In short: a performance test proves that a centrifugal pump delivers the head, flow and efficiency promised on its data sheet before it ships. Tests follow API 610 for refinery and petrochemical pumps or an ISO 9906 grade for general pumps, with set tolerances on head, power and efficiency. NPSH, mechanical run and other tests can be added. Deciding which tests to witness is part of buying the pump. BTGC supplies Akay API 610 and chemical process pumps.

Saudi oil, gas and petrochemical owners usually ask for factory tests and an inspection plan on critical pumps.
Typical tests
| Test | Purpose |
|---|---|
| Hydrostatic test | Proves casing integrity at test pressure |
| Performance test | Head, flow, power and efficiency at several points from shut-off to beyond rated flow |
| NPSH test | Confirms required NPSH, usually defined by a 3% head drop |
| Mechanical run test | Checks vibration, bearing temperatures and leaks over a set time |
| Complete unit or string test | Pump tested with its own driver, seal system or gear, when specified |
Tolerances and acceptance
The test standard sets tolerance bands at the rated point, so agree in the order whether API 610 or an ISO 9906 grade applies.
Results are corrected to rated speed and specific gravity; check how corrections were made.
API 610 vibration limits depend on pump type and are checked across the allowable operating region.
Bearing temperatures must settle within limits during the run.

Planning inspection
Mark each test as witness, observe or document review in the inspection and test plan.
Ask for calibration certificates of the test instruments.
Compare the test curve with the data sheet and with the system curve the plant needs.
Review the NPSH margin; see NPSH and cavitation.
Keep the results for future reliability work and rerates.
Akay from BTGC
Akay supplies API 610 and chemical process pumps with spare parts. BTGC supplies Akay pumps in Saudi Arabia and coordinates data sheets, inspection plans and documents. See also API 610 pump types, the rotating equipment page and the oil and gas sector.
Questions buyers ask
Is every API 610 pump tested? API 610 calls for hydrostatic and performance tests; NPSH and other tests are often specified as options.
What is NPSH3? The NPSH at which the pump head falls by 3%, used to define required NPSH.
Can BTGC arrange witness testing? BTGC coordinates inspection dates and documents with the manufacturer.
Contact BTGC
Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. Request a quote.