<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/summer-performance/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #summer performance</title><description>BTGC - Knowledge Hub #summer performance</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/summer-performance</link><lastBuildDate>Wed, 18 Nov 2026 11:16:29 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Keeping Air-Cooled Heat Exchangers Effective in Saudi Summer]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/air-cooled-heat-exchanger-summer-performance-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/kelvion-industrial-air-cooler.webp"/>Why air coolers lose capacity in summer heat and dust, and how fin cleaning, fan checks, recirculation control and spray cooling restore it. Kelvion from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_EUkUrt7PRZqTXJ8ipakNYA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_Sq8IdYBDSZGUhL6KvesxFw" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_S653DFTVRpmaVyCSNLcbOg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_rMUp58yuugwjjxqZCWEEEQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> air-cooled heat exchangers reject heat to ambient air, so their capacity falls as the air gets hotter, exactly when Saudi plants need them most. Dust-clogged fins, slipping belts, wrong fan blade pitch and hot air recirculating from outlet to inlet make the summer shortfall worse. A pre-summer programme of fin cleaning, fan and drive checks and recirculation control, and in some cases spray or adiabatic pre-cooling, recovers much of the lost duty. BTGC supplies Kelvion air coolers and dry coolers and supports their maintenance.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/kelvion-industrial-air-cooler.webp" alt="Kelvion industrial air cooler on a steel structure" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>In refineries, gas plants, compressor stations and power plants across the Kingdom, air coolers replace water cooling where water is scarce. They are designed for a summer design air temperature, but over time their real performance drops below the design curve. The gap shows up as high process outlet temperatures, compressor discharge alarms and reduced throughput on the hottest afternoons.</p><h2>Why capacity falls</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Cause</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Effect</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Check</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Fouled fins (dust, sand, oil mist, insects)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Less airflow and heat transfer</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Inspect with a light behind the bundle; measure air-side pressure drop</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Fan problems: wrong blade pitch, worn belts, slipping drives, failed motors</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Lower airflow</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Measure motor current and airflow; check blade angle and belt tension</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Hot air recirculation</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Inlet air hotter than ambient</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Compare inlet temperature with ambient; review layout, wind and nearby equipment</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Internal fouling</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Lower heat transfer on the process side</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Trend process outlet temperature and pressure drop against design</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Louvres stuck closed, damaged plenums or seals</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Air bypasses the bundle or is restricted</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Inspect louvre linkages, plenum panels and seals</td></tr></tbody></table><h2>Pre-summer checklist</h2><ul><li><p>Clean fins with low-pressure water or air from the air-outlet side, against the airflow, without bending fins; avoid high-pressure jets that flatten them.</p></li><li><p>Set fan blades to the design pitch and check tip clearance to the fan ring.</p></li><li><p>Replace worn belts and check sheave alignment, or check gear drives and couplings.</p></li><li><p>Check fan motors, bearings and vibration switches, and repair any fan out of service before summer.</p></li><li><p>Free and adjust louvres and check the control system and variable-speed drives.</p></li><li><p>Repair plenum panels, seals and fan rings so air passes through the bundle, not around it.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/kelvion-rooftop-air-cooled-heat-exchanger-units.webp" alt="Rooftop air-cooled heat exchanger units with axial fans" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Recirculation and layout</h2><p>Hot exhaust air drawn back into the inlet raises the effective air temperature and can cost several degrees of approach. It is worst for forced-draught units, banks close to buildings or tall equipment, and banks in a crosswind. Wind walls, extended fan stacks or moving nearby obstructions can reduce it. On new projects, spacing and orientation are part of the design, as discussed in <a href="https://www.btc-ksa.com/Knowledge-Hub/post/api-661-air-cooled-heat-exchangers-saudi-arabia">API 661 air coolers</a>.</p><h2>Adding capacity in summer</h2><p>Where cleaning and fan work are not enough, inlet air can be pre-cooled by evaporation, using sprays or adiabatic pads, for a limited number of hot hours each year. Water quality must be controlled to avoid scaling the fins. For larger shortfalls, extra bays or a hybrid system may be needed; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/adiabatic-coolers-water-saving-saudi-arabia">adiabatic coolers</a> and <a href="https://www.btc-ksa.com/Knowledge-Hub/post/air-fin-coolers-air-cooled-heat-exchangers-saudi-arabia">air fin coolers</a>.</p><h2>Kelvion from BTGC</h2><p>Kelvion supplies air-cooled heat exchangers, dry coolers, plate heat exchangers and shell and tube exchangers for industry and utilities. BTGC is the <a href="https://www.btc-ksa.com/kelvion-saudi-arabia">Kelvion partner in Saudi Arabia</a> for new equipment, replacement bundles and spare parts. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/gasketed-plate-heat-exchanger-maintenance-saudi-arabia">plate heat exchanger maintenance</a> and the <a href="https://www.btc-ksa.com/process-separation">process and thermal</a> page.</p><h2>Questions buyers ask</h2><p><strong>How often should air cooler fins be cleaned?</strong> At least once before each summer, and more often in dusty areas or near sources of oil mist; inspection decides.</p><p><strong>Does fan blade pitch really make a difference?</strong> Yes. Blades set below the design angle move less air; resetting them to design, within the motor's power limit, can recover a noticeable part of the lost duty.</p><p><strong>Is spray cooling of fins safe?</strong> Only with treated water and a system designed for it; untreated water leaves scale on fins and reduces performance over time.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Mon, 16 Nov 2026 10:44:19 +0300</pubDate></item></channel></rss>