<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/power-cables/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #power cables</title><description>BTGC - Knowledge Hub #power cables</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/power-cables</link><lastBuildDate>Wed, 18 Nov 2026 11:16:35 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Cable Current Rating and Derating in Hot Climates]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/cable-derating-hot-climate-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/bahra-electric-power-cables.webp"/>Why cables carry less current in Saudi heat: air and ground temperature, dry soil, grouping and sun, and how to size cables safely. Bahra Electric.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_eAtOj1CXRV25xkgoQ4Q_NQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_Ad6D3IboQ8S99IxVQrjpVg" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_5poUA20qTd22f6eZH6b42g" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_V8W4Bq3kMzHImIuuJMizsQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> a cable rating in a catalogue applies to standard conditions, often 30 degC air or 20 degC ground in IEC tables. In the Kingdom, air temperatures pass 50 degC, desert sand is dry and holds heat, cables run in crowded trays and trenches, and some routes sit in direct sun. Each of these reduces how much current a cable can carry safely. Applying derating factors, or calculating ratings to IEC 60287 for large circuits, avoids overheated insulation and early failures. BTGC supplies Bahra Electric power cables.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/bahra-electric-power-cables.webp" alt="Bahra Electric power cables" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Industrial plants, solar farms, data centres and city networks in the Kingdom install long cable runs in harsh thermal conditions. Undersized cables often work for years, then fail in a hot summer.</p><h2>Factors that reduce cable rating</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Factor</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Why it matters</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">High ambient air temperature</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Less temperature margin to the conductor limit</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Ground temperature and dry soil</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Dry sand has high thermal resistivity and holds heat</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Grouping</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Cables in trays, ducts or trenches heat each other</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Solar radiation</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Exposed cables gain extra heat from the sun</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Burial depth and ducts</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Deeper burial and ducts change heat dissipation</td></tr></tbody></table><h2>Sizing good practice</h2><ul><li><p>Use site-specific ambient and soil data, not catalogue defaults.</p></li><li><p>Apply derating factors from IEC 60364-5-52 for low voltage circuits.</p></li><li><p>Calculate ratings to IEC 60287 for medium voltage and critical feeders; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/medium-voltage-power-cables-selection-saudi-arabia">MV cable selection</a>.</p></li><li><p>Allow for future load growth and harmonics.</p></li><li><p>Consider busways for high current runs; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/busway-busbar-trunking-vs-cables-saudi-arabia">busway vs cables</a>.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/oil-gas-facility-saudi-arabia.webp" alt="Industrial facility cable routes" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Reducing thermal problems on site</h2><ul><li><p>Use thermal backfill around buried cables where soil is poor.</p></li><li><p>Space cables in trays and avoid overfilled trenches.</p></li><li><p>Shade or cover cables exposed to direct sun.</p></li><li><p>Check terminations and joints with thermography.</p></li><li><p>Record loads and temperatures on critical feeders.</p></li></ul><h2>Bahra Electric from BTGC</h2><p>Bahra Electric is a Saudi manufacturer of power, control and instrumentation cables and busways. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/bahra-electric-saudi-arabia">Bahra Electric partner</a> for plants and projects. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/control-instrumentation-cables-saudi-arabia">control and instrumentation cables</a>, the <a href="https://www.btc-ksa.com/electrical-power-systems-saudi-arabia">electrical power systems</a> page and the <a href="https://www.btc-ksa.com/power-utilities">power and utilities sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Why does dry sand reduce cable rating?</strong> Dry sand conducts heat poorly, so buried cables run hotter.</p><p><strong>Which standard covers cable rating calculations?</strong> IEC 60287 is widely used for calculating current ratings.</p><p><strong>Does BTGC supply Saudi-made cables?</strong> Yes, Bahra Electric power and control cables.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 08:08:26 +0300</pubDate></item><item><title><![CDATA[Choosing Medium Voltage Power Cables for Saudi Plants and Projects]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/medium-voltage-power-cables-selection-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/bahra-electric-power-cables.webp"/>How to select XLPE medium voltage cables: conductor, screen, armour and sheath, derating for Saudi soil and heat, and site testing. Bahra Electric from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_mxBeSxnCTDa_Msn3FMk54w" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_gpXW_pOXSLOjKHmZq6hfkQ" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_O6Lf3IzKSy-xx49OryXiQw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_DLayS4M_-_StV7LvSRjLeA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> medium voltage cables carry power from substations to motors, transformers and switchgear across plants, and a wrongly sized or poorly installed cable is a long-term risk. Most MV cables today are XLPE insulated to IEC 60502-2. The key choices are conductor material and size, screen and armour design, sheath material, and derating for the actual soil, depth, grouping and ground temperature, which in Saudi Arabia are often higher than standard assumptions. BTGC supplies Bahra Electric cables made in the Kingdom.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/bahra-electric-power-cables.webp" alt="Bahra Electric power cable cross sections" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Plant expansions, new industrial cities, renewable projects and utility networks in the Kingdom use large quantities of 13.8 kV and 33 kV cable. Cable failures often appear years after installation, at joints and terminations or where the cable has been running hotter than its design.</p><h2>Main construction choices</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Element</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Options and notes</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Conductor</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Copper for compact size and lower losses; aluminium for lower cost and weight on long runs</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Insulation</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">XLPE rated 90 degC continuous, to IEC 60502-2 for 6 to 30 kV</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Screen</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Copper tape or wire screen sized for the earth fault current and duration</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Armour</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Steel wire armour for multicore cables; aluminium wire armour for single-core cables to avoid heating from magnetic losses</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Sheath</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">PVC or PE for general use; low smoke zero halogen where people may be exposed to fire smoke</td></tr></tbody></table><h2>Derating for site conditions</h2><ul><li><p>Ground temperature: deep soil in the Kingdom is often warmer than the 20 degC used in many rating tables.</p></li><li><p>Soil thermal resistivity: dry sand can be much worse than the standard value; thermal backfill helps.</p></li><li><p>Grouping: cables laid close together heat each other; spacing and formation matter.</p></li><li><p>Depth of burial and direct sun on cables in air or trays.</p></li><li><p>Check voltage drop and short-circuit withstand of conductor and screen as well as current rating.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/hd-hyundai-electric-transformer-gis.webp" alt="Substation with transformer and switchgear" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Installation and testing</h2><ul><li><p>Respect minimum bending radius and maximum pulling tension during laying.</p></li><li><p>Use jointing and termination kits matched to the cable and installed by trained jointers.</p></li><li><p>After installation, carry out sheath integrity tests and AC or VLF withstand testing; tan delta and partial discharge tests give a baseline for future condition checks.</p></li><li><p>Record cable routes, joint positions and test results for the life of the cable.</p></li><li><p>Plan periodic condition assessment on critical feeders.</p></li></ul><h2>Bahra Electric from BTGC</h2><p>Bahra Electric is a Saudi manufacturer of medium and high voltage power cables, low voltage and control cables, and busways. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/bahra-electric-saudi-arabia">Bahra Electric partner</a> for plants and projects. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/gas-insulated-switchgear-gis-saudi-arabia">gas-insulated switchgear</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/distribution-transformers-saudi-conditions-heat-dust-losses">distribution transformers for Saudi conditions</a>, the <a href="https://www.btc-ksa.com/electrical-power-systems-saudi-arabia">electrical power systems</a> page and the <a href="https://www.btc-ksa.com/electrical-power-systems-saudi-arabia">electrical power systems</a> page.</p><h2>Questions buyers ask</h2><p><strong>Copper or aluminium conductor?</strong> Copper is smaller and has lower losses; aluminium saves cost and weight on long feeders. Both are common at medium voltage.</p><p><strong>Why use aluminium armour on single-core cables?</strong> Steel armour around a single conductor carries induced currents and heats up; aluminium is non-magnetic.</p><p><strong>Does BTGC supply locally made cables?</strong> Yes, Bahra Electric cables are made in the Kingdom, which supports local content.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 11:48:06 +0300</pubDate></item></channel></rss>