<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/rex-heat-exchanger/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #Rex Heat Exchanger</title><description>BTGC - Knowledge Hub #Rex Heat Exchanger</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/rex-heat-exchanger</link><lastBuildDate>Wed, 18 Nov 2026 11:17:23 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Air Heating Coils: Steam and Thermal Oil Coils for Dryers]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/air-heating-coils-steam-thermal-oil-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/chemical-reactor-petrochemical-plant.webp"/>How finned air heating coils work with steam, hot water or thermal oil: uses in dryers and air preheat, freezing, condensate drainage and fouling. Rex, BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_ROCEXgyGTpS5iHtLlqf6aQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_6b8xPgiDQlGH_nOFsUc5XQ" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_SenpOmY9S6ugjn9BBj0NPA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_RW-PrcuNJ7ROOLjnUGJnmg" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> air heating coils pass air over finned tubes carrying steam, hot water or thermal oil. They heat air for product dryers, spray dryers, combustion air preheat and building or process ventilation. Steam coils need good condensate drainage to avoid water hammer and tube damage, while thermal oil coils need care with fouling and fire risk. Finned tube design sets heat transfer and pressure drop. BTGC supplies Rex finned tube heat exchangers and coils.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/chemical-reactor-petrochemical-plant.webp" alt="Process plant with drying and heating units" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Polymer, food, fertiliser and chemical plants in the Kingdom heat large volumes of air for drying and process use, often with low-pressure steam.</p><h2>Heating media compared</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Medium</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Strengths</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Watch points</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Low-pressure steam</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">High heat transfer, steady temperature</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Condensate drainage, water hammer</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Hot water</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Gentle, easy control</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Lower temperatures only</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Thermal oil</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">High temperature at low pressure</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Oil degradation, leaks and fire risk</td></tr></tbody></table><h2>Design points</h2><ul><li><p>Size for the air flow, inlet and outlet temperatures and the heating medium conditions.</p></li><li><p>Choose fin type and spacing for dust load and cleaning; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/finned-tube-types-extruded-embedded-l-foot-saudi-arabia">finned tube types</a>.</p></li><li><p>For steam, use correct tube slope, headers and traps so condensate leaves freely.</p></li><li><p>Check air-side pressure drop against the fan.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/process-piping-petrochemical-plant.webp" alt="Steam and process piping" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Operation and upkeep</h2><ul><li><p>Keep steam traps working; flooded coils lose capacity and suffer water hammer.</p></li><li><p>Use vacuum breakers on modulated steam coils to help drainage.</p></li><li><p>Clean fins of dust and product to restore capacity.</p></li><li><p>Check thermal oil quality and look for leaks at headers.</p></li><li><p>Control steam pressure upstream; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/steam-pressure-reducing-valves-saudi-arabia">steam pressure reducing valves</a>.</p></li></ul><h2>Rex Heat Exchanger from BTGC</h2><p>Rex Heat Exchanger makes finned tube heat exchangers, including air-heating coils, and coolers for transformers, motors and compressors. BTGC supplies <a href="https://www.btc-ksa.com/Knowledge-Hub/post/rex-heat-exchanger-saudi-arabia">Rex in Saudi Arabia</a> for new and replacement units. See also <a href="https://www.btc-ksa.com/thermal-management-cooling">thermal management</a> and the <a href="https://www.btc-ksa.com/petrochemicals">petrochemicals sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Why do steam coils fail?</strong> Often from water hammer and corrosion caused by poor condensate drainage.</p><p><strong>Can a coil be replaced to existing dimensions?</strong> Yes, send the drawing or nameplate and operating data.</p><p><strong>Which fin type suits dusty air?</strong> Wider fin spacing and robust fins that tolerate cleaning.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 14:33:45 +0300</pubDate></item><item><title><![CDATA[Finned Tube Types: Extruded, Embedded, L-Foot or Welded]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/finned-tube-types-extruded-embedded-l-foot-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/large-power-transformer-radiators-cooling-fans.webp"/>Comparing finned tube types for air coolers and oil coolers: extruded, embedded, L-foot and welded fins, temperature limits and corrosion. Rex, BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_6zVQZoTUTpujcNu-CuZmNg" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_MEYtxJgXR4yO6Zfcr6MbLQ" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_6m6pclgTTvGku1Ja4ZNnmQ" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_FQvVjdj1vrCMDc-9uY-RTA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> air-cooled heat exchangers and coolers use fins to multiply the outside surface of each tube. How the fin is fixed to the tube decides its temperature limit, how well it transfers heat over the years and how it resists corrosion and cleaning damage. Extruded and embedded fins hold best in hot, corrosive or dusty conditions, while wrapped L-foot fins cost less for milder duties. BTGC supplies Rex finned tube heat exchangers and coolers.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/large-power-transformer-radiators-cooling-fans.webp" alt="Coolers and fans on a large power transformer" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Air coolers, transformer oil coolers and compressor coolers in the Kingdom work in heat, dust and, near the coast, salty air.</p><h2>Fin types compared</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Type</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">How it is made</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Typical use</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">L-foot (wrapped)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Aluminium strip wound on with a foot covering the tube</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Lower temperatures and mild atmospheres; low cost</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">KL-foot</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">L-foot fin knurled into the tube surface</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Better bond and temperature range than plain L-foot</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Embedded (G-fin)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Fin wound into a groove in the tube wall</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Higher temperatures; tube surface exposed between fins</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Extruded</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Fins formed from an aluminium sleeve around the tube</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Good bond and tube protection; favoured on coastal and corrosive sites</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Welded</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Steel fin welded to a steel tube</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Very high temperatures, heaters and economisers</td></tr></tbody></table><h2>What to consider</h2><ul><li><p>Process temperature, including upsets and steam-out.</p></li><li><p>Atmosphere: coastal salt, sulphur compounds and dust favour extruded or coated fins.</p></li><li><p>Cleaning: high-pressure water can bend thin fins, so choose fin type and density to suit.</p></li><li><p>Fin density: more fins add surface but trap dust faster.</p></li><li><p>Refinery air coolers usually follow <a href="https://www.btc-ksa.com/Knowledge-Hub/post/api-661-air-cooled-heat-exchangers-saudi-arabia">API 661</a>.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/pipeline-gosp-oil-gas-saudi-arabia.webp" alt="Oil and gas facility in Saudi Arabia" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Keeping coolers effective</h2><ul><li><p>Clean fins on a schedule, and more often after sandstorms.</p></li><li><p>Look for loss of fin-to-tube bond, seen as uneven temperatures on thermography.</p></li><li><p>Straighten bent fins and fix fan and louvre faults.</p></li><li><p>See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/air-cooled-heat-exchanger-summer-performance-saudi-arabia">summer air cooler performance</a>.</p></li></ul><h2>Rex Heat Exchanger from BTGC</h2><p>Rex Heat Exchanger makes finned tube heat exchangers, transformer oil coolers, intercoolers and motor coolers. BTGC supplies <a href="https://www.btc-ksa.com/Knowledge-Hub/post/rex-heat-exchanger-saudi-arabia">Rex in Saudi Arabia</a> for new and replacement coolers. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/transformer-radiators-motor-air-coolers-saudi-arabia">transformer radiators and motor coolers</a> and <a href="https://www.btc-ksa.com/thermal-management-cooling">thermal management and cooling</a>.</p><h2>Questions buyers ask</h2><p><strong>Which fin type suits sites near the sea?</strong> Extruded or coated fins are often chosen for coastal and corrosive air.</p><p><strong>Can a cooler be retubed with a different fin type?</strong> Often yes, once the thermal design is rechecked.</p><p><strong>Can BTGC supply a replacement cooler to existing dimensions?</strong> Yes, send the drawing or nameplate data.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 13:15:11 +0300</pubDate></item><item><title><![CDATA[Oil Coolers for Hydraulic and Lube Systems: Air-Cooled vs Water-Cooled]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/oil-coolers-hydraulic-lube-systems-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/large-power-transformer-radiators-cooling-fans.webp"/>How to choose and maintain oil coolers for hydraulic and lube systems: air-cooled vs water-cooled, sizing for Saudi heat, bypass valves and cleaning. Rex, BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_YYAuMlNfQD6YCg0WN6q6cA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_nXsY7jJbRFunjb4JxneaGg" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_XT4N3y9vQ2a4bfWQXE0alw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_ltwh3NqKpHl8BXQ3a6nh-w" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> hydraulic and lube oil systems turn part of their power into heat, and oil coolers must remove it to keep oil within its working temperature. Air-cooled coolers need no water but can only cool oil to somewhat above ambient, which is a challenge at 50 degC. Water-cooled coolers reach lower temperatures but need clean cooling water and carry a risk of water entering the oil. Correct sizing, thermostatic bypass and regular cleaning keep oil temperatures under control. BTGC supplies Rex finned tube coolers and oil coolers.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/large-power-transformer-radiators-cooling-fans.webp" alt="Finned coolers and fans" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Hydraulic presses, mobile and mining equipment, compressor and turbine lube systems and gearboxes in the Kingdom often run hot in summer, shortening oil and seal life.</p><h2>Air-cooled vs water-cooled</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Factor</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Air-cooled</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Water-cooled</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Cooling medium</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Ambient air with fans</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Plant cooling water</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Lowest oil temperature</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Ambient plus approach</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Close to water temperature</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Water risk</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">None</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Leaks can contaminate oil</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Maintenance</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Fin cleaning, fans</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Tube cleaning, water treatment</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Best for</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Remote and water-scarce sites</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Plants with good cooling water</td></tr></tbody></table><h2>Sizing points</h2><ul><li><p>Calculate heat load from system power and efficiency, not just pump size.</p></li><li><p>Use the real maximum ambient or water temperature.</p></li><li><p>Allow for fouling and dust on fins.</p></li><li><p>Fit thermostatic bypass valves so cold oil bypasses the cooler at start-up.</p></li><li><p>Check pressure drop limits for the oil circuit.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/pipeline-gosp-oil-gas-saudi-arabia.webp" alt="Industrial facility" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Maintenance tips</h2><ul><li><p>Clean fins regularly from the clean side outward.</p></li><li><p>Check fans, belts and motors.</p></li><li><p>Watch oil temperatures and the difference across the cooler.</p></li><li><p>Test water-cooled units for leaks and check oil for water.</p></li><li><p>Keep oil clean; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/hydraulic-oil-hot-climate-saudi-arabia">hydraulic oil in hot climates</a>.</p></li></ul><h2>Rex from BTGC</h2><p>Rex Heat Exchanger of India makes radiators, finned tube coolers, intercoolers and aftercoolers for generator sets, transformers, motors and compressors. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/rex-heat-exchanger-saudi-arabia">Rex partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/generator-set-radiators-desert-cooling-saudi-arabia">generator set radiators</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/lube-oil-seal-oil-systems-compressors-turbines-saudi-arabia">lube oil systems</a> and the <a href="https://www.btc-ksa.com/power-utilities">power and utilities sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Can an air-cooled cooler cool oil below ambient?</strong> No, it can only cool to somewhat above the ambient air temperature.</p><p><strong>Why fit a thermostatic bypass?</strong> It lets cold oil warm up quickly and protects the cooler from high pressure at start-up.</p><p><strong>Does BTGC supply replacement oil coolers?</strong> Yes, Rex coolers built to fit existing systems.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 08:23:09 +0300</pubDate></item><item><title><![CDATA[Generator Set Radiators: Cooling Diesel Gensets in Desert Conditions]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/generator-set-radiators-desert-cooling-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/large-power-transformer-radiators-cooling-fans.webp"/>Why diesel genset radiators overheat in Saudi heat and dust, how to size, clean and protect them, and when to replace or upgrade them. Rex radiators from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_uHBnM12USjy5QUHuk_WW1w" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_uWCSrP4bSlCemjuzS9GbiA" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_Ol1HJtMnRrW7l-vT6zhaMg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_JYXw6XsU88mpP0dz9ZQW-w" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> diesel generator sets provide prime and standby power at remote sites, construction projects, telecom stations and plants across the Kingdom. Their radiators must reject large amounts of heat at ambient temperatures that can exceed 50 degC, while dust and sand clog the fins. Undersized or fouled radiators cause overheating, derating and shutdowns, often at the worst possible moment. Correct sizing, cleaning and timely replacement keep gensets running. BTGC supplies Rex radiators and coolers.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/large-power-transformer-radiators-cooling-fans.webp" alt="Radiators and cooling fans" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Gensets in the Kingdom often run during the hottest hours, when grid demand peaks or when they are the only power source. Cooling capacity is the most common limit on their output.</p><h2>Why genset radiators struggle</h2><ul><li><p>Standard radiators are often rated for lower ambient temperatures than the site sees.</p></li><li><p>Dust and sand block fins and cut air flow.</p></li><li><p>Radiators can be placed where hot exhaust or other equipment heats the cooling air.</p></li><li><p>Coolant quality problems cause scaling and corrosion inside the tubes.</p></li><li><p>Fan belts, fans and shrouds wear or break.</p></li></ul><h2>Sizing and selection points</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Point</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">What to check</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Ambient rating</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Radiator rated for the real maximum site temperature</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Altitude and air density</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Affects cooling at high altitude sites</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Fin spacing and material</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Wider spacing resists clogging in dusty areas</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Enclosure airflow</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Inlet and outlet openings sized for the air flow</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Coolant system</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Correct coolant mix and inhibitors</td></tr></tbody></table><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/oil-gas-facility-saudi-arabia.webp" alt="Remote industrial site" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Maintenance tips</h2><ul><li><p>Clean fins regularly with air or low-pressure water from the clean side.</p></li><li><p>Check coolant level, concentration and condition.</p></li><li><p>Inspect hoses, fans, belts and shrouds.</p></li><li><p>Pressure test radiators for leaks during service.</p></li><li><p>Replace or upgrade radiators that cannot hold temperature in summer.</p></li></ul><h2>Rex from BTGC</h2><p>Rex Heat Exchanger of India makes radiators, finned tube coolers, intercoolers and aftercoolers for generator sets, transformers, motors and compressors. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/rex-heat-exchanger-saudi-arabia">Rex partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/transformer-radiators-motor-air-coolers-saudi-arabia">transformer radiators and motor coolers</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/generator-load-bank-connections-plugs-saudi-arabia">generator load bank connections</a> and the <a href="https://www.btc-ksa.com/power-utilities">power and utilities sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Why does my genset derate in summer?</strong> Its cooling system cannot reject enough heat at high ambient, often made worse by dirty fins.</p><p><strong>Can a radiator be upgraded on an existing genset?</strong> Often yes, with a higher-capacity core that fits the available space.</p><p><strong>Does BTGC supply replacement radiators?</strong> Yes, Rex radiators built to fit existing gensets.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 16:34:00 +0300</pubDate></item><item><title><![CDATA[Compressor Intercoolers and Aftercoolers: Fouling, Leaks and Performance]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/compressor-intercoolers-aftercoolers-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/shell-and-tube-heat-exchanger-tubesheet.webp"/>How compressor intercoolers and aftercoolers affect power and air quality, what fouls them, and how to clean, test and replace them. Rex from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_rlUOas4mTgWI7jb9ALksKw" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_qh-c8FAmRwWXLhrKaGdNVg" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_mPT6BxJwR6mxNHLC6o2nwg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_BPBfD1xvSZy7Y5VybycGXw" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> multistage compressors cool the gas between stages in intercoolers and after the last stage in aftercoolers. Good cooling cuts the power needed for the next stage, protects valves and seals from high temperature, and condenses water out of compressed air. Fouled tubes, leaks and blocked fins quietly raise power and temperatures, and in summer can force compressors to unload or trip. Regular cleaning, testing and timely replacement keep compressors efficient. BTGC supplies Rex intercoolers, aftercoolers and finned tube coolers.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/shell-and-tube-heat-exchanger-tubesheet.webp" alt="Shell and tube heat exchanger tubesheet" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Reciprocating and centrifugal compressors for air, gas lift, fuel gas and process gas in the Kingdom work hardest in summer, exactly when coolers are least effective because of high air and water temperatures.</p><h2>Why cooler condition matters</h2><ul><li><p>Higher gas temperature into the next stage means more compression power.</p></li><li><p>High discharge temperatures shorten valve, ring and seal life on reciprocating compressors.</p></li><li><p>Poor aftercooling sends more water vapour to dryers and the air network.</p></li><li><p>Leaks between gas and water sides contaminate cooling water or let water into the compressor.</p></li></ul><h2>Common problems</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Problem</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Cause</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Scaling and fouling on water side</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Hard or untreated cooling water, low velocity</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Fouling on gas side</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Oil carry-over, dust, process deposits</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Blocked fins on air-cooled units</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Dust and sand</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Tube leaks</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Corrosion, vibration, erosion at inlets</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Rising approach temperature</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Combined effect of fouling and lower flow</td></tr></tbody></table><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/pipeline-gosp-oil-gas-saudi-arabia.webp" alt="Gas compression facility" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Cleaning, testing and replacement</h2><ul><li><p>Trend gas outlet temperature and approach to cooling water temperature.</p></li><li><p>Clean water sides mechanically or chemically, and improve water treatment; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/cooling-tower-water-cycles-concentration-saudi-arabia">cooling water cycles</a>.</p></li><li><p>Clean air-cooled fins before summer.</p></li><li><p>Pressure test for leaks at overhauls and plug or retube as needed.</p></li><li><p>Replace coolers with improved materials or designs when leaks repeat.</p></li></ul><h2>Rex from BTGC</h2><p>Rex Heat Exchanger of India makes finned tube heat exchangers, radiators, intercoolers and aftercoolers for compressors, engines, transformers and motors. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/rex-heat-exchanger-saudi-arabia">Rex partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/transformer-radiators-motor-air-coolers-saudi-arabia">transformer radiators and motor coolers</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/instrument-air-quality-dryers-iso-8573-saudi-arabia">instrument air quality</a> and the <a href="https://www.btc-ksa.com/rotating-equipment">rotating equipment</a> page.</p><h2>Questions buyers ask</h2><p><strong>How do I know my intercooler is fouled?</strong> Gas outlet temperature rises for the same cooling water temperature, and compressor power increases.</p><p><strong>Can coolers be replaced with a different design?</strong> Yes, if thermal duty, pressure ratings and connections are matched.</p><p><strong>Does BTGC supply coolers to existing dimensions?</strong> Yes, Rex can build to match existing coolers.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 14:24:04 +0300</pubDate></item><item><title><![CDATA[Transformer Radiators and Motor Air Coolers: Cleaning, Leaks and Replacement]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/transformer-radiators-motor-air-coolers-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/weg-water-cooled-electric-motor-saudi-arabia.webp"/>How fouled or leaking transformer radiators and motor air coolers raise temperatures, how to clean and test them, and when to replace them. Rex from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_ofLlchW4Qg-DyYdib_IIaw" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_JsNI8KpPR2qd13P-vYyvxg" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_hzBwt-D_S22pM4PgSz-atA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_5LNQT_NuUBDOPZzOr_mbFA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> large transformers and motors depend on their coolers to stay within temperature limits. Transformer radiators cool the oil, and motors use air-to-air (CACA) or air-to-water (CACW) coolers mounted on the machine. Dust, sand and salt reduce heat transfer, and leaking tubes in water-cooled motor coolers can put water into the windings. Regular cleaning, leak testing and timely replacement keep machines from overheating and ageing early. BTGC supplies Rex finned tube coolers and radiators.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/weg-water-cooled-electric-motor-saudi-arabia.webp" alt="Water-cooled electric motor with top-mounted cooler" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Sand and dust storms, coastal humidity and high summer temperatures in the Kingdom put coolers under constant stress. A cooler that has lost a fraction of its capacity may go unnoticed until the hottest weeks of the year, when the machine trips or runs over temperature.</p><h2>Where coolers are used</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Equipment</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Cooler type</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Oil-filled transformers</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Radiators with natural (ONAN) or fan (ONAF) air flow</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Large motors and generators, air-cooled</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Air-to-air tube coolers (CACA) on top of the machine</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Large motors and generators, water-cooled</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Air-to-water coolers (CACW) with leak detection</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Gear units and lube oil systems</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Finned tube or shell and tube oil coolers</td></tr></tbody></table><h2>Signs a cooler needs attention</h2><ul><li><p>Winding, oil or bearing temperatures rising year on year at the same load.</p></li><li><p>Visible dust or sand packed between fins.</p></li><li><p>Corrosion of fins and tube sheets, especially near the coast.</p></li><li><p>Leak detector alarms or damp marks on water-cooled motor coolers.</p></li><li><p>Cooling fans not running or running slowly.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/large-power-transformer-radiators-cooling-fans.webp" alt="Transformer radiators and cooling fans" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Cleaning, testing and replacement</h2><ul><li><p>Clean fins with compressed air or low-pressure water from the clean side, without bending fins.</p></li><li><p>Pressure test water-cooled coolers at overhauls and repair or plug leaking tubes.</p></li><li><p>Check fans, motors and thermostats on transformer cooling systems before summer.</p></li><li><p>Replace coolers that have lost too much capacity or have repeated leaks; choose tube and fin materials suited to the water and air quality.</p></li><li><p>Make sure replacements match thermal rating and mounting dimensions.</p></li></ul><h2>Rex from BTGC</h2><p>Rex Heat Exchanger of India makes finned tube heat exchangers, radiators and coolers for transformers, motors, generators and compressors. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/rex-heat-exchanger-saudi-arabia">Rex partner in Saudi Arabia</a>, with full electric motor services at the Jubail service center. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/water-cooled-electric-motors-saudi-arabia">water-cooled electric motors</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/transformer-loading-high-ambient-saudi-arabia">transformer loading in high ambient</a> and <a href="https://www.btc-ksa.com/Knowledge-Hub/post/air-fin-coolers-air-cooled-heat-exchangers-saudi-arabia">air fin coolers</a>.</p><h2>Questions buyers ask</h2><p><strong>How often should transformer radiators be cleaned?</strong> At least before each summer, and more often on dusty or coastal sites.</p><p><strong>Can a leaking CACW cooler be repaired?</strong> Often yes, by plugging or replacing tubes, but repeated leaks usually mean replacement is due.</p><p><strong>Does BTGC supply replacement coolers for other brands?</strong> Yes, Rex can build coolers to match existing dimensions and ratings.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 12:00:57 +0300</pubDate></item><item><title><![CDATA[Rex Heat Exchanger in Saudi Arabia: Finned Tube Exchangers]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/rex-heat-exchanger-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/large-power-transformer-radiators-cooling-fans.webp"/>Rex finned tube heat exchangers, transformer oil coolers and compressor intercoolers for Saudi plants, supplied by BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_KRm4yXNaS-qQFlvGWUtwCA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_ECXDfd5sSIKu4c5qUVM8Kw" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_TXOLTqN_RMua5LQzseZySQ" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_47WNRHLfNO5eqdW7kgtxlA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>BTGC partner · India.</strong> Rex Heat Exchanger is an Indian manufacturer of finned tube heat exchangers and coolers for electrical and rotating equipment. BTGC partners with Rex in Saudi Arabia for new and replacement coolers.</p></blockquote><h2>Rex Heat Exchanger product range from BTGC</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Product</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">What it covers</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;"><strong>Finned tube heat exchangers</strong></td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Air-cooled and air-heating coils and exchangers.</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;"><strong>Transformer oil coolers</strong></td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Oil-to-air and oil-to-water coolers for power transformers.</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;"><strong>Intercoolers and motor coolers</strong></td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Coolers for compressors, motors and generators.</td></tr></tbody></table><h2>Where Rex Heat Exchanger is used in Saudi Arabia</h2><ul><li><p><strong><a href="https://www.btc-ksa.com/power-utilities">Power &amp; Utilities</a></strong>: Transformer, generator and motor cooling.</p></li><li><p><strong><a href="https://www.btc-ksa.com/petrochemicals">Petrochemicals</a></strong>: Compressor intercoolers and aftercoolers.</p></li><li><p><strong><a href="https://www.btc-ksa.com/metal-sector">Metals &amp; Steel</a></strong>: Coolers for large drives.</p></li></ul><h2>BTGC local support for Rex Heat Exchanger</h2><ul><li><p><strong>One local contact</strong>: enquiries, quotations and order follow-up through BTGC branches in Dammam, Jubail and Yanbu.</p></li><li><p><strong>Engineering and selection</strong>: data sheet review, sizing and like-for-like replacement of installed units.</p></li><li><p><strong>Service center in Jubail</strong>: valve testing and repair, full electric motor services and the WEG approved service center in Saudi Arabia.</p></li><li><p><strong>Documentation</strong>: certificates, test reports and vendor documents prepared to the project specification.</p></li></ul><h2>Rex articles in the Knowledge Hub</h2><ul><li><p><a href="https://www.btc-ksa.com/Knowledge-Hub/post/oil-coolers-hydraulic-lube-systems-saudi-arabia">Oil Coolers for Hydraulic and Lube Systems: Air-Cooled vs Water-Cooled</a></p></li><li><p><a href="https://www.btc-ksa.com/Knowledge-Hub/post/generator-set-radiators-desert-cooling-saudi-arabia">Generator Set Radiators: Cooling Diesel Gensets in Desert Conditions</a></p></li><li><p><a href="https://www.btc-ksa.com/Knowledge-Hub/post/compressor-intercoolers-aftercoolers-saudi-arabia">Compressor Intercoolers and Aftercoolers: Fouling, Leaks and Performance</a></p></li><li><p><a href="https://www.btc-ksa.com/Knowledge-Hub/post/transformer-radiators-motor-air-coolers-saudi-arabia">Transformer Radiators and Motor Air Coolers: Cleaning, Leaks and Replacement</a></p></li><li><p><a href="https://www.btc-ksa.com/Knowledge-Hub/post/finned-tube-types-extruded-embedded-l-foot-saudi-arabia">Finned Tube Types: Extruded, Embedded, L-Foot or Welded</a></p></li><li><p><a href="https://www.btc-ksa.com/Knowledge-Hub/post/air-heating-coils-steam-thermal-oil-saudi-arabia">Air Heating Coils: Steam and Thermal Oil Coils for Dryers</a></p></li></ul><h2>Related partners and pages</h2><ul><li><p><a href="https://www.btc-ksa.com/process-separation">Thermal Management &amp; Cooling solutions</a></p></li><li><p><a href="https://www.btc-ksa.com/kelvion-saudi-arabia">Kelvion in Saudi Arabia</a></p></li><li><p><a href="https://www.btc-ksa.com/hemaco-saudi-arabia">Hemaco in Saudi Arabia</a></p></li><li><p><a href="https://www.btc-ksa.com/partners">All BTGC partners</a></p></li></ul><h2>Talk to BTGC about Rex Heat Exchanger</h2><p>Email <a href="mailto:info@btc-ksa.com">info@btc-ksa.com</a> or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Sun, 15 Nov 2026 13:00:31 +0300</pubDate></item></channel></rss>