<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/roll-force/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #roll force</title><description>BTGC - Knowledge Hub #roll force</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/roll-force</link><lastBuildDate>Wed, 18 Nov 2026 11:16:20 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Calibrating Roll Force and Strip Tension Systems in Rolling Mills]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/rolling-mill-load-cell-calibration-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/kelk-roll-force-measurement-system-rolling-mill.webp"/>Why roll force load cells and tensiometers drift, how mills calibrate them and what a good maintenance routine looks like. Kelk measurement systems from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_Mv_K4DbRRlKO3m5UqxIFDg" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_lD_ECxrcRNiFUhj6VMs2gQ" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_HvfQvaKZR6G090dXpGm4LQ" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_r_Hv2Or6KZ2DEK0UScNiMQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> gauge control, mill setup models and strip tension loops all trust the numbers from the load cells under the rolls. When those numbers drift, the mill corrects in the wrong direction: off-gauge heads and tails, poor flatness, strip breaks and mill stretch errors. Routine checks of zero, side-to-side balance and cabling, and a full calibration at planned shutdowns, keep the measurements honest. BTGC supplies Kelk roll force and tension systems and supports calibration for Saudi steel and aluminium mills.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/kelk-roll-force-measurement-system-rolling-mill.webp" alt="Kelk roll force measurement system for rolling mills" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Roll force load cells sit in one of the harshest places in a plant: under the screwdown or hydraulic cylinder, carrying millions of load cycles, flooded with roll coolant, emulsion or scale, and exposed to heat from the strip. Tensiometer load cells under deflector rolls face similar conditions. They are built for it, but no measurement stays accurate for ever without checks.</p><h2>Why mill measurements drift</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Cause</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Effect on the reading</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Water or coolant in the cell or connector</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Unstable zero, noise, insulation faults</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Damaged or crushed cables</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Intermittent signals, offset changes</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Uneven seating or a distorted bearing block</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Load shared unevenly; wrong force reading on one side</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Overload or impact from cobbles and strip breaks</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Permanent zero shift</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Temperature changes</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Zero drift if the cell or electronics are not compensated</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Electronics ageing</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Gain and offset errors in the amplifier or transmitter</td></tr></tbody></table><h2>Routine checks between shutdowns</h2><ul><li><p><strong>Zero check.</strong> Record the reading with the mill open and unloaded at the same point in every shift or roll change, and trend it: a slow change shows a developing fault.</p></li><li><p><strong>Side-to-side comparison.</strong> Operator side and drive side cells should read alike on a centred, flat strip. A growing difference points to a cell, cable or mechanical problem.</p></li><li><p><strong>Cross-check against hydraulics.</strong> On hydraulic gap control mills, compare load cell force with the force calculated from cylinder pressure; a divergence flags one of the two.</p></li><li><p><strong>Insulation and cable tests.</strong> Measure insulation resistance of cells and cables at roll changes and inspect cable routes for damage.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/kelk-rolling-mill-sensors-range.webp" alt="Kelk rolling mill sensors: load cells, tensiometers and gauges" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Calibration at planned shutdowns</h2><p>Roll force systems are calibrated with a reference load in the mill window, typically a calibrated reference load cell or calibration jack placed in the stand, with the mill's own cylinders applying load in steps up to the working range and back down. Each step is compared and the gain is set. Tensiometers are calibrated with known weights hung on a sling over the roll at the design wrap angle, or with a calibrated force applied along the strip path. The records, with zero and span before and after, are the evidence the quality system needs.</p><h2>Mill stretch and gauge control</h2><p>Load cell force also feeds the mill stretch calculation: the stand stretches in proportion to force, and the gauge control system uses that to correct the roll gap. A force error of a few per cent becomes a thickness error the gauge meter cannot see. That is why roll force calibration belongs in the commissioning of any new gauge control model, together with the speed measurement described in <a href="https://www.btc-ksa.com/Knowledge-Hub/post/laser-velocimeter-hot-strip-mill-saudi-arabia">laser velocimeters</a>.</p><h2>Spares and repair</h2><ul><li><p>Keep at least one spare cell for each critical position, stored dry with protective caps.</p></li><li><p>Replace connectors and cable sections with the manufacturer's parts to keep sealing and shielding intact.</p></li><li><p>Send suspect cells for test and recalibration rather than re-zeroing them in the mill and hiding a fault.</p></li></ul><h2>Kelk from BTGC</h2><p>Kelk, part of Vishay Precision Group, builds ROLLMAX roll force systems, TENSIOMETER strip tension systems, laser velocimeters and other measurement equipment for rolling mills. BTGC is the <a href="https://www.btc-ksa.com/kelk-saudi-arabia">Kelk partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/roll-force-load-cells-rolling-mill-saudi-arabia">roll force load cells</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/strip-tension-measurement-tensiometers-saudi-arabia">strip tension measurement</a> and the <a href="https://www.btc-ksa.com/metal-sector">metals and steel sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>How often should roll force cells be calibrated?</strong> Typically at each major shutdown, with zero and side-to-side checks every shift or roll change; the trend decides whether more frequent calibration is needed.</p><p><strong>Can a cell damaged by a cobble be repaired?</strong> It must be tested first; a permanent zero shift or an insulation fault usually means replacement or factory repair.</p><p><strong>Can BTGC support a calibration during our shutdown?</strong> Yes. BTGC coordinates calibration equipment and support with Kelk; book early so it fits the shutdown plan.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Mon, 16 Nov 2026 09:57:12 +0300</pubDate></item><item><title><![CDATA[Roll Force Load Cells in Saudi Rolling Mills]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/roll-force-load-cells-rolling-mill-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/kelk-roll-force-measurement-system-rolling-mill.webp"/>What the roll force load cell does for gauge control and stand protection, and how to plan replacement. Kelk ROLLMAX systems from BTGC for Saudi mills.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_5Mz6490NQbuYHo-g4b6CNQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_nQu2mU1gSPG6JZOumEZLAw" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_bQ59tkm8SVqk6PzZIrGhIA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_WkIkQP5u-KSauPTdj9f-fA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> the roll force load cell is the one sensor a rolling mill cannot run without: it feeds the automatic gauge control, protects the stand from overload and tells the operator what the mill is doing. Kelk ROLLMAX load cells are built for the shock, heat and scale of roughing and finishing stands and are the reference in mills worldwide. BTGC supplies and supports them for Saudi steel and aluminium mills.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/kelk-roll-force-measurement-system-rolling-mill.webp" alt="Kelk roll-force measurement system in a rolling mill" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Hadeed's flat and long product mills, the aluminium rolling mills at Ras Al Khair and the rebar mills across the Kingdom all depend on the same measurement: the force each stand applies to the metal. That force sets the gauge, the shape and the roll wear, and when it goes wrong the mill either makes scrap or breaks something expensive. Measuring it reliably in a mill housing, under thousands of tonnes of load, with scale, water and heat all around, is a specialised job.</p><h2>Where the load cell sits and what it sees</h2><p>Roll force load cells are mounted under the screw-down (or hydraulic capsule) or under the bottom backup roll chocks, so the full separating force passes through them. A roughing stand can see 40 MN or more, applied in a fraction of a second as the bar enters, with a shock each time the head end hits the rolls. The cell has to resolve small changes in that force for the gauge control loop while surviving the overload of a cobble.</p><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Requirement</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Kelk ROLLMAX design answer</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Shock and overload</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Forged alloy steel bodies with overload capacity well above rated load, no moving parts</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Off-centre and side loads</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Strain gauge arrangement that cancels bending and eccentric loading</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Heat, water, scale</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Hermetically sealed, temperature compensated, armoured cabling</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Long-term accuracy</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Calibration traceable to national standards, drift specified over years not months</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Mill integration</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Electronics with analogue and digital outputs to the mill automation, operator displays</td></tr></tbody></table><h2>What good roll force data buys the mill</h2><ul><li><p><strong>Gauge and shape</strong>: the automatic gauge control uses roll force and gap to hold strip thickness; noisy or drifting force readings show up as thickness variation and off-gauge coil ends.</p></li><li><p><strong>Roll and bearing protection</strong>: force limits and left-right balance alarms stop the stand before a chock or bearing is damaged.</p></li><li><p><strong>Pass schedule optimisation</strong>: measured force per pass lets the process team run closer to the mill's capability.</p></li><li><p><strong>Condition monitoring</strong>: a change in the force signature at constant draft points to roll wear, lubrication problems or bearing damage.</p></li></ul><h2>Replacing and upgrading load cells</h2><p>Many Saudi mills still run the load cells installed with the mill twenty or thirty years ago. Replacement is planned around a roll change or a stand rebuild, with the new cells dimensioned to fit the existing pockets and the electronics upgraded to the current automation interface. Kelk also refurbishes and recalibrates its own cells, and BTGC organises the logistics, the customs and the on-site support from Dammam. The companion measurement on hot strip mills, laser speed and length, is covered in the earlier article on <a href="https://www.btc-ksa.com/Knowledge-Hub/post/laser-velocimeter-hot-strip-mill-saudi-arabia">laser velocimeters</a>.</p><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/kelk-rolling-mill-sensors-range.webp" alt="Kelk rolling mill sensors: load cells, tensiometers and gauges" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Kelk from BTGC</h2><p>Kelk, Toronto, part of Vishay Precision Group, has specialised in rolling mill measurement for about seventy years: ROLLMAX roll force systems, TENSIOMETER strip tension systems, ACCUSPEED laser velocimeters and ACCUBAND width gauges. BTGC is the <a href="https://www.btc-ksa.com/kelk-saudi-arabia">Kelk partner in Saudi Arabia</a>, supporting steel and aluminium mills with new systems, calibration, spares and refurbishment. See the <a href="https://www.btc-ksa.com/machinery-handling">mining and material handling</a> page and the <a href="https://www.btc-ksa.com/metal-sector">metals and steel sector page</a>.</p><h2>Questions buyers ask</h2><p><strong>How often should load cells be recalibrated?</strong> Kelk cells hold calibration for years; most mills verify them at major shutdowns with a calibration cell or by comparison between stands.</p><p><strong>Can Kelk cells replace another maker's cells?</strong> Yes; Kelk designs to the existing pocket dimensions and output signal, and BTGC coordinates the survey.</p><p><strong>What lead time should we expect?</strong> Custom cells are typically 16 to 24 weeks; BTGC advises ordering spares with the main set.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Sun, 15 Nov 2026 08:35:53 +0300</pubDate></item></channel></rss>