<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/water-saving/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #water saving</title><description>BTGC - Knowledge Hub #water saving</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/water-saving</link><lastBuildDate>Wed, 18 Nov 2026 11:16:29 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Adiabatic Coolers That Save Water in Saudi Arabia]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/adiabatic-coolers-water-saving-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/bac-cooling-towers-rooftop-installation.webp"/>Adiabatic coolers cut water use by 60 to 90 percent against cooling towers while reaching temperatures dry coolers cannot. BAC adiabatic coolers from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_56fz82cwRb6rlYcRYDAAcA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_nqtHTvCARMSUrs-8gIu94A" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_uf0UFvp4ROOReyefgH_avA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_NUBL73nbuhp5TrAJIaGNig" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> an adiabatic cooler runs dry for most of the year and wets its air inlet only on the hottest days, so it uses a fraction of the water of a cooling tower while reaching temperatures a dry cooler cannot. For Saudi plants paying for make-up water and water treatment, it is often the best balance of water, power and footprint. BTGC supplies Baltimore Aircoil (BAC) adiabatic, hybrid and closed-circuit coolers in Saudi Arabia.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/bac-cooling-towers-rooftop-installation.webp" alt="BAC cooling towers installed on a plant roof" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>A conventional open cooling tower evaporates about 1.8 litres of water for every kilowatt-hour of heat it rejects, and bleeds off more to control dissolved solids. For a 10 MW cooling load that is tens of thousands of cubic metres a year, bought from the industrial-city utility, treated with chemicals and sent to drain. A dry cooler uses no water but cannot cool below the air temperature plus an approach, which on a 46 &deg;C day is not useful for most processes. The adiabatic cooler sits between the two.</p><h2>How it works</h2><p>An adiabatic cooler is a dry, finned-coil cooler with an evaporative pre-cooling stage on the air inlet. Below a set air temperature the pads or spray stay off and the unit runs as a dry cooler. When the air temperature rises, water wets the inlet pads; the air cools by evaporation before it reaches the coil, and the coil sees air close to the wet-bulb temperature rather than the dry-bulb. In Dammam in July that difference is 15 to 20 &deg;C.</p><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Cooler type</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Water use</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Lowest fluid temperature</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Footprint</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Open cooling tower</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">High, continuous</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Wet-bulb + 3 to 5 &deg;C</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Small</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Closed-circuit cooling tower</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">High, continuous</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Wet-bulb + 4 to 6 &deg;C</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Small</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Adiabatic cooler</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Low, only in hot hours; 60 to 90 per cent less than a tower</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Wet-bulb + 8 to 12 &deg;C in adiabatic mode</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Medium</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Dry cooler</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">None</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Dry-bulb + 5 to 10 &deg;C</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Large</td></tr></tbody></table><h2>Where adiabatic cooling fits in Saudi plants</h2><ul><li><p><strong>Compressor and chiller condensers</strong> in factories and data centres where water supply is metered and limited.</p></li><li><p><strong>Closed-loop cooling for furnaces, presses and injection moulding</strong> in the industrial cities.</p></li><li><p><strong>Process cooling at inland sites</strong> without a seawater or treated effluent supply.</p></li><li><p><strong>Replacement of ageing open towers</strong> where the owner wants to stop water treatment and legionella management on open water.</p></li></ul><h2>Water quality and hygiene</h2><p>Because the water in an adiabatic cooler only wets the pads and drains away, there is no recirculating open basin, so the legionella risk and the chemical treatment load are far lower than on a tower. BAC's designs use pads that dry completely between cycles and controls that flush the water system, which simplifies compliance with the operator's water safety plan. Make-up water can be the utility supply; softening is advised where the water is hard, to keep the pads clean.</p><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/bac-closed-circuit-cooling-tower.webp" alt="BAC closed-circuit cooling tower" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Baltimore Aircoil from BTGC</h2><p>Baltimore Aircoil Company builds adiabatic coolers and condensers (TrilliumSeries and Nexus ranges), closed-circuit coolers, open cooling towers and evaporative condensers in the USA and Belgium. BTGC is the <a href="https://www.btc-ksa.com/baltimore-aircoil-saudi-arabia">BAC partner in Saudi Arabia</a>, from selection and supply to spare parts and refurbishment. The earlier article covers <a href="https://www.btc-ksa.com/Knowledge-Hub/post/closed-circuit-cooling-towers-saudi-arabia">closed-circuit cooling towers for process water</a>; see also the <a href="https://www.btc-ksa.com/process-separation">process and thermal</a> page and the <a href="https://www.btc-ksa.com/petrochemicals">petrochemicals sector page</a>.</p><h2>Questions buyers ask</h2><p><strong>How many hours a year does the adiabatic mode run?</strong> In the Eastern Province typically 1,500 to 2,500 hours, depending on the set point; the rest of the year the unit is dry.</p><p><strong>Can an adiabatic cooler replace a tower one for one?</strong> Usually with a larger footprint and a slightly higher design fluid temperature; BTGC runs the selection with BAC's software on the site weather data.</p><p><strong>What maintenance does it need?</strong> Pad inspection and replacement every few years, coil cleaning and fan and control checks; no basin cleaning or biocide dosing.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Sun, 15 Nov 2026 08:35:03 +0300</pubDate></item><item><title><![CDATA[Air Fin Coolers Where Water Is Scarce: Saudi Design Points]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/air-fin-coolers-air-cooled-heat-exchangers-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/kelvion-rooftop-air-cooled-heat-exchanger-units.webp"/>Designing air-cooled heat exchangers for 50 degree air, dust and recirculation, and when hybrids make sense. Kelvion air fin coolers to API 661 from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_YOsPI3EFSLC8sBY67JXeVQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_Lq2JlPBQQx69snQXQoz91Q" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_I5ZHIvjBQvCcaPSiPhN9AA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_elen6uMzHOfTVLkLaqurEw" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> an air fin cooler rejects process heat to the air instead of to water, so it needs no cooling water, no water treatment and no blowdown. The price is a larger footprint and a design that must work at a 50 &deg;C summer air temperature. BTGC supplies Kelvion air-cooled heat exchangers to API 661 for Saudi refineries, gas plants and petrochemical units, and supports bundles, fans and spares locally.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/kelvion-rooftop-air-cooled-heat-exchanger-units.webp" alt="Rooftop air-cooled heat exchanger units with axial fans" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Water is the scarcest utility in the Kingdom. Coastal plants have seawater, but inland gas plants, pipeline compressor stations, mining sites and the new industrial zones away from the coast do not, and even coastal plants pay for every cubic metre of make-up water a cooling tower evaporates. The air fin cooler is how a process plant rejects heat without water, and it is the standard choice for overhead condensers, compressor intercoolers, lube oil coolers and product rundown coolers across Saudi oil and gas.</p><h2>How an air-cooled heat exchanger works</h2><p>The process fluid flows inside finned tubes arranged in bundles; axial fans push (forced draft) or pull (induced draft) ambient air across the fins. The fins multiply the air-side surface area by ten to twenty times, which compensates for air being a far poorer coolant than water. The unit is sized for the design air temperature, and that is where Saudi projects differ from most of the world.</p><h2>Design points for the Gulf</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Issue</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Design response</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Design air temperature of 46 to 50 &deg;C</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Larger surface, more bays; process outlet temperatures above 60 &deg;C are realistic, lower ones need trim cooling</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Hot air recirculation</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Induced draft with tall stacks, bay spacing and plot layout studied by CFD on large installations</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Dust and sand</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Wider fin pitch, embedded or extruded fins that resist cleaning damage, access for washing</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Winter performance</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Variable speed or auto-variable pitch fans, louvres where pour point or hydrate formation matters</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Corrosive atmosphere</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Aluminium fins with galvanised or coated tubes; stainless or duplex tubes where the process demands</td></tr></tbody></table><h2>Fin types and when they matter</h2><p>API 661 recognises several fin constructions: L-footed and overlapped L fins for temperatures to about 130 &deg;C, embedded (G) fins to 400 &deg;C and beyond, and extruded fins that give the best corrosion protection and mechanical strength. Saudi plants with sand cleaning and high tube-wall temperatures tend toward embedded or extruded fins; the slightly higher cost is paid back in fin life.</p><h2>Water-saving hybrids</h2><p>Where an air cooler cannot reach the required outlet temperature on the hottest days, two options avoid a full wet cooling system: a small trim cooler on cooling water for the last few degrees, or an adiabatic pre-cooling pad that wets the inlet air only during peak hours. Kelvion offers both approaches within its air cooler and dry cooler ranges, and the same thinking is applied to utility cooling by <a href="https://www.btc-ksa.com/baltimore-aircoil-saudi-arabia">Baltimore Aircoil</a> adiabatic coolers.</p><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/hemaco-shell-and-tube-heat-exchanger-tube-bundle.webp" alt="Shell and tube heat exchanger tube bundle" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Kelvion from BTGC</h2><p>Kelvion Holding GmbH, Germany, formerly GEA Heat Exchangers, designs and manufactures air-cooled heat exchangers to API 661 and ISO 13706, dry coolers, plate heat exchangers and shell and tube units. BTGC is the <a href="https://www.btc-ksa.com/kelvion-saudi-arabia">Kelvion partner in Saudi Arabia</a> for new units, replacement bundles, fans, drives and spares, with site support from Dammam, Jubail and Yanbu. See the earlier article on <a href="https://www.btc-ksa.com/Knowledge-Hub/post/plate-vs-shell-and-tube-heat-exchanger-saudi-arabia">choosing between plate and shell and tube exchangers</a>, the <a href="https://www.btc-ksa.com/process-separation">process and thermal</a> page and the <a href="https://www.btc-ksa.com/oil-gas">oil and gas sector page</a>.</p><h2>Questions buyers ask</h2><p><strong>What information does a quotation need?</strong> Process fluid, flow, inlet and outlet temperatures, allowable pressure drop, design pressure and temperature, site design air temperature and the plot space available.</p><p><strong>Can an existing air cooler be uprated?</strong> Often yes: new bundles with better fins, larger or variable speed fans and adiabatic pads can add 10 to 25 per cent capacity.</p><p><strong>Do you supply replacement bundles for other makers' units?</strong> Yes, built to the original data sheet and API 661.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Sun, 15 Nov 2026 08:33:27 +0300</pubDate></item></channel></rss>