<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/stellite/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #Stellite</title><description>BTGC - Knowledge Hub #Stellite</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/stellite</link><lastBuildDate>Wed, 18 Nov 2026 11:16:35 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Hard-Faced Gate Valves Under Thermal Shock in Saudi Plants]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/hard-faced-gate-valves-thermal-shock-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/okano-hard-faced-gate-valve-gear-operated.webp"/>Why seat hard-facing cracks on high-temperature gate valves and how to inspect and repair it. Okano Valve forged and cast valves from BTGC in Saudi Arabia.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_l37OXwRYRvmjR8VWQFLPUQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_raqq1SsaQuyt4gllWSOw0g" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_qbrNIvprQ_iinWbUfFqO8w" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_oBuFGucWLaabSq46pWEAtw" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> a main steam gate valve that passes after a few start-ups has usually cracked its seat hard-facing under thermal shock. Base metal, hard-facing alloy, welding procedure and heat treatment decide whether the seat survives 540 &deg;C steam and cold start-ups. BTGC supplies Okano Valve forged and cast gate and globe valves with Stellite hard-facing for Saudi power plants and process steam systems.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/okano-hard-faced-gate-valve-gear-operated.webp" alt="Okano Valve gear-operated high-temperature gate valve" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Saudi steam plants cycle more than they used to. Combined cycle units follow the grid, desalination cogeneration plants ramp with water demand, and petrochemical boilers see turnarounds and trips. Every cold start pushes a gate valve from ambient to main steam temperature in an hour or two, and every trip does the reverse. The part that suffers first is the thin layer of hard-facing on the seat and disc.</p><h2>Why hard-facing cracks</h2><p>Seat faces on high-temperature valves are overlaid with a cobalt-based alloy (Stellite 6 or 21) or an iron-based alternative so that the sealing surfaces resist galling and wear. The overlay has a different thermal expansion coefficient from the body material, especially on F91 and F22 chrome-moly steels. On fast temperature change, the overlay is pulled by the base metal and can crack; once cracked, steam cuts a channel through the crack and the valve passes.</p><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Cause</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">What the valve maker controls</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Dilution of the overlay</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Two or more layers, low-dilution welding (PTA), hardness checked on the finished face</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Residual stress</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Pre-heat, controlled interpass temperature and post-weld heat treatment matched to the base metal</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Overlay too thick or too thin</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Finished thickness held to the design range after machining</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Wrong alloy for the base metal</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Alloy selection qualified for F91/F92 service, where cobalt overlays need extra care</td></tr></tbody></table><p>What the plant controls is the start-up ramp and the warming of the valve body before the disc is moved. A valve that is opened against full differential while the body is still cold is being asked to do two hard things at once.</p><h2>Gate or globe?</h2><p>Parallel slide gate valves are the usual choice for main steam isolation because they seal on the downstream seat under line pressure and tolerate thermal movement; flexible wedge gates are used on feed water and smaller steam lines. Globe valves handle drains, vents, bypass and warming lines, where throttling and tight shut-off on small flows matter. Okano supplies all three in forged and cast construction from Class 600 to 4500, along with the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/main-steam-isolation-valves-saudi-arabia">main steam isolation valves</a> covered in the earlier article.</p><h2>Inspection and repair in the Kingdom</h2><p>When a high-temperature valve passes, the fix depends on what the inspection finds. Minor seat damage can be lapped in place; cracked hard-facing has to be machined out, re-welded with the qualified procedure and heat treated, which is factory or specialist work. The BTGC service center in Jubail inspects, laps and pressure tests power plant valves and coordinates factory re-facing with Okano when it is needed. Keeping a spare disc and seat ring set on site for the main steam valves turns a two-month repair into a two-day one.</p><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/main-steam-line-gate-valves-power-plant-saudi-arabia.webp" alt="Main steam line gate valves installed in a power plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Okano Valve from BTGC</h2><p>Okano Valve Mfg. Co., Ltd., Kitakyushu, has made high-temperature and high-pressure valves for Japanese utilities since 1926 and supplies thermal and nuclear plants worldwide. BTGC is the <a href="https://www.btc-ksa.com/okano-valve-saudi-arabia">Okano Valve partner in Saudi Arabia</a>, supplying new valves and spares and supporting inspection and repair from Jubail. See the <a href="https://www.btc-ksa.com/flow-control-valves-solutions">flow control and valves</a> page and the <a href="https://www.btc-ksa.com/power-utilities">power and utilities sector page</a>.</p><h2>Questions buyers ask</h2><p><strong>Can an existing valve be re-faced locally?</strong> Lapping and seat machining yes; welding new hard-facing on F91 bodies needs the qualified procedure and heat treatment, which BTGC arranges with the factory.</p><p><strong>What documents should come with a new valve?</strong> Material certificates, hard-facing procedure qualification, PWHT charts, hydrostatic and seat test reports and the ASME B16.34 marking.</p><p><strong>Do you stock spares?</strong> Discs, seat rings, stems and packing for common sizes can be held in Jubail under a stock agreement with the plant.</p><h2>Contact the BTGC valve team</h2><p>Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Sun, 15 Nov 2026 08:29:14 +0300</pubDate></item></channel></rss>