYr0OQBDZzy8hw" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> large motors often wait months, sometimes years, between delivery and commissioning on Saudi projects. In that time dust, humidity swings, condensation and vibration from nearby work can damage windings and bearings before the motor ever runs. A preservation routine (dry, covered storage, energised space heaters, periodic insulation resistance tests, regular shaft rotation and correct bearing care) protects the motor and the warranty and avoids failures at start-up. BTGC supplies WEG MV and HV motors and supports preservation, inspection and pre-commissioning checks.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/weg-water-cooled-electric-motor-saudi-arabia.webp" alt="WEG medium voltage motor" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>On large projects, motors arrive early with the driven equipment packages and then sit on laydown yards, in partly built substations or on installed skids while construction continues. Coastal sites see high humidity at night and temperatures above 45 &deg;C by day; inland sites see dust storms. Both are hard on insulation and bearings that are not running.</p><h2>What goes wrong in storage</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Risk</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Cause</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Result</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Low insulation resistance</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Moisture absorbed by windings during humid nights, condensation</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Failed IR or PI test at commissioning, or a fault at first energisation</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">False brinelling</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Vibration from nearby equipment while the shaft is stationary</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Marked bearing races and noisy bearings from day one</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Bearing corrosion</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Condensation in bearing housings, degraded grease or oil</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Pitting and early bearing failure</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Dust and sand ingress</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Open terminal boxes, missing covers, outdoor storage</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Contaminated windings, blocked cooling passages</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Sleeve bearing damage</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Oil drained for shipping not refilled, or the shaft turned dry</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Wiped bearing surfaces</td></tr></tbody></table><h2>A practical preservation routine</h2><ul><li><p><strong>Store indoors or under cover</strong>, on a level base, away from vibration sources, with terminal boxes and openings sealed.</p></li><li><p><strong>Energise the space heaters</strong> continuously in storage and after installation until the motor runs, to keep the windings above the dew point.</p></li><li><p><strong>Measure insulation resistance and polarisation index</strong> on arrival and at regular intervals, typically monthly, and record them with the winding temperature.</p></li><li><p><strong>Rotate the shaft</strong> by hand every few weeks to a new position, to redistribute lubricant and change the loaded points in rolling bearings; refit the transport lock before moving the motor.</p></li><li><p><strong>Look after bearings and lubricant</strong>: keep sleeve bearing housings at the storage oil level the maker specifies, and regrease rolling bearings as the storage instructions require.</p></li><li><p><strong>Protect machined surfaces</strong> such as shaft ends and feet with preservative, and inspect it periodically.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/weg-high-voltage-motor-w60.webp" alt="WEG high voltage industrial motor" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Insulation resistance targets</h2><p>IEEE 43 gives the recommended minimum insulation resistance and polarisation index for rotating machines. For form-wound MV windings, the recommended minimum insulation resistance corrected to 40 &deg;C is 100 megohms, and the recommended minimum polarisation index for Class F insulation is 2.0. A falling trend in storage matters more than any single reading: it shows moisture getting in, and the winding should be dried with heaters or a controlled low-voltage current before the motor is energised.</p><h2>Before the first start</h2><ul><li><p>Review the storage records with the commissioning team and the manufacturer.</p></li><li><p>Repeat IR and PI tests, and dry the winding if the results are low.</p></li><li><p>Inspect bearings, renew grease or oil if storage has exceeded the maker's limit, and check end float.</p></li><li><p>Remove the transport lock, check alignment and soft foot, and confirm cooling paths are clear.</p></li><li><p>Run uncoupled first where the procedure allows, with vibration and temperature monitoring.</p></li></ul><h2>WEG from BTGC</h2><p>BTGC is the <a href="https://www.btc-ksa.com/weg">WEG partner in Saudi Arabia</a> for medium and high voltage motors and MV drives. The <a href="https://www.btc-ksa.com/btgc-jubail-service-center">BTGC service center in Jubail</a>, a WEG approved service center, carries out site inspections, winding drying, bearing work and pre-commissioning tests. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/preventing-stator-winding-failure-duraguard-vpi-insulation-saudi-arabia">preventing stator winding failure</a> and <a href="https://www.btc-ksa.com/Knowledge-Hub/post/vfd-bearing-currents-mv-motors-saudi-arabia">bearing currents in VFD-driven motors</a>.</p><h2>Questions buyers ask</h2><p><strong>How long can an MV motor be stored?</strong> With proper preservation, many months to years; beyond the maker's storage limit, bearings and lubricants need inspection or renewal before start-up.</p><p><strong>Should heaters stay on after installation?</strong> Yes, until the motor is in regular service, and during long stops afterwards.</p><p><strong>Can BTGC check motors stored on our site?</strong> Yes. BTGC can inspect, test and report on stored motors and carry out drying or bearing work where needed.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Mon, 16 Nov 2026 10:33:42 +0300</pubDate></item><item><title><![CDATA[Bearing Currents in VFD-Driven Motors: Causes and Cures]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/vfd-bearing-currents-mv-motors-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/weg-high-voltage-motor-w60.webp"/>Why motors on variable frequency drives suffer bearing fluting, and how insulated bearings, shaft grounding and cabling prevent it. WEG MV motors from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_xn73p17mTBSQqsMvkZawEA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_-Zs6XTK8RZS1B3sbQ5Zsjw" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_hge1fO5HSeGOxQ6oWjWC3Q" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_FyDTQb1Tm_3w-5n7upoA2Q" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> variable frequency drives save energy and soften starts, but the fast switching of the inverter puts a common-mode voltage on the motor that can discharge through the bearings. The result is electrical erosion: frosted races, washboard fluting, noisy bearings and early failure, sometimes within months. The cure is a system design that gives the current a better path: insulated bearings, shaft grounding, symmetrical shielded cable and proper bonding. BTGC supplies WEG medium and high voltage motors and drives configured for VFD duty and repairs damaged motors at its WEG approved service center in Jubail.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/weg-high-voltage-motor-w60.webp" alt="WEG industrial electric motor" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>A typical story: a pump or fan motor is converted from direct-on-line starting to a VFD to save energy. A year later the bearings are noisy, vibration analysis shows bearing defect frequencies, and the removed bearing has a grey, frosted race with evenly spaced ridges like a washboard. The grease is dark. The bearing did not fail from load or lubrication; it was machined by millions of tiny electrical discharges.</p><h2>Where the current comes from</h2><p>A PWM inverter switches very fast, and the sum of the three phase voltages at the motor is no longer zero as it is on a sine-wave supply. This common-mode voltage couples through the motor's internal capacitances onto the rotor and shaft. When the voltage across the bearing's oil film exceeds its breakdown level, it discharges through the rolling elements. IEC TS 60034-25 describes the mechanisms and the measures that limit them.</p><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Type of bearing current</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Typical motors</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Mechanism</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Capacitive discharge (EDM)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Small and medium motors</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Shaft voltage builds up and discharges through the oil film in short sparks</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Circulating high-frequency current</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Larger motors, roughly 100 kW and above</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Common-mode current in the stator induces a voltage along the shaft, driving current through one bearing, the frame and the other bearing</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Rotor ground current</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Installations with poor frame earthing or bonding</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Current finds its way to earth through the bearings and the driven machine, often damaging pump or gearbox bearings too</td></tr></tbody></table><h2>Signs of electrical bearing damage</h2><ul><li><p>Frosted or matt grey raceways, often with fluting: evenly spaced ridges across the race.</p></li><li><p>Micro-craters visible under magnification on balls or rollers.</p></li><li><p>Grease darkened by metal particles and burnt oil.</p></li><li><p>Rising high-frequency vibration and noise at bearing defect frequencies.</p></li><li><p>Damage in the driven equipment's bearings as well as the motor's.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/electric-motor-stator-rewind-btgc-jubail-workshop.webp" alt="Large electric motor stator in the BTGC motor workshop in Jubail" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>How to prevent it</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Measure</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">What it does</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Insulated bearing (usually non-drive end) or ceramic rolling elements</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Breaks the circulating current loop through the bearings</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Shaft grounding brush or ring at the drive end</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Gives shaft voltage a low-impedance path to the frame instead of through the bearing</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Symmetrical shielded motor cable with 360-degree gland termination</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Returns common-mode current to the drive along the shield, not through the motor and driven machine</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">High-frequency bonding between motor frame, driven machine and drive</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Keeps frame and driven machine at the same potential</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Insulated coupling</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Stops current passing into the driven machine's bearings</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Common-mode or output filters at the drive</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Reduce the common-mode voltage and the rate of voltage rise at the source</td></tr></tbody></table><p>No single item works on every installation. Large MV motors on drives usually combine an insulated non-drive end bearing with a shaft grounding device and correct cabling, and the winding insulation must also be rated for the voltage stresses of inverter duty, as covered in <a href="https://www.btc-ksa.com/Knowledge-Hub/post/preventing-stator-winding-failure-duraguard-vpi-insulation-saudi-arabia">preventing stator winding failure</a>.</p><h2>When retrofitting a VFD to an existing motor</h2><ul><li><p>Check with the motor maker that the insulation system suits inverter duty.</p></li><li><p>Fit an insulated non-drive end bearing at the next overhaul, and a shaft grounding device at the drive end.</p></li><li><p>Review the cable type and the earthing and bonding scheme, not just the motor.</p></li><li><p>Measure shaft voltage after commissioning and trend bearing vibration in the first months.</p></li></ul><h2>WEG motors and drives from BTGC</h2><p>BTGC is the <a href="https://www.btc-ksa.com/weg">WEG partner in Saudi Arabia</a> for medium and high voltage motors and MV drives, and new WEG motors for VFD duty can be specified with insulated bearings and shaft grounding. The <a href="https://www.btc-ksa.com/btgc-jubail-service-center">BTGC service center in Jubail</a>, a WEG approved service center, inspects and repairs motors with electrical bearing damage and fits insulated bearings during overhaul. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/converting-mv-soft-starters-weg-mvw3000-vfd-saudi-arabia">converting MV soft starters to VFDs</a> and <a href="https://www.btc-ksa.com/Knowledge-Hub/post/hv-motor-rewind-or-replace-saudi-arabia">rewind or replace decisions</a>.</p><h2>Questions buyers ask</h2><p><strong>Do all motors on VFDs need insulated bearings?</strong> Not all. Smaller motors may only need correct cabling and bonding; larger motors on drives usually need an insulated bearing and a shaft grounding device. BTGC reviews the installation.</p><p><strong>Can fluting be repaired?</strong> The damaged bearing must be replaced, and the cause must be fixed, or the new bearing will fail the same way.</p><p><strong>Can shaft voltage be measured on site?</strong> Yes, with an oscilloscope and a shaft voltage probe while the motor runs on the drive; the result shows which measures are needed.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Mon, 16 Nov 2026 09:54:31 +0300</pubDate></item></channel></rss>