<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/panel-air-conditioners/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #panel air conditioners</title><description>BTGC - Knowledge Hub #panel air conditioners</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/panel-air-conditioners</link><lastBuildDate>Wed, 18 Nov 2026 11:17:11 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Enclosure Heat Load: How to Size Panel Cooling]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/enclosure-heat-load-calculation-panel-cooling-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/pfannenberg-enclosure-cooling-units.webp"/>How to calculate heat load in control panels and drive enclosures: internal losses, ambient and solar gain, target temperature and cooling choice. Pfannenberg.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_UqVseG-9RtaM9kgcHyTtlQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_NGwIpuPnQyWXlXTHnC-7fQ" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_K7Hh6kXXR1eVN-6T4t_qjg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_lX8XXZCzW8MlEl2baSHQSQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> sizing enclosure cooling starts with the heat that must be removed: losses from drives, power supplies and other equipment inside, plus heat flowing in through the walls when the outside is hotter than the panel. In Saudi summers, ambient and solar gain can be as large as the internal load. The total, compared with the target internal temperature, decides whether filter fans are enough or an air conditioner or air-to-water exchanger is needed. BTGC supplies Pfannenberg enclosure cooling.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/pfannenberg-enclosure-cooling-units.webp" alt="Pfannenberg enclosure cooling units" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Drive panels, MCCs and control cabinets in the Kingdom often sit in plant rooms or outdoors at 45 °C and above.</p><h2>The parts of the heat load</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Source</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">How to estimate</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Internal losses</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Add up equipment losses from data sheets; drives typically lose a few percent of their power as heat</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Heat through the walls</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Enclosure surface area x heat transfer coefficient x temperature difference</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Solar gain</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Extra load for outdoor panels in sun; shading cuts it a lot</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Margin</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Future equipment and dust on coils and filters</td></tr></tbody></table><h2>Choosing the cooling method</h2><ul><li><p>Filter fans: only when outside air is always cooler than the target inside temperature, and clean enough.</p></li><li><p>Air-to-air heat exchangers: a closed loop, but still need outside air cooler than inside.</p></li><li><p>Enclosure air conditioners: cool below ambient, the usual choice when ambient exceeds the target, as in Saudi summers.</p></li><li><p>Air-to-water heat exchangers: for high loads where chilled or cooling water is available.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/danfoss-vacon-ac-drives-range.webp" alt="AC drives installed in control panels" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>An example in words</h2><ul><li><p>A drive panel with 2 kW of internal losses, a target of 35 °C and an ambient of 50 °C also gains heat through its walls, so the cooler must remove more than 2 kW.</p></li><li><p>Filter fans cannot work here, because the outside air is hotter than the target.</p></li><li><p>An air conditioner sized for the total load at 50 °C ambient is needed, not one sized at a standard rating point.</p></li><li><p>Check capacity at the real ambient, since cooling capacity falls as ambient rises.</p></li></ul><h2>Pfannenberg from BTGC</h2><p>Pfannenberg makes enclosure air conditioners, air-to-water heat exchangers, filter fans and process chillers. BTGC supplies <a href="https://www.btc-ksa.com/Knowledge-Hub/post/pfannenberg-saudi-arabia">Pfannenberg in Saudi Arabia</a> and helps select the right unit. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/enclosure-cooling-electrical-panels-saudi-arabia">cooling electrical panels</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/enclosure-condensation-heaters-hygrostats-saudi-arabia">condensation in enclosures</a> and <a href="https://www.btc-ksa.com/thermal-management-cooling">thermal management and cooling</a>.</p><h2>Questions buyers ask</h2><p><strong>What temperature should a panel be kept at?</strong> Much equipment is rated for about 35 to 40 °C inside the enclosure; check the equipment data.</p><p><strong>Are filter fans ever enough in Saudi Arabia?</strong> Sometimes in air-conditioned rooms; outdoors in summer, usually not.</p><p><strong>Does dust reduce cooling?</strong> Yes, clogged filters and coils cut capacity, so plan regular cleaning.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 13:14:19 +0300</pubDate></item><item><title><![CDATA[Cooling Electrical Panels and Drive Enclosures in Saudi Heat]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/enclosure-cooling-electrical-panels-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/pfannenberg-enclosure-cooling-units.webp"/>How to keep VFDs, PLCs and switchgear panels cool in Saudi heat: fans, heat exchangers or cooling units, heat load sizing and condensation. Pfannenberg.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_Ce7kDqRhTOu8_1mXhuo8pw" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_n1pbgZPTQ2q9cCldlVUObQ" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_RK2HPtD9RcWzqEv-tN_Pyg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_gNP4rZgAnJ_o2YxC-iWqKA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> electronics fail early when they run hot. Drives, PLCs, power supplies and protection relays inside closed panels add their own heat to the hot air around them, and in Saudi summers the outside air is often hotter than the electronics can tolerate. Filter fans and air-to-air heat exchangers only work when the outside air is cooler than the required panel temperature; otherwise a refrigerant cooling unit or an air-to-water heat exchanger is needed. Correct sizing, sealing and condensate handling are the keys. BTGC supplies Pfannenberg enclosure cooling, chillers and signalling products.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/pfannenberg-enclosure-cooling-units.webp" alt="Pfannenberg enclosure cooling units" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Outdoor kiosks, motor control centres, VFD panels in pump stations and control panels on skids are common in Saudi plants. Many electronics are rated for about 40 to 50 degC, while panels in the sun can easily exceed that without active cooling.</p><h2>Choosing the cooling method</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Method</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Works when</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Notes</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Filter fan</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Outside air is well below the required panel temperature</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Cheapest; brings in dust, so filters need cleaning</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Air-to-air heat exchanger</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Outside air is below the panel temperature</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Keeps the panel sealed from dust</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Cooling unit (panel air conditioner)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Outside air is hotter than the required panel temperature</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Usual choice for Saudi summers; needs condensate management</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Air-to-water heat exchanger</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Chilled or cooling water is available</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">High capacity, sealed panel</td></tr></tbody></table><h2>Sizing the heat load</h2><ul><li><p>Add the heat losses of all equipment; drives typically lose a few percent of their rated power as heat.</p></li><li><p>Add heat entering through the panel walls from hot air and direct sun.</p></li><li><p>Choose the maximum allowed inside temperature from the equipment data, often around 35 degC.</p></li><li><p>Size for the hottest expected ambient, not the yearly average.</p></li><li><p>Shade outdoor panels where possible to cut solar gain.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/danfoss-vacon-ac-drives-range.webp" alt="AC drives inside an electrical panel" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Installation and maintenance</h2><ul><li><p>Keep the panel sealed to its IP rating; open cable entries let in hot, dusty air. See <a href="https://www.btc-ksa.com/Knowledge-Hub/post/ip-ratings-plugs-sockets-enclosures-saudi-arabia">IP ratings</a>.</p></li><li><p>Arrange airflow so cold air reaches equipment and does not short-circuit back to the unit.</p></li><li><p>Fit door switches so cooling units stop when the door is open, reducing condensation.</p></li><li><p>Lead condensate safely away from electrical equipment.</p></li><li><p>Clean condenser coils and filters regularly; dust is the main cause of cooling unit trips.</p></li></ul><h2>Pfannenberg from BTGC</h2><p>Pfannenberg of Germany makes filter fans, cooling units, heat exchangers and process chillers for electrical enclosures, and signalling devices. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/pfannenberg-saudi-arabia">Pfannenberg partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/vfd-pumps-fans-energy-savings-harmonics-saudi-arabia">VFDs for pumps and fans</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/substation-ups-batteries-high-temperature-nicd-lead-acid-saudi-arabia">batteries in Saudi heat</a> and the <a href="https://www.btc-ksa.com/electrical-power-systems-saudi-arabia">electrical power systems</a> page.</p><h2>Questions buyers ask</h2><p><strong>Why does my drive panel trip on high temperature only in summer?</strong> The outside air is too hot for fans to cool the panel; a cooling unit is usually needed.</p><p><strong>Can a cooling unit be fitted to an existing panel?</strong> Yes, on the side wall, door or roof, after checking the heat load and panel structure.</p><p><strong>Does BTGC help with heat load calculations?</strong> Yes, from the equipment list, panel size and site conditions.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 11:59:45 +0300</pubDate></item></channel></rss>