<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/sfra/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #SFRA</title><description>BTGC - Knowledge Hub #SFRA</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/sfra</link><lastBuildDate>Wed, 18 Nov 2026 04:44:53 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Transformer Commissioning Tests: What to Check Before Energising]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/transformer-commissioning-tests-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/arabian-transformers-distribution-transformer.webp"/>Which tests to run before energising a transformer: oil, insulation, winding resistance, ratio, vector group, SFRA and protection. ATC, BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_PG43Dhh4QwCbEB1QFtOHFQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_XfjY5689TCi8WMsLtAgEQg" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_V4RbOC-JQ228TShshS5VCg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_pLYXiLcO3DC7uNVqvbgyJw" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> a transformer can be damaged during transport, storage or installation, and wiring or protection mistakes can cause trouble on first energising. Commissioning tests check oil quality, insulation, windings, ratio and vector group, and confirm that protection devices and controls work. They also record a baseline, such as SFRA and DGA results, that future tests are compared with. BTGC supplies Arabian Transformers Company transformers and supports their commissioning.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/arabian-transformers-distribution-transformer.webp" alt="Arabian Transformers distribution transformer" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>New substations, industrial plants, solar farms and giga-projects in the Kingdom commission large numbers of transformers. A careful first energising prevents early failures and disputes.</p><h2>Typical commissioning tests</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Test</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Checks</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Visual and mechanical</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Damage, leaks, earthing, clearances, accessories</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Oil tests</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Breakdown voltage, moisture and baseline DGA</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Insulation resistance and PI</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Overall insulation condition</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Winding resistance</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Connections and tap changer contacts</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Turns ratio and vector group</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Correct ratio on all taps and correct phase shift</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">SFRA</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Baseline for future checks of winding movement</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Protection and controls</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Buchholz, pressure relief, temperature devices, CTs and alarms</td></tr></tbody></table><h2>Before energising</h2><ul><li><p>Check transport shock recorder results for large units.</p></li><li><p>Confirm oil levels and that valves to radiators and conservator are open.</p></li><li><p>Vent air from radiators, bushings and Buchholz relay.</p></li><li><p>Check tap position and control settings.</p></li><li><p>Confirm protection settings and trip tests.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/desalination-plant-saudi-arabia.webp" alt="Utility plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>First energising and after</h2><ul><li><p>Energise with protection in service and observe for noise, heating and alarms.</p></li><li><p>Hold a soak period before loading where specified.</p></li><li><p>Take oil samples after a set period for DGA comparison; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/transformer-oil-testing-dga-saudi-arabia">oil testing and DGA</a>.</p></li><li><p>Record all results in a commissioning report.</p></li><li><p>Plan routine tests; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/transformer-protection-buchholz-pressure-relief-saudi-arabia">transformer protection</a>.</p></li></ul><h2>Arabian Transformers from BTGC</h2><p>Arabian Transformers Company (ATC) manufactures distribution and power transformers, compact substations and package units in the Kingdom. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/arabian-transformers-saudi-arabia">ATC partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/dry-type-vs-oil-immersed-transformers-saudi-arabia">dry-type vs oil-immersed transformers</a>, the <a href="https://www.btc-ksa.com/electrical-power-systems-saudi-arabia">electrical power systems</a> page and the <a href="https://www.btc-ksa.com/power-utilities">power and utilities sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Why record an SFRA baseline?</strong> Later tests can be compared with it to detect winding movement after faults or transport.</p><p><strong>Do repaired transformers need commissioning tests?</strong> Yes, the same checks apply after major repairs.</p><p><strong>Does BTGC support transformer commissioning?</strong> Yes, with ATC transformers and testing coordination.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 09:02:09 +0300</pubDate></item></channel></rss>