Feedwater Check Valves: Swing, Tilting Disc or Lift?

16.11.26 09:00 AM

In short: a feedwater check valve has to close fast enough to stop reverse flow when a pump trips, without slamming, and it has to survive years of high-pressure, high-temperature water. Swing, tilting disc and lift check valves behave very differently. BTGC supplies Okano Valve check valves for Saudi power, cogeneration and desalination plants, with inspection and repair in Jubail.

Okano Valve high-pressure valve range

Every boiler feed pump discharge has a check valve, and so does every parallel pump that might back-flow through a stopped unit. In a combined cycle or cogeneration plant those valves see pressures above 150 bar and temperatures near 200 °C, and they are expected to do nothing for years and then close in a fraction of a second.

Three designs compared

TypeStrengthsWatch out for
Swing checkLow pressure drop, simple, good for large sizesSlow closing with long disc travel; can slam on pump trip
Tilting disc checkShort stroke, fast closing, low slam, low pressure dropHigher cost; needs correct sizing to keep the disc fully open
Lift (piston) checkTight sealing, good in small high-pressure linesHigher pressure drop; sensitive to dirt

Why check valves fail

  • Oversizing. A disc that never fully opens flutters in the flow and wears its hinge pin and seat.

  • Slam. When flow reverses before the disc closes, the disc slams shut and sends a pressure surge through the line, as described in the article on non-slam check valves and water hammer.

  • Erosion. High-velocity water and flashing erode seats, especially downstream of control valves.

  • Hard-facing damage. Thermal cycling cracks seat overlays, the same mechanism covered in hard-faced gate valves.

High-pressure valves installed in a power plant

Inspection at outages

Check valves are easy to forget because they have no actuator and no position signal. A simple outage routine catches most problems: open the cover, check the disc, hinge pin and bushing wear, inspect seat hard-facing, blue the seat contact and replace the cover gasket. Valves with pressure seal bonnets need the right tools and new seal rings; the BTGC service center in Jubail handles both bolted and pressure seal designs.

Okano Valve from BTGC

Okano Valve Mfg. Co. builds forged and cast gate, globe and check valves for high-pressure and high-temperature service in power plants. BTGC is the Okano Valve partner in Saudi Arabia for new valves and spares. See the flow control and valves page and the power and utilities sector page.

Questions buyers ask

Can a swing check be replaced by a tilting disc check in the same space? Often yes if the face-to-face dimension and end connections match; BTGC checks the line data before quoting.

How do we know if a check valve is slamming? A loud bang on pump trip, pipe movement or damaged supports are the usual signs; a pressure transient recording confirms it.

Do you repair pressure seal check valves? Yes, at the Jubail service center, including seat restoration and new pressure seal rings.

Contact the BTGC valve team

Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. Request a quote.