<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/pressure-transmitters/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #pressure transmitters</title><description>BTGC - Knowledge Hub #pressure transmitters</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/pressure-transmitters</link><lastBuildDate>Wed, 18 Nov 2026 11:16:58 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Calibrating Pressure Gauges and Transmitters: Intervals, Methods and Records]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/pressure-gauge-transmitter-calibration-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/nuova-fima-pressure-gauges-diaphragm-seals.webp"/>How to calibrate pressure gauges and transmitters: reference standards, test points, as-found and as-left data, intervals and records. Nuova Fima from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_nZkKsT-xTMWl5sGKfV_KfQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_I45_yjPyQQ6_Z4v6d5zQsg" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_v2htBiUbQom7KYz5B3eC8w" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_Bx5hZb5AGhtJ094nSb0mVQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> pressure gauges and transmitters drift over time because of vibration, pulsation, heat and overpressure. Calibration compares them with a more accurate, traceable reference at several points, records how far off they were and adjusts or replaces them. Setting intervals from criticality and drift history, and keeping good records, turns calibration from a routine chore into a source of reliability data. BTGC supplies Nuova Fima pressure gauges, transmitters and diaphragm seals.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/nuova-fima-pressure-gauges-diaphragm-seals.webp" alt="Nuova Fima pressure gauges and diaphragm seals" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Plants in the Kingdom run thousands of pressure instruments, many in hot outdoor locations and on vibrating equipment. Wrong readings can hide process problems or trigger false trips.</p><h2>Calibration basics</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Step</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">What it involves</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Reference standard</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Deadweight tester or calibrator, traceable to accredited labs</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Test points</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Several points across the range, rising and falling</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">As-found data</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Readings before any adjustment, showing drift</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Adjustment</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Zero and span for transmitters, or repair or replacement for gauges</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">As-left data</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Readings after adjustment, within tolerance</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Records and labels</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Date, results, next due date and technician</td></tr></tbody></table><h2>Setting intervals</h2><ul><li><p>Start from the manufacturer guidance and the instrument accuracy class.</p></li><li><p>Shorten intervals for safety, custody transfer and critical control loops.</p></li><li><p>Lengthen intervals for stable instruments with good as-found history.</p></li><li><p>Follow proof test intervals for instruments in safety instrumented functions.</p></li><li><p>Review intervals every year using the drift data.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/chemical-reactor-petrochemical-plant.webp" alt="Petrochemical plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Practical tips</h2><ul><li><p>Check for damage, blocked impulse lines and failed diaphragm seals before calibrating.</p></li><li><p>Calibrate at the mounting position or correct for head where it matters.</p></li><li><p>Replace gauges with bent pointers or zero offset after overpressure.</p></li><li><p>Use dampening or diaphragm seals where vibration and pulsation cause drift; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/pressure-gauges-vibration-pulsation-diaphragm-seals-saudi-arabia">gauges for vibration and pulsation</a>.</p></li><li><p>Store calibration data where reliability engineers can trend it.</p></li></ul><h2>Nuova Fima from BTGC</h2><p>Nuova Fima of Italy makes pressure gauges, transmitters, switches, thermometers and diaphragm seals for oil and gas, petrochemical and power plants. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/nuova-fima-saudi-arabia">Nuova Fima partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/pressure-transmitters-selection-installation-saudi-arabia">pressure transmitter selection</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/thermowells-temperature-measurement-saudi-arabia">thermowells</a> and the <a href="https://www.btc-ksa.com/petrochemicals">petrochemicals sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>How often should pressure gauges be calibrated?</strong> It depends on criticality and history; many plants use 6 to 24 months.</p><p><strong>What does as-found data show?</strong> How much the instrument drifted since the last calibration.</p><p><strong>Does BTGC supply replacement gauges?</strong> Yes, Nuova Fima gauges, transmitters and diaphragm seals.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 07:31:47 +0300</pubDate></item><item><title><![CDATA[Pressure Transmitters in Process Plants: Selection, Installation and Calibration]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/pressure-transmitters-selection-installation-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/nuova-fima-pressure-gauges-diaphragm-seals.webp"/>How to choose and install pressure and differential pressure transmitters, use remote seals, and keep readings accurate in hot plants. Nuova Fima from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_y3bUTZ8fTXqm5B8w-Wcq7Q" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_sv-JsPu2QFOYQmoG_Ibb_Q" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_1YpO3zWzRBiJEzmNGesYCg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_hpG2wS4a1NCWvj_6e-nfqQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> pressure and differential pressure transmitters send the readings that control systems use for pressure, flow and level control and for safety trips. A transmitter is only as good as its installation: impulse lines that block or freeze, remote seals with the wrong fill fluid, and hot sun on the housing all cause errors. Choosing the right range, materials and connection, installing correctly and calibrating regularly keeps measurements trustworthy. BTGC supplies Nuova Fima transmitters, gauges and diaphragm seals.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/nuova-fima-pressure-gauges-diaphragm-seals.webp" alt="Nuova Fima pressure instruments" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Every unit in a refinery, gas plant or power station depends on hundreds of transmitters. Errors and blocked lines lead to poor control and spurious trips.</p><h2>Selection points</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Item</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">What to consider</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Measurement</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Gauge, absolute or differential pressure</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Range and turndown</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Normal value in the useful part of the range</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Wetted materials</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Suited to the fluid and to sour service if needed</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Connection</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Direct, with manifold, or with remote diaphragm seals</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Approvals</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Hazardous area certification and safety ratings for trip duties</td></tr></tbody></table><h2>Installation good practice</h2><ul><li><p>Keep impulse lines short, sloped correctly and free of pockets.</p></li><li><p>Mount transmitters below the tap for liquids and above for gas, unless seals are used.</p></li><li><p>Use remote diaphragm seals for viscous, corrosive, hot or plugging fluids; choose fill fluids for the temperature range; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/pressure-gauges-vibration-pulsation-diaphragm-seals-saudi-arabia">diaphragm seals</a>.</p></li><li><p>Shade transmitters and capillaries from direct sun to limit temperature errors.</p></li><li><p>Use manifolds for safe isolation, venting and calibration.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/process-piping-petrochemical-plant.webp" alt="Process piping" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Calibration and checks</h2><ul><li><p>Calibrate on a schedule set by criticality and drift history.</p></li><li><p>Check zero regularly on differential pressure transmitters.</p></li><li><p>Blow down or flush impulse lines on dirty services.</p></li><li><p>Compare transmitters with local gauges during rounds.</p></li><li><p>Record drift to adjust calibration intervals.</p></li></ul><h2>Nuova Fima from BTGC</h2><p>Nuova Fima of Italy makes pressure gauges, transmitters, switches, thermometers and diaphragm seals for oil and gas, petrochemical and power plants. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/nuova-fima-saudi-arabia">Nuova Fima partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/thermowells-temperature-measurement-saudi-arabia">thermowells and temperature measurement</a> and the <a href="https://www.btc-ksa.com/petrochemicals">petrochemicals sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>When are remote diaphragm seals needed?</strong> For fluids that are corrosive, viscous, hot, crystallising or that would block impulse lines.</p><p><strong>Why does sunshine affect readings?</strong> Heating changes the fill fluid volume in seals and capillaries and affects electronics, causing errors.</p><p><strong>Does BTGC supply calibrated transmitters?</strong> Yes, with factory calibration certificates.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 15:16:17 +0300</pubDate></item></channel></rss>