<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.btc-ksa.com/Knowledge-Hub/tag/water-treatment/feed" rel="self" type="application/rss+xml"/><title>BTGC - Knowledge Hub #water treatment</title><description>BTGC - Knowledge Hub #water treatment</description><link>https://www.btc-ksa.com/Knowledge-Hub/tag/water-treatment</link><lastBuildDate>Wed, 18 Nov 2026 10:57:17 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Diaphragm Valves for Demineralised Water Plants in Power and Industry]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/diaphragm-valves-demineralisation-plants-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/saunders-diaphragm-valves-range.webp"/>Why demineralisation plants use lined diaphragm valves for acid, caustic and resin service, and how to keep regeneration reliable. Saunders from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_IkqTkCxgR1iDudDxJv5LtQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_m0ZkG6CCQoqDf3cBJfeZxQ" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_Gjz6aOGNRs6zmhUP6EPMlw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_9r5vwER11TtHTxyeXxh2Lw" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> power plants, petrochemical complexes and fertiliser plants need very pure, demineralised water for boilers and processes. Ion exchange units and polishing systems switch between service and regeneration, using hydrochloric or sulphuric acid and caustic soda. The many automatic valves in these units must handle corrosive chemicals and resin beads, operate thousands of times and never leak into the pure water. Lined diaphragm valves with suitable diaphragms are the standard choice. BTGC supplies Saunders industrial diaphragm valves.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/saunders-diaphragm-valves-range.webp" alt="Saunders diaphragm valves" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Boiler feedwater quality in Saudi power and industrial plants depends on reliable demineralisation, often starting from desalinated water. Valve leaks in regeneration lines can contaminate treated water or waste chemicals.</p><h2>Valve duties in a demin plant</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Duty</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Requirement</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Service inlet and outlet</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Tight shutoff to protect treated water quality</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Acid and caustic regeneration</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Corrosion resistance and chemical-compatible diaphragms</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Backwash and rinse</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Handle resin fines without damage</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Frequent cycling</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Reliable automatic operation over many cycles</td></tr></tbody></table><h2>Selection points</h2><ul><li><p>Rubber or fluoropolymer-lined bodies suited to each chemical; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/chemical-dosing-valves-desalination-water-treatment-saudi-arabia">chemical dosing valves</a>.</p></li><li><p>Diaphragm materials matched to acid, caustic and temperature.</p></li><li><p>Pneumatic actuators with position feedback for automatic sequences.</p></li><li><p>Resin traps or strainers to keep resin out of valves.</p></li><li><p>Consistent valve types across the plant to simplify spares.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/desalination-plant-saudi-arabia.webp" alt="Water treatment plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Maintenance tips</h2><ul><li><p>Replace diaphragms on a schedule based on cycles and chemical exposure.</p></li><li><p>Check actuator air supply and limit switch signals during regeneration.</p></li><li><p>Inspect linings for damage when valves are removed.</p></li><li><p>Track water quality after regeneration to detect leaking valves.</p></li><li><p>Keep spare diaphragms and actuator kits on site.</p></li></ul><h2>Saunders from BTGC</h2><p>Saunders, part of Crane ChemPharma and Energy, makes industrial and hygienic diaphragm valves. BTGC is the <a href="https://www.btc-ksa.com/saunders-saudi-arabia">Saunders partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/hygienic-diaphragm-valves-pharma-food-saudi-arabia">hygienic diaphragm valves</a> and the <a href="https://www.btc-ksa.com/power-utilities">power and utilities sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Why diaphragm valves in demin plants?</strong> They isolate chemicals from the valve mechanism, resist corrosion with linings and suit automatic cycling.</p><p><strong>How often should diaphragms be changed?</strong> Based on cycle counts and inspection; many plants change them at planned intervals.</p><p><strong>Does BTGC supply actuated diaphragm valves?</strong> Yes, with pneumatic actuators and position feedback.</p><h2>Contact the BTGC valve team</h2><p>Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 16:18:41 +0300</pubDate></item><item><title><![CDATA[Gearmotors for Water and Wastewater Treatment: Clarifiers, Mixers and Screens]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/gearmotors-water-wastewater-treatment-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/sumitomo-cyclo-gearmotors.webp"/>How to choose gearmotors for clarifiers, mixers, screens and aerators in water and wastewater plants, and how to protect them. Sumitomo Cyclo, BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_9w8j24k-QEyec0uNgTrsFw" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_6L0S3VYFT0Ob1Dyok90PyQ" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_wagGQsp8S0-Rt1KBX7ltTw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_uV76LBx8_B6ZQzruTX6LkA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> water and wastewater plants are full of slow-turning machines: clarifier and thickener drives, mixers, flocculators, screens, scrapers and aerators. They run continuously outdoors, often in humid, corrosive air, and some see sudden overloads from debris or sludge. Gearmotors and reducers chosen for high reduction ratios, shock loads and corrosion protection keep these machines running with little attention. BTGC supplies Sumitomo Cyclo gearmotors and gear units.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/sumitomo-cyclo-gearmotors.webp" alt="Sumitomo Cyclo gearmotors" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>The Kingdom is building and upgrading many water treatment, sewage treatment and reuse plants. Small drive failures can stop a clarifier or screen and quickly affect treatment quality.</p><h2>Typical drives and needs</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Machine</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Drive needs</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Clarifier and thickener drives</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Very high reduction, high output torque, overload protection</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Flocculators and mixers</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Continuous duty, speed adjustment, overhung loads</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Bar screens and rakes</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Frequent starts and stops, shock loads from debris</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Surface aerators</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">High torque, thrust and overhung loads</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Belt and chain scrapers</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Low speed, long running hours</td></tr></tbody></table><h2>Selection points</h2><ul><li><p>Service factor based on 24-hour duty and shock loads.</p></li><li><p>Corrosion protection: suitable paint systems, stainless fasteners and sealed designs for humid, H2S-laden air.</p></li><li><p>Torque limiters or overload protection on screens and clarifiers.</p></li><li><p>Lubrication suited to outdoor temperatures and long intervals.</p></li><li><p>Inverter-duty motors where speed is controlled by drives.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/desalination-plant-saudi-arabia.webp" alt="Water treatment plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Maintenance tips</h2><ul><li><p>Check oil or grease levels and seals on a regular round.</p></li><li><p>Watch for unusual noise, heat or vibration on clarifier drives.</p></li><li><p>Inspect torque limiter settings and overload alarms.</p></li><li><p>Keep breathers clean and prevent water entry in wash-down areas.</p></li><li><p>Hold spare gearmotors for critical screens and clarifiers.</p></li></ul><h2>Sumitomo from BTGC</h2><p>Sumitomo Drive Technologies makes Cyclo reducers, gearmotors and industrial gear units, and owns Hansen Industrial Transmissions. BTGC is the <a href="https://www.btc-ksa.com/Knowledge-Hub/post/sumitomo-drive-saudi-arabia">Sumitomo partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/cycloidal-reducers-shock-loads-saudi-arabia">cycloidal reducers</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/aeration-blowers-wastewater-treatment-saudi-arabia">aeration blowers</a> and the <a href="https://www.btc-ksa.com/power-utilities">power and utilities sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Why use cycloidal reducers on screens?</strong> They handle shock loads from debris well and give high ratios in compact units.</p><p><strong>How do I protect clarifier drives from overload?</strong> With torque limiters, overload alarms and correct drive sizing.</p><p><strong>Does BTGC supply corrosion-protected units?</strong> Yes, with suitable paint systems and stainless options.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 14:19:04 +0300</pubDate></item><item><title><![CDATA[Valves for Chemical Dosing in Desalination and Water Treatment]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/chemical-dosing-valves-desalination-water-treatment-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/saunders-diaphragm-valves-range.webp"/>Valves for chemical dosing in desalination and water treatment: hypochlorite, acid, coagulant and antiscalant, and how to keep them leak-free. Saunders, BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_E5jR0E4rTLS3gXWl85vVhQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_dG5JSDEjRCqsb5jV3JlXQw" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_isnNHoGeSzmw2TWK1DvPyQ" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_hUXTGxE19QwLik2sayrlYA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> desalination and water treatment plants dose many chemicals: sodium hypochlorite for disinfection, sulphuric acid for pH control, ferric chloride as coagulant, antiscalants, sodium bisulphite and caustic soda. These chemicals are corrosive and some crystallise or release gas, so dosing lines need valves that resist them and do not leak. Lined and plastic diaphragm valves are a common choice because the diaphragm isolates the fluid from the mechanism. BTGC supplies Saunders industrial diaphragm valves.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/saunders-diaphragm-valves-range.webp" alt="Saunders diaphragm valves" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>The Kingdom operates some of the world's largest desalination plants and a growing number of water and wastewater treatment plants. Chemical dosing systems run continuously, and leaks cause corrosion, safety hazards and dosing errors.</p><h2>Chemicals and valve considerations</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Chemical</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Watch out for</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Sodium hypochlorite</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Corrodes most metals; releases gas that can lock lines; avoid trapped volumes</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Sulphuric acid</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Concentration and dilution effects; lined or suitable plastic valves</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Ferric chloride</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Highly corrosive to metals; lined or plastic valves</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Caustic soda</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Crystallises when cold; needs compatible elastomers</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Antiscalants and bisulphite</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Generally milder but check elastomer compatibility</td></tr></tbody></table><h2>Valve choices</h2><ul><li><p>Rubber or fluoropolymer-lined diaphragm valves for isolation on dosing and storage lines.</p></li><li><p>Plastic-bodied valves in compatible materials for small-bore dosing lines.</p></li><li><p>Diaphragm materials matched to each chemical and temperature, using maker compatibility tables.</p></li><li><p>Venting arrangements on hypochlorite lines to release gas.</p></li><li><p>Clear labelling and colour coding to prevent wrong connections.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/desalination-plant-saudi-arabia.webp" alt="Desalination plant" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Maintenance tips</h2><ul><li><p>Replace diaphragms on a schedule set by chemical and cycles, before they fail.</p></li><li><p>Check for crystallisation at valve seats on caustic and some acid lines.</p></li><li><p>Flush lines before maintenance and use proper protective equipment.</p></li><li><p>Keep spare diaphragms and bonnets for the most aggressive services.</p></li><li><p>Record leaks and failures to improve material choices.</p></li></ul><h2>Saunders from BTGC</h2><p>Saunders, part of Crane ChemPharma and Energy, makes industrial and hygienic diaphragm valves. BTGC is the <a href="https://www.btc-ksa.com/saunders-saudi-arabia">Saunders partner in Saudi Arabia</a>. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/hygienic-diaphragm-valves-pharma-food-saudi-arabia">hygienic diaphragm valves</a>, <a href="https://www.btc-ksa.com/Knowledge-Hub/post/seawater-butterfly-valves-desalination-saudi-arabia">seawater butterfly valves</a> and the <a href="https://www.btc-ksa.com/power-utilities">power and utilities sector</a> page.</p><h2>Questions buyers ask</h2><p><strong>Why use diaphragm valves on dosing lines?</strong> The diaphragm keeps the chemical away from the stem and bonnet, and lined bodies resist corrosion.</p><p><strong>Which diaphragm suits hypochlorite?</strong> Choose from the maker's compatibility data for concentration and temperature; PTFE-faced diaphragms are often used.</p><p><strong>Does BTGC stock diaphragms?</strong> Yes, common sizes and materials for Saunders valves.</p><h2>Contact the BTGC valve team</h2><p>Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 17 Nov 2026 14:05:40 +0300</pubDate></item><item><title><![CDATA[Cooling Tower Water: Cycles of Concentration, Scale and Water Savings]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/cooling-tower-water-cycles-concentration-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/bac-cooling-towers-rooftop-installation.webp"/>How evaporation, blowdown and cycles of concentration set cooling tower water use, and how to save water without scale or corrosion. BAC towers from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_ADz792w2RFmwBReHRP34Xw" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_lC_uJFJlQ_iACmNGCmcuhw" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_YtN5un_nRASJXFl-E_MZAg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_0jNarqW_a9XOsvizNPUR1g" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> a cooling tower cools water by evaporating part of it, and the dissolved salts left behind concentrate in the circulating water. Blowdown removes concentrated water to keep salts below scaling and corrosion limits, and make-up replaces both. Cycles of concentration describe that balance, and raising them safely is the main way to cut cooling tower water use. In the Kingdom, where water is costly and make-up may be desalinated, treated effluent or high in minerals, getting the balance right matters. BTGC supplies Baltimore Aircoil cooling towers and parts.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/bac-cooling-towers-rooftop-installation.webp" alt="Cooling towers installed on a process plant roof" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>A cooling tower evaporates roughly 1 per cent of the circulating flow for every 5.5 to 6 &deg;C of cooling range. At large plants that adds up to thousands of cubic metres a day, plus blowdown. Water treatment and tower operation decide how much extra water is lost to blowdown and whether the system stays free of scale and corrosion.</p><h2>The water balance</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Term</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Meaning</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Evaporation (E)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Water lost as vapour; carries the heat away and leaves salts behind</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Blowdown (B)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Water deliberately drained to limit salt concentration</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Drift (D)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Droplets carried out with the air; small with good drift eliminators</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Make-up (M)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Water added to replace evaporation, blowdown and drift: M = E + B + D</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Cycles of concentration (COC)</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Ratio of dissolved solids in the circulating water to those in the make-up; blowdown is roughly E / (COC - 1)</td></tr></tbody></table><h2>Why cycles matter</h2><p>Raising cycles from 2 to 5 cuts blowdown by about three quarters for the same evaporation, because blowdown is roughly evaporation divided by cycles minus one. The limit is set by the chemistry: calcium, silica, sulphate and chloride levels, alkalinity and pH. Above the safe limit, scale forms on fill and in exchangers, or corrosion accelerates. Good treatment programmes raise the safe cycles with scale and corrosion inhibitors and control them with conductivity-based automatic blowdown.</p><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/bac-closed-circuit-cooling-tower.webp" alt="BAC closed-circuit cooling tower" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Make-up water in Saudi Arabia</h2><ul><li><p><strong>Desalinated water</strong> is low in hardness, allowing high cycles, but it can be aggressive to metals and needs corrosion control.</p></li><li><p><strong>Groundwater</strong> is often high in hardness, silica and sulphate, which limits cycles; softening or side-stream treatment can help.</p></li><li><p><strong>Treated sewage effluent</strong> is increasingly used for cooling and needs attention to nutrients, biological growth and ammonia.</p></li><li><p><strong>Seawater</strong> towers use special materials and run at low cycles.</p></li></ul><h2>Operating practices</h2><ul><li><p>Control blowdown automatically on conductivity, not on fixed timers or manual valves.</p></li><li><p>Meter make-up and blowdown to track cycles and spot leaks or overflows.</p></li><li><p>Keep drift eliminators in place and in good condition.</p></li><li><p>Use side-stream filtration in dusty locations to keep suspended solids out of fill and exchangers.</p></li><li><p>Coordinate biocide treatment with Legionella control, as described in <a href="https://www.btc-ksa.com/Knowledge-Hub/post/legionella-control-cooling-towers-saudi-arabia">Legionella control in cooling towers</a>.</p></li></ul><h2>Reducing water use further</h2><p>Where water is very scarce, closed-circuit coolers that can run dry in cooler months, adiabatic coolers or hybrid systems cut water use further; see <a href="https://www.btc-ksa.com/Knowledge-Hub/post/adiabatic-coolers-water-saving-saudi-arabia">adiabatic coolers</a> and <a href="https://www.btc-ksa.com/Knowledge-Hub/post/cooling-tower-performance-loss-recovery-saudi-arabia">why cooling towers lose capacity</a>.</p><h2>Baltimore Aircoil from BTGC</h2><p>Baltimore Aircoil Company builds open and closed-circuit cooling towers, evaporative condensers and adiabatic coolers. BTGC is the <a href="https://www.btc-ksa.com/baltimore-aircoil-saudi-arabia">BAC partner in Saudi Arabia</a> for new equipment, spare parts and refurbishment. See the <a href="https://www.btc-ksa.com/process-separation">process and thermal</a> page.</p><h2>Questions buyers ask</h2><p><strong>How many cycles can our tower run?</strong> It depends on the make-up water chemistry, the treatment programme and the system materials; a water treatment specialist sets the limit from water analysis.</p><p><strong>Can blowdown be reused?</strong> Sometimes, for example for irrigation or other non-potable uses, if its quality meets local requirements.</p><p><strong>Does tower design affect water use?</strong> Evaporation is set by the heat load, but drift, splash-out and the option of dry operation depend on the design.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Mon, 16 Nov 2026 11:17:06 +0300</pubDate></item><item><title><![CDATA[Legionella Control in Cooling Towers in Saudi Arabia]]></title><link>https://www.btc-ksa.com/Knowledge-Hub/post/legionella-control-cooling-towers-saudi-arabia</link><description><![CDATA[<img align="left" hspace="5" src="https://www.btc-ksa.com/knowledge-hub/bac-cooling-towers-rooftop-installation.webp"/>Why cooling towers can grow Legionella in hot climates, and the design, water treatment and maintenance steps that control it. BAC cooling towers and service from BTGC.]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_dPLpdAxmTZ2pzHKE2DIRIQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_bLUHShbjR360zVcn66ZvMQ" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_3FUU0vvASfq0IhuMzrFvkQ" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_lvaaxB-bx_VPhF-dthH4AA" data-element-type="codeSnippet" class="zpelement zpelem-codesnippet "><div class="zpsnippet-container"><p class="btgc-byline" style="margin:0 0 14px;color:rgb(74, 85, 104);font-size:14px;">By <strong>BTGC Engineering Team</strong> · Business Tribune Global Company, Saudi Arabia</p><blockquote style="background:rgb(238, 244, 251);border-left:4px solid rgb(21, 101, 192);padding:14px 18px;margin:0 0 18px;border-radius:6px;"><p><strong>In short:</strong> cooling towers create warm, wet conditions where Legionella bacteria can grow and spread in drift. Hot climates make control more important, not less. Design details, water treatment, regular cleaning and a written risk assessment keep the risk low. BTGC supplies Baltimore Aircoil cooling towers and supports owners with inspection and refurbishment.</p></blockquote><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/bac-cooling-towers-rooftop-installation.webp" alt="BAC cooling tower installation on a plant roof" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><p>Legionella bacteria live in water between about 20 and 45 &deg;C and multiply fastest near body temperature, which is exactly the range of many cooling tower basins in the Kingdom. People are infected by breathing fine water droplets, so towers near air intakes, offices or public areas need particular care. Good practice is set out in guidance such as ASHRAE 188 and similar international codes.</p><h2>Where the risk comes from</h2><table style="width:100%;border-collapse:collapse;margin:16px 0 24px;"><thead><tr><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Factor</th><th style="text-align:left;padding:8px 10px;border-bottom:2px solid rgb(21, 101, 192);background:rgb(238, 244, 251);">Why it matters</th></tr></thead><tbody><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Stagnant water</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Dead legs, idle standby towers and low-flow basins let bacteria grow</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Biofilm and sludge</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Protect bacteria from biocide</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Drift</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Carries droplets away from the tower</td></tr><tr><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Poor water treatment</td><td style="padding:8px 10px;border-bottom:1px solid rgb(227, 232, 238);vertical-align:top;">Lets scale, corrosion and biofouling build up</td></tr></tbody></table><h2>A control programme that works</h2><ul><li><p><strong>Risk assessment and written plan</strong> naming who does what and how often.</p></li><li><p><strong>Continuous water treatment</strong> with biocide, scale and corrosion control, and monitoring of dosing.</p></li><li><p><strong>Routine testing</strong> for total bacteria and periodic Legionella sampling.</p></li><li><p><strong>Cleaning and disinfection</strong> of basins and fill at set intervals and after any positive result.</p></li><li><p><strong>Mechanical upkeep</strong>: effective drift eliminators, clean fill, no dead legs, covered basins.</p></li></ul><figure style="margin:24px 0;"><img loading="lazy" src="https://www.btc-ksa.com/knowledge-hub/bac-closed-circuit-cooling-tower.webp" alt="BAC closed-circuit cooling tower" style="max-width:100%;border-radius:10px;box-shadow:0 12px 30px rgba(0, 0, 0, 0.18);"></figure><h2>Design choices that reduce risk</h2><p>Closed-circuit coolers keep the process fluid out of contact with air, and <a href="https://www.btc-ksa.com/Knowledge-Hub/post/adiabatic-coolers-water-saving-saudi-arabia">adiabatic coolers</a> use far less recirculating water, which reduces the risk further. Where open towers are needed, high-efficiency drift eliminators, sloped and accessible basins and materials that resist biofilm help. See also <a href="https://www.btc-ksa.com/Knowledge-Hub/post/closed-circuit-cooling-towers-saudi-arabia">closed-circuit cooling towers</a>.</p><h2>Baltimore Aircoil from BTGC</h2><p>Baltimore Aircoil Company builds open and closed-circuit cooling towers, evaporative condensers and adiabatic coolers. BTGC is the <a href="https://www.btc-ksa.com/baltimore-aircoil-saudi-arabia">BAC partner in Saudi Arabia</a> for new equipment, spare parts and refurbishment. See the <a href="https://www.btc-ksa.com/process-separation">process and thermal</a> page.</p><h2>Questions buyers ask</h2><p><strong>How often should a cooling tower be cleaned?</strong> At least twice a year in most programmes, and after any positive Legionella result.</p><p><strong>Do closed-circuit coolers need a Legionella plan?</strong> Yes, because the spray water is still open to air, but the risk is lower.</p><p><strong>Can old towers be upgraded?</strong> Often, with new drift eliminators, fill and basin modifications; BTGC surveys the tower first.</p><h2>Contact BTGC</h2><p>Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. <a href="https://www.btc-ksa.com/contact#quote">Request a quote</a>.</p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Mon, 16 Nov 2026 09:11:45 +0300</pubDate></item></channel></rss>