Shaft Grounding Brushes: Protecting Bearings from Shaft Currents

18.11.26 02:22 PM

In short: voltage on a motor or generator shaft can discharge through the bearings, burning tiny pits in the races and leaving the frosted or fluted pattern that ends in noise and failure. Variable speed drives, magnetic asymmetry and static build-up all cause it. A shaft grounding brush gives the current an easier path to earth, and insulated bearings block the path through the bearing. BTGC supplies Best Carbon grounding brushes and fits them at the Jubail service center.

Carbon brushes, holders and slip ring parts

Motors on VFDs, turbine generators and large fans in Saudi plants all need protection from shaft currents.

Sources of shaft voltage

SourceTypical machines
Common-mode voltage from VFDsMotors on variable speed drives, especially larger and MV motors
Magnetic asymmetryLarge motors and generators, causing circulating currents
Electrostatic chargeMachines driving belts, fans or turbines in dry air
Excitation systemsGenerators with static excitation

Protection methods

  • Shaft grounding brush on the drive end or non-drive end to drain current to the frame.

  • Insulated bearing or insulated housing at the opposite end to break the circulating path.

  • Ceramic (hybrid) bearings in some motor designs.

  • Good earthing and symmetrical, shielded motor cables on VFD drives; see VFD bearing currents in MV motors.

High voltage motor in a plant

Keeping grounding brushes working

  • Choose a brush grade suited to the shaft speed and current; see carbon brush grades.

  • Check brush length, spring pressure and contact surface at each inspection.

  • Keep the contact track clean and free of oil and dust.

  • Measure shaft voltage periodically to confirm the system works.

  • Check bearing insulation resistance during motor overhauls.

Best Carbon from BTGC

Best Carbon supplies carbon brushes, brush holders, slip rings and grounding devices. BTGC supplies Best Carbon in Saudi Arabia and fits these parts during motor and generator service at the BTGC Jubail service center. See also the electrical and power systems page.

Questions buyers ask

How do I know bearing currents are the problem? Fluting or frosted marks on the races and a rise in bearing noise, often on VFD-fed motors.

Is one grounding brush enough? Often with an insulated bearing at the other end; the design depends on the machine.

Can BTGC retrofit grounding brushes? Yes, during motor service at the Jubail workshop.

Contact the BTGC power division

Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. Request a quote.