In short: an oil leak from a reducer is more than a mess: it means oil is being lost, dirt can get in and a seal or breather has a problem. Most leaks come from worn or damaged shaft seals, blocked breathers that let pressure build as the unit heats, overfilling, or the wrong mounting position oil level. Fix the cause, not just the seal. BTGC supplies Sumitomo Cyclo drives, gearmotors and parts.

Gearmotors on conveyors, clarifiers, mixers and screens in Saudi plants run hot in summer, which makes leaks more common.
Common causes
| Cause | Signs |
|---|---|
| Worn shaft seal | Oil at the output or input shaft; grooved shaft surface |
| Blocked or missing breather | Leaks appear when the unit is hot; pressure at the fill plug |
| Overfilling | Oil pushed out of seals and breather |
| Wrong oil level for mounting position | Units mounted differently from the order |
| Loose covers or plugs | Oil at joints and drain plugs |
Fixing leaks properly
Check that the oil level matches the mounting position on the nameplate.
Clean or replace the breather, and move it to the highest point if the unit was remounted.
Replace seals with the correct size and material, and repair or sleeve a grooved shaft.
Use the oil grade and viscosity recommended for the ambient.
For grease-lubricated Cyclo units, follow the regreasing amounts; over-greasing also causes leaks.

Preventing repeat leaks
Protect seals from dust with shields or V-rings in dirty areas.
Avoid pressure washing directly at seals.
Check temperatures in summer; a unit running very hot may be overloaded; see gearmotor sizing.
Record leaks and fixes to spot units that keep failing.
Sumitomo Drive from BTGC
Sumitomo Drive Technologies makes Cyclo drives and gearmotors. BTGC supplies Sumitomo Drive in Saudi Arabia with replacement units and parts. See also gearmotors for water treatment and the lubrication and reliability page.
Questions buyers ask
Can I just add sealant to stop a leak? No; find and fix the cause, or the leak will return.
Why does a reducer leak only when hot? Usually a blocked breather or overfilling, as air and oil expand with heat.
Does BTGC supply seal kits? Yes, for Sumitomo units based on the nameplate.
Contact BTGC
Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. Request a quote.