<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/vfd/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #VFD</title><description>BTGC - Knowledge Hub #VFD</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/vfd</link><lastBuildDate>Wed, 18 Nov 2026 04:38:16 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[VFD Harmonic Mitigation: Chokes, Filters and Active Front Ends]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/vfd-harmonic-mitigation-active-front-end-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/danfoss-vacon-ac-drives-range.webp"/>How to keep variable speed drive harmonics within limits: DC chokes, 12-pulse, passive filters, active filters and active front end drives, and IEEE 519. VACON.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_4HIIYYiGRq6ELncaz8hCVw" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_jrY5dBV7SiuQLv2FKNqyVw" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_uYRJUR9sR2mHUFfSL8BmaA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_ELGpsGE8OpYC2r_CzIewBg" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> a standard six-pulse drive draws current in pulses, adding harmonic currents that heat transformers and cables, disturb other equipment and can break utility limits. Mitigation ranges from simple DC chokes to 12- or 18-pulse transformers, passive and active filters, and active front end drives with near-sinusoidal input current. The right choice depends on how much of the load is on drives and the limits at the point of supply. BTGC supplies Danfoss VACON drives and options.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/danfoss-vacon-ac-drives-range.webp" alt="Danfoss VACON AC drives" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Water pumping stations, HVAC and district cooling plants, desalination and mining sites in the Kingdom often have most of their load on drives.</p><h2>Mitigation options</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Method</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Typical result</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Notes</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">DC or AC chokes</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Lower distortion than a bare drive</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Low cost; often built into drives</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">12- or 18-pulse</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Large reduction with phase-shifting transformers</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Suits large single drives</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Passive filters</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Tuned reduction of main harmonics</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Check for resonance and light-load behaviour</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Active filters</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Cancel harmonics for groups of drives</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Good for retrofits and mixed loads</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Active front end (AFE) drives</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Very low input distortion and regeneration</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Higher cost; ideal for large or regenerative loads</td></tr></tbody></table><h2>Planning the study</h2><ul><li><p>Check the share of drive load on each transformer and the short-circuit level at the point of common coupling.</p></li><li><p>Compare predicted distortion with IEEE 519 or the utility's grid code limits.</p></li><li><p>Watch for resonance with power factor capacitors, which can amplify harmonics.</p></li><li><p>Include standby generators, where harmonics are more severe.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/hd-hyundai-electric-transformer-gis.webp" alt="Plant substation feeding drive loads" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>In operation</h2><ul><li><p>Measure harmonics after commissioning and after adding drives.</p></li><li><p>Check transformer and cable temperatures in summer.</p></li><li><p>Keep filter capacitors and fans maintained.</p></li><li><p>For energy savings and heat derating, see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/vfd-pumps-fans-energy-savings-harmonics-saudi-arabia">VFDs for pumps and fans</a>.</p></li></ul><h2>Danfoss VACON from BTGC</h2><p>VACON drives, part of Danfoss Drives, include air- and liquid-cooled drives with low-harmonic and active front end options. BTGC supplies <a href="https://www.btc-ksa.com/Knowledge-Hub/post/danfoss-vacon-saudi-arabia">Danfoss VACON in Saudi Arabia</a> with options and spares. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/obsolete-drive-replacement-vfd-retrofit-saudi-arabia">drive retrofits</a> and the <a href="https://www.btc-ksa.com/electrical-power-systems-saudi-arabia">electrical and power systems</a> page.</p><h2>Questions buyers ask</h2><p><strong>Do small drives need filters?</strong> Usually not one by one, but many small drives together can exceed limits.</p><p><strong>What is an active front end?</strong> A drive input stage using switching transistors instead of diodes, giving low harmonics and the ability to regenerate.</p><p><strong>Can harmonics damage transformers?</strong> They add heating, so heavily loaded transformers may need derating or a K-rated design.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 18 Nov 2026 14:24:36 +0300</pubDate></item><item><title><![CDATA[VFDs for Pumps and Fans: Energy Savings, Harmonics and Heat Derating]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/vfd-pumps-fans-energy-savings-harmonics-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/danfoss-vacon-ac-drives-range.webp"/>How variable frequency drives cut pump and fan energy, how to meet IEEE 519 harmonic limits, and how to size drives for Saudi heat. Danfoss VACON drives, BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_BqY-m47JTBaVZYK73dE0bg" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_AYRZSCgLQS-EukGVQl9zsA" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_LzS5CV2ORiGYLi5yLWqYGg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_TNAVaBIlQofgNJ1QYmkHAQ" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> for centrifugal pumps and fans, flow varies with speed, but power varies roughly with the cube of speed. Running at 80 percent speed instead of throttling can cut power by around half. That is why variable frequency drives (VFDs) pay back quickly on variable-flow pumps, cooling tower fans and air handling units. Drives also bring issues to manage: harmonic currents on the supply, motor insulation stress, and derating in high ambient temperatures. BTGC supplies Danfoss VACON low and medium voltage drives.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/danfoss-vacon-ac-drives-range.webp" alt="Danfoss VACON AC drives range" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Water transmission and distribution, district cooling, desalination, HVAC and process cooling are major energy users in the Kingdom. Saudi energy efficiency programmes and rising tariffs make speed control on these loads one of the clearest efficiency upgrades.</p><h2>Where the savings come from</h2><ul><li><p>Affinity laws: flow is proportional to speed, head to speed squared and power to speed cubed.</p></li><li><p>Throttling a valve or damper wastes the extra head; reducing speed removes it.</p></li><li><p>Savings are largest where the load varies widely and runs long hours; systems with high static head save less.</p></li><li><p>Soft starting reduces mechanical stress and inrush current, extending pump and motor life.</p></li></ul><h2>Harmonics and power quality</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Solution</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Typical result</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">6-pulse drive with DC or AC choke</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Basic reduction; current distortion often 30 to 45 percent</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Passive harmonic filter</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Current distortion reduced to around 5 to 10 percent</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Active front end (low harmonic drive)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Current distortion below about 5 percent; can also regenerate</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">12- or 18-pulse with phase-shifting transformer</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Common on medium voltage and large low voltage drives</td></tr></tbody></table><p>IEEE 519 sets harmonic limits at the point of common coupling, and utilities in the Kingdom may set their own requirements. A harmonic study during design avoids overheating of transformers and cables, nuisance trips and interference with other equipment.</p><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/desalination-plant-saudi-arabia.webp" alt="Desalination plant pumping station" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Installing drives in hot climates</h2><ul><li><p>Most drives are rated for 40 to 50 &deg;C; above that they must be derated or oversized, so specify the real room temperature.</p></li><li><p>Cool electrical rooms properly; heat from drives can be large at full load.</p></li><li><p>Use IP-rated enclosures and filters against dust; keep heat sinks clean.</p></li><li><p>Use motors suitable for inverter duty, and dV/dt or sine filters for long cables to protect insulation and bearings.</p></li><li><p>Check bearing currents on larger motors; insulated bearings or shaft grounding may be needed.</p></li></ul><h2>Danfoss VACON from BTGC</h2><p>Danfoss Drives supplies VACON and VLT low and medium voltage AC drives for pumps, fans, compressors and process machines. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/danfoss-vacon-saudi-arabia">Danfoss VACON partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/soft-starting-heavy-duty-motors-weg-mv-soft-starters-vs-vfds-saudi-arabia">MV soft starters or VFDs</a>, the <a href="https://www.btc-ksa.com/electrical-power-systems-saudi-arabia">electrical power systems</a> page and the <a href="https://www.btc-ksa.com/power-utilities">power and utilities sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Does a VFD always save energy?</strong> Only where the load varies. A pump running at constant full flow gains little and the drive adds small losses.</p><p><strong>Can an existing motor run on a VFD?</strong> Often yes, after checking insulation, cooling at low speed and bearing currents.</p><p><strong>Can BTGC do a savings estimate?</strong> Yes, from the duty profile, pump curves and running hours.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 10:28:32 +0300</pubDate></item><item><title><![CDATA[Bearing Currents in VFD-Driven Motors: Causes and Cures]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/vfd-bearing-currents-mv-motors-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/weg-high-voltage-motor-w60.webp"/>Why motors on variable frequency drives suffer bearing fluting, and how insulated bearings, shaft grounding and cabling prevent it. WEG MV motors from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_xn73p17mTBSQqsMvkZawEA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_-Zs6XTK8RZS1B3sbQ5Zsjw" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_hge1fO5HSeGOxQ6oWjWC3Q" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_FyDTQb1Tm_3w-5n7upoA2Q" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> variable frequency drives save energy and soften starts, but the fast switching of the inverter puts a common-mode voltage on the motor that can discharge through the bearings. The result is electrical erosion: frosted races, washboard fluting, noisy bearings and early failure, sometimes within months. The cure is a system design that gives the current a better path: insulated bearings, shaft grounding, symmetrical shielded cable and proper bonding. BTGC supplies WEG medium and high voltage motors and drives configured for VFD duty and repairs damaged motors at its WEG approved service center in Jubail.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/weg-high-voltage-motor-w60.webp" alt="WEG industrial electric motor" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>A typical story: a pump or fan motor is converted from direct-on-line starting to a VFD to save energy. A year later the bearings are noisy, vibration analysis shows bearing defect frequencies, and the removed bearing has a grey, frosted race with evenly spaced ridges like a washboard. The grease is dark. The bearing did not fail from load or lubrication; it was machined by millions of tiny electrical discharges.</p><h2>Where the current comes from</h2><p>A PWM inverter switches very fast, and the sum of the three phase voltages at the motor is no longer zero as it is on a sine-wave supply. This common-mode voltage couples through the motor's internal capacitances onto the rotor and shaft. When the voltage across the bearing's oil film exceeds its breakdown level, it discharges through the rolling elements. IEC TS 60034-25 describes the mechanisms and the measures that limit them.</p><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Type of bearing current</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Typical motors</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Mechanism</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Capacitive discharge (EDM)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Small and medium motors</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Shaft voltage builds up and discharges through the oil film in short sparks</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Circulating high-frequency current</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Larger motors, roughly 100 kW and above</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Common-mode current in the stator induces a voltage along the shaft, driving current through one bearing, the frame and the other bearing</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Rotor ground current</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Installations with poor frame earthing or bonding</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Current finds its way to earth through the bearings and the driven machine, often damaging pump or gearbox bearings too</td></tr></tbody></table><h2>Signs of electrical bearing damage</h2><ul><li><p>Frosted or matt grey raceways, often with fluting: evenly spaced ridges across the race.</p></li><li><p>Micro-craters visible under magnification on balls or rollers.</p></li><li><p>Grease darkened by metal particles and burnt oil.</p></li><li><p>Rising high-frequency vibration and noise at bearing defect frequencies.</p></li><li><p>Damage in the driven equipment's bearings as well as the motor's.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/electric-motor-stator-rewind-btgc-jubail-workshop.webp" alt="Large electric motor stator in the BTGC motor workshop in Jubail" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>How to prevent it</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Measure</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">What it does</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Insulated bearing (usually non-drive end) or ceramic rolling elements</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Breaks the circulating current loop through the bearings</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Shaft grounding brush or ring at the drive end</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Gives shaft voltage a low-impedance path to the frame instead of through the bearing</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Symmetrical shielded motor cable with 360-degree gland termination</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Returns common-mode current to the drive along the shield, not through the motor and driven machine</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">High-frequency bonding between motor frame, driven machine and drive</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Keeps frame and driven machine at the same potential</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Insulated coupling</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Stops current passing into the driven machine's bearings</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Common-mode or output filters at the drive</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Reduce the common-mode voltage and the rate of voltage rise at the source</td></tr></tbody></table><p>No single item works on every installation. Large MV motors on drives usually combine an insulated non-drive end bearing with a shaft grounding device and correct cabling, and the winding insulation must also be rated for the voltage stresses of inverter duty, as covered in <a href="https://www.btc-ksa.com/Knowledge-Hub/post/preventing-stator-winding-failure-duraguard-vpi-insulation-saudi-arabia">preventing stator winding failure</a>.</p><h2>When retrofitting a VFD to an existing motor</h2><ul><li><p>Check with the motor maker that the insulation system suits inverter duty.</p></li><li><p>Fit an insulated non-drive end bearing at the next overhaul, and a shaft grounding device at the drive end.</p></li><li><p>Review the cable type and the earthing and bonding scheme, not just the motor.</p></li><li><p>Measure shaft voltage after commissioning and trend bearing vibration in the first months.</p></li></ul><h2>WEG motors and drives from BTGC</h2><p>BTGC is the <a href="https://www.btc-ksa.com/weg">WEG partner in Saudi Arabia</a> for medium and high voltage motors and MV drives, and new WEG motors for VFD duty can be specified with insulated bearings and shaft grounding. The <a href="https://www.btc-ksa.com/btgc-jubail-service-center">BTGC service center in Jubail</a>, a WEG approved service center, inspects and repairs motors with electrical bearing damage and fits insulated bearings during overhaul. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/converting-mv-soft-starters-weg-mvw3000-vfd-saudi-arabia">converting MV soft starters to VFDs</a> and <a href="https://www.btc-ksa.com/Knowledge-Hub/post/hv-motor-rewind-or-replace-saudi-arabia">rewind or replace decisions</a>.</p><h2>Questions buyers ask</h2><p><strong>Do all motors on VFDs need insulated bearings?</strong> Not all. Smaller motors may only need correct cabling and bonding; larger motors on drives usually need an insulated bearing and a shaft grounding device. BTGC reviews the installation.</p><p><strong>Can fluting be repaired?</strong> The damaged bearing must be replaced, and the cause must be fixed, or the new bearing will fail the same way.</p><p><strong>Can shaft voltage be measured on site?</strong> Yes, with an oscilloscope and a shaft voltage probe while the motor runs on the drive; the result shows which measures are needed.</p><h2>Contact the BTGC power division</h2><p>Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Mon, 16 Nov 2026 09:54:31 +0300</pubDate></item></channel></rss>