<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/pressure-gauges/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #pressure gauges</title><description>BTGC - Knowledge Hub #pressure gauges</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/pressure-gauges</link><lastBuildDate>Wed, 18 Nov 2026 11:16:59 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Calibrating Pressure Gauges and Transmitters: Intervals, Methods and Records]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/pressure-gauge-transmitter-calibration-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/nuova-fima-pressure-gauges-diaphragm-seals.webp"/>How to calibrate pressure gauges and transmitters: reference standards, test points, as-found and as-left data, intervals and records. Nuova Fima from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_nZkKsT-xTMWl5sGKfV_KfQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_I45_yjPyQQ6_Z4v6d5zQsg" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_v2htBiUbQom7KYz5B3eC8w" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_Bx5hZb5AGhtJ094nSb0mVQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> pressure gauges and transmitters drift over time because of vibration, pulsation, heat and overpressure. Calibration compares them with a more accurate, traceable reference at several points, records how far off they were and adjusts or replaces them. Setting intervals from criticality and drift history, and keeping good records, turns calibration from a routine chore into a source of reliability data. BTGC supplies Nuova Fima pressure gauges, transmitters and diaphragm seals.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/nuova-fima-pressure-gauges-diaphragm-seals.webp" alt="Nuova Fima pressure gauges and diaphragm seals" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Plants in the Kingdom run thousands of pressure instruments, many in hot outdoor locations and on vibrating equipment. Wrong readings can hide process problems or trigger false trips.</p><h2>Calibration basics</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Step</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">What it involves</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Reference standard</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Deadweight tester or calibrator, traceable to accredited labs</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Test points</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Several points across the range, rising and falling</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">As-found data</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Readings before any adjustment, showing drift</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Adjustment</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Zero and span for transmitters, or repair or replacement for gauges</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">As-left data</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Readings after adjustment, within tolerance</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Records and labels</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Date, results, next due date and technician</td></tr></tbody></table><h2>Setting intervals</h2><ul><li><p>Start from the manufacturer guidance and the instrument accuracy class.</p></li><li><p>Shorten intervals for safety, custody transfer and critical control loops.</p></li><li><p>Lengthen intervals for stable instruments with good as-found history.</p></li><li><p>Follow proof test intervals for instruments in safety instrumented functions.</p></li><li><p>Review intervals every year using the drift data.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/chemical-reactor-petrochemical-plant.webp" alt="Petrochemical plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Practical tips</h2><ul><li><p>Check for damage, blocked impulse lines and failed diaphragm seals before calibrating.</p></li><li><p>Calibrate at the mounting position or correct for head where it matters.</p></li><li><p>Replace gauges with bent pointers or zero offset after overpressure.</p></li><li><p>Use dampening or diaphragm seals where vibration and pulsation cause drift; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/pressure-gauges-vibration-pulsation-diaphragm-seals-saudi-arabia">gauges for vibration and pulsation</a>.</p></li><li><p>Store calibration data where reliability engineers can trend it.</p></li></ul><h2>Nuova Fima from BTGC</h2><p>Nuova Fima of Italy makes pressure gauges, transmitters, switches, thermometers and diaphragm seals for oil and gas, petrochemical and power plants. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/nuova-fima-saudi-arabia">Nuova Fima partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/pressure-transmitters-selection-installation-saudi-arabia">pressure transmitter selection</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/thermowells-temperature-measurement-saudi-arabia">thermowells</a> and the <a href="https://www.btc-ksa.com/petrochemicals">petrochemicals sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>How often should pressure gauges be calibrated?</strong> It depends on criticality and history; many plants use 6 to 24 months.</p><p><strong>What does as-found data show?</strong> How much the instrument drifted since the last calibration.</p><p><strong>Does BTGC supply replacement gauges?</strong> Yes, Nuova Fima gauges, transmitters and diaphragm seals.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 07:31:47 +0300</pubDate></item><item><title><![CDATA[Pressure Gauges Under Vibration and Pulsation: Liquid Filling, Snubbers and Diaphragm Seals]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/pressure-gauges-vibration-pulsation-diaphragm-seals-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/nuova-fima-pressure-gauges-diaphragm-seals.webp"/>Why pressure gauges fail on pumps and compressors, how liquid filling, snubbers and diaphragm seals fix it, and how to select gauges to EN 837. Nuova Fima.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_ovXmnrlARImH3FTkEGXNNQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_Icb2oclXTDKVaeheiX5vWg" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_EHJDvJVpQtWckouKw_Z7lw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_bjWhKNJwV6Oh5r4KOY_SyA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> local pressure gauges look simple, but on pumps, compressors and reciprocating machines they often fail within months: the pointer flutters, the movement wears and the Bourdon tube cracks. The fixes are well known: liquid-filled cases to damp vibration, snubbers or restrictors to calm pulsation, diaphragm seals to keep corrosive, viscous or hot media out of the gauge, and correct range selection so normal pressure sits in the middle of the scale. EN 837 sets the main design and accuracy rules. BTGC supplies Nuova Fima gauges, seals and thermometers.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/nuova-fima-pressure-gauges-diaphragm-seals.webp" alt="Nuova Fima pressure gauges and diaphragm seals" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Plant operators rely on local gauges during start-up, troubleshooting and rounds. A gauge that reads wrong or has failed hides real problems, and a cracked Bourdon tube can release process fluid. In Saudi plants, heat, sun and sand add to the load on gauges installed outdoors.</p><h2>Common problems and fixes</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Problem</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Cause</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Fix</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Pointer flutter, worn movement</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Machine vibration</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Glycerine or silicone filled case; remote mounting with capillary</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Pointer swinging, cracked Bourdon tube</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Pressure pulsation from reciprocating pumps or compressors</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Snubber, restrictor screw or pulsation damper; gauge with damped movement</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Blocked or corroded element</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Corrosive, viscous, crystallising or dirty media</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Diaphragm seal with suitable wetted materials and fill fluid</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Overrange damage</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Pressure spikes or wrong range</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Range so normal pressure is in the middle third of the scale; overpressure protector</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Wrong reading in hot service</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Heat reaching the gauge</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Siphon for steam, cooling tower or diaphragm seal with capillary</td></tr></tbody></table><h2>Selection points</h2><ul><li><p>Accuracy class to EN 837-1, for example class 1.0 for process gauges and 0.25 or better for test gauges.</p></li><li><p>Case and wetted parts in stainless steel for outdoor and corrosive locations; safety pattern case with blow-out back and solid front for gas and high pressure service.</p></li><li><p>Dial size for readability from the operating position, commonly 100 or 150 mm.</p></li><li><p>Diaphragm seal fill fluid suited to the process temperature and approved for food or pharma where needed.</p></li><li><p>Sour service materials where H2S is present.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/process-piping-petrochemical-plant.webp" alt="Process piping in a petrochemical plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Maintenance and calibration</h2><ul><li><p>Calibrate on a schedule against a reference, and replace gauges that fail calibration rather than adjusting repeatedly.</p></li><li><p>Check liquid level in filled gauges and look for leaks or discoloured fill.</p></li><li><p>Inspect diaphragm seals for damage after process upsets.</p></li><li><p>Record gauge failures by location; repeat failures show where a snubber or seal is needed.</p></li><li><p>Pair local gauges with transmitters for critical points so readings can be trended; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/api-plan-53a-53b-53c-comparison-saudi-pumps">API Plan 53 seal support systems</a>.</p></li></ul><h2>Nuova Fima from BTGC</h2><p>Nuova Fima of Italy makes pressure gauges, diaphragm seals, thermometers, transmitters and switches for oil and gas, petrochemical and power plants. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/nuova-fima-saudi-arabia">Nuova Fima partner in Saudi Arabia</a>. See also the <a href="https://www.btc-ksa.com/petrochemicals">petrochemicals sector</a> and <a href="https://www.btc-ksa.com/oil-gas">oil and gas sector</a> pages.</p><h2>Questions buyers ask</h2><p><strong>Does liquid filling help with pulsation?</strong> It damps vibration and some pulsation, but strong pulsation also needs a snubber or damper.</p><p><strong>When is a diaphragm seal needed?</strong> For corrosive, viscous, crystallising, hot or hygienic media that must not enter the gauge element.</p><p><strong>Can BTGC supply gauges with calibration certificates?</strong> Yes, with factory calibration certificates and material certificates on request.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 10:25:52 +0300</pubDate></item></channel></rss>