<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/solar-pv/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #solar PV</title><description>BTGC - Knowledge Hub #solar PV</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/solar-pv</link><lastBuildDate>Wed, 18 Nov 2026 11:16:59 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Transformers for Solar PV Plants: Inverter Duty, Harmonics and Desert Heat]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/transformers-solar-pv-plants-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/arabian-transformers-distribution-transformer.webp"/>What solar PV plants need from step-up transformers: inverter-duty design, harmonics, daily load cycles, desert heat and dust, and local supply. ATC from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_Rs7zyZAxRdi2vi895wXK8A" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_I83zOoZSRVmtaRBHdGVwIw" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_RjU4u5s4SGmro45vNVXs0A" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_rFjQOb1nLRLTEVkIOUQA5w" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> large solar PV plants collect power from inverters at low voltage and step it up to medium voltage through inverter or station transformers, and then to transmission voltage at the main substation. These transformers see harmonics from inverters, a daily load cycle that peaks in the hottest hours, and harsh desert conditions. Designing them for inverter duty, heat and dust, and sourcing them locally, supports reliable output and local content targets. BTGC supplies Arabian Transformers (ATC) transformers made in the Kingdom.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/arabian-transformers-distribution-transformer.webp" alt="Arabian Transformers transformer" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>The Kingdom is building gigawatts of solar PV capacity, many in remote desert locations. Each plant uses large numbers of medium voltage transformers that must run reliably for decades.</p><h2>What makes PV transformers different</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Factor</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Design response</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Inverter harmonics</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Windings and losses designed for harmonic currents; shielding between windings where specified</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Multiple inverters on one unit</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Multi-winding designs in some plants</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Peak load at peak heat</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Thermal design for maximum ambient and solar radiation</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Daily cycling</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Insulation and mechanical design for repeated heating and cooling</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Dust and sand</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Sealed tanks, suitable radiators and cleaning access</td></tr></tbody></table><h2>Specification points</h2><ul><li><p>Rating at the real site ambient and with solar gain on the tank; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/distribution-transformers-saudi-conditions-heat-dust-losses">transformers for Saudi conditions</a>.</p></li><li><p>Loss requirements and efficiency rules.</p></li><li><p>Insulating liquid: mineral oil or ester for fire safety.</p></li><li><p>Protection and monitoring: temperature, oil level, pressure relief and gas relay.</p></li><li><p>Compact substation packaging where suitable; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/compact-substations-package-units-saudi-arabia">compact substations</a>.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/large-power-transformer-radiators-cooling-fans.webp" alt="Transformer radiators" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Operation and maintenance</h2><ul><li><p>Clean radiators and check fans before summer.</p></li><li><p>Take oil samples for DGA and moisture on a schedule; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/transformer-oil-testing-dga-saudi-arabia">oil testing</a>.</p></li><li><p>Check gaskets and seals for leaks caused by daily cycling.</p></li><li><p>Monitor temperatures remotely across the plant.</p></li><li><p>Keep spare units for fast replacement in large plants.</p></li></ul><h2>Arabian Transformers from BTGC</h2><p>Arabian Transformers Company (ATC) manufactures distribution and power transformers, compact substations and package units in the Kingdom. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/arabian-transformers-saudi-arabia">ATC partner in Saudi Arabia</a>. See also the <a href="https://www.btc-ksa.com/electrical-power-systems-saudi-arabia">electrical power systems</a> page and the <a href="https://www.btc-ksa.com/power-utilities">power and utilities sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Can a standard distribution transformer be used for PV?</strong> Only if it is rated for the harmonics, load cycle and ambient; inverter-duty designs are safer.</p><p><strong>Why consider ester fluids?</strong> They have higher fire points and are biodegradable, useful at some sites.</p><p><strong>Does ATC supply transformers for solar projects?</strong> Yes, ATC manufactures transformers for utility and renewable projects in the Kingdom.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 15:18:17 +0300</pubDate></item></channel></rss>