In short: bitumen, asphalt, vacuum residue and heavy fuel oils are almost solid at ambient temperature and must be kept hot, often well above 150 degC, to flow. Valves are the coldest and most complex points in these lines, so they need heating jackets fed with steam or hot oil. A well-designed jacketed valve keeps the body, bonnet and seats evenly hot, so the product never sets inside and the valve can operate when needed. BTGC supplies Xomox jacketed plug valves and other valves for heated services.

Refineries, bitumen plants, terminals and power plants burning heavy fuel in the Kingdom run long heated lines. Valves that freeze up stop loading and transfers and are hard to free safely.
Jacket options
| Option | Use |
|---|---|
| Full jacket | Body and bonnet enclosed, even heating for difficult products |
| Partial jacket or bolt-on heating | Lighter duties or retrofits |
| Steam heating | Common where plant steam is available |
| Hot oil heating | Higher temperatures and more even heat |
| Electric tracing | Small lines and remote areas |
Design points
Make sure the jacket covers the seat and plug or ball areas, not just the body ends.
Use jacketed flanges or heated spool pieces to avoid cold spots at connections.
Size jacket connections and steam traps so condensate drains freely.
Allow for thermal expansion between jacket and valve body.
Plug valves suit sticky products because the plug wipes the sealing surfaces when it turns.

Operating tips
Warm valves fully before operating them after a shutdown.
Flush lines with lighter oil before long shutdowns where procedures allow.
Check steam traps and hot oil flow regularly; a failed trap creates a cold valve.
Keep insulation complete and dry around jacketed valves.
Do not force a seized valve; reheat it and follow safe procedures.
Xomox from BTGC
Xomox, part of Crane ChemPharma and Energy, supplies sleeved and jacketed plug valves, lined valves and high-performance butterfly valves. BTGC is the Xomox partner in Saudi Arabia. See also molten sulphur valves, delayed coker valves and the oil and gas sector page.
Questions buyers ask
Why do bitumen valves seize? The product cools and solidifies inside the valve when heating is lost or uneven.
Steam or hot oil jackets? Steam is common where available; hot oil gives higher, more even temperatures.
Does BTGC supply jacketed valves? Yes, Xomox jacketed plug valves for heated services.
Contact the BTGC valve team
Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. Request a quote.