<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/thermometers/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #thermometers</title><description>BTGC - Knowledge Hub #thermometers</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/thermometers</link><lastBuildDate>Wed, 18 Nov 2026 04:42:29 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Bimetal and Gas-Filled Thermometers: Selection and Installation]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/bimetal-gas-filled-thermometers-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/nuova-fima-pressure-gauges-diaphragm-seals.webp"/>When to use bimetal or gas-filled dial thermometers, ranges, accuracy, capillaries, thermowells and installation tips for process plants. Nuova Fima, BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_46oPumwcQtGXZtQX3tzBBA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_JidODK1sSCWrZ6tfgIW-Fw" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_uG1i-tLuQnyd5vibnBv0Nw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_MXefUDQtnZXlNguAakqvbA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> dial thermometers give operators a local reading without power. Bimetal thermometers use a coiled strip of two metals that twists with temperature, and suit direct mounting on pipes and vessels. Gas-filled thermometers use a sealed bulb and capillary, so the dial can sit a few metres away, and they handle vibration and wider ranges well. Both normally sit in a thermowell. BTGC supplies Nuova Fima thermometers and thermowells.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/nuova-fima-pressure-gauges-diaphragm-seals.webp" alt="Nuova Fima gauges and instruments" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Pumps, exchangers, tanks and utility lines in Saudi plants all carry local temperature gauges for operator rounds.</p><h2>Bimetal or gas-filled</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Feature</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Bimetal</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Gas-filled</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Principle</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Twisting bimetal coil</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Gas pressure in a sealed bulb</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Remote mounting</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">No, dial on the stem</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Yes, through a capillary</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Vibration</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Liquid-filled cases help</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Generally good</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Response</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Slower</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Faster with a suitable bulb</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Typical use</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Pipes, tanks, utility lines</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Machines, panels, hard-to-read points</td></tr></tbody></table><h2>Selection points</h2><ul><li><p>Choose a range so normal operation sits in the middle of the scale.</p></li><li><p>Match stem or bulb length to the thermowell and insertion depth; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/thermowells-temperature-measurement-saudi-arabia">thermowells</a>.</p></li><li><p>Use stainless steel cases and suitable windows for outdoor and corrosive areas.</p></li><li><p>Choose every-angle or back-connected designs so dials face the operator.</p></li><li><p>Add liquid filling where vibration makes pointers hard to read; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/pressure-gauges-vibration-pulsation-diaphragm-seals-saudi-arabia">gauges under vibration</a>.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/process-piping-petrochemical-plant.webp" alt="Process piping with local instruments" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Installation and checks</h2><ul><li><p>Always fit in a thermowell on pressurised lines, so the instrument can be removed safely.</p></li><li><p>Protect capillaries from kinks and mechanical damage.</p></li><li><p>Keep direct sun off dials where possible; it can affect readings and windows.</p></li><li><p>Check thermometers against a reference during calibration rounds; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/pressure-gauge-transmitter-calibration-saudi-arabia">calibration</a>.</p></li></ul><h2>Nuova Fima from BTGC</h2><p>Nuova Fima makes pressure gauges, bimetal and gas-filled thermometers, thermowells, diaphragm seals and switches. BTGC supplies <a href="https://www.btc-ksa.com/Knowledge-Hub/post/nuova-fima-saudi-arabia">Nuova Fima in Saudi Arabia</a> for projects and maintenance contracts. See also the <a href="https://www.btc-ksa.com/petrochemicals">petrochemicals sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>How accurate are dial thermometers?</strong> Typically around 1% of span, depending on type and class; check the data sheet.</p><p><strong>Can a bimetal thermometer be used without a thermowell?</strong> Only on unpressurised or low-risk points; process lines need a thermowell.</p><p><strong>Does BTGC supply matched thermowells?</strong> Yes, thermowells sized to the thermometer and process.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 14:26:15 +0300</pubDate></item></channel></rss>