Compressor Anti-Surge Valves in Gas Plants: Speed, Capacity and Noise

17.11.26 12:34 PM

In short: centrifugal compressors surge when flow falls too low for the pressure ratio: flow reverses through the machine, shaking the rotor, bearings and seals. The anti-surge control valve recycles gas from discharge back to suction to keep the compressor away from surge. It must open very fast, pass a large flow at high pressure drop without excessive noise, and position accurately so normal recycle does not waste energy. Choosing and testing it correctly is central to compressor protection. BTGC supplies KOSO severe service and anti-surge control valves.

KOSO severe service control valves

Gas plants, gas-oil separation plants, refineries and petrochemical complexes in the Kingdom run many large centrifugal compressors for gas gathering, export, refrigeration and recycle gas. A single surge event can damage seals and bearings; repeated surge can destroy a compressor.

What the anti-surge valve must do

  • Open fully within a very short time, often one to two seconds, when the controller detects approach to surge.

  • Pass the full recycle flow needed at the worst case, typically at start-up or emergency shutdown.

  • Throttle smoothly and accurately during normal recycle control.

  • Handle a high pressure drop with acceptable noise and vibration.

  • Fail open on loss of air or signal.

Design features

FeaturePurpose
Low-noise, multi-stage trimKeeps noise and pipe vibration within limits at high pressure drop; see noise in control valves
High-capacity bodyLarge Cv for full recycle flow
Fast actuator with boosters and quick exhaust valvesAchieves short opening times on large actuators
Accurate digital positionerFine control during normal operation and diagnostics
Spring-return fail-open actuatorOpens on loss of supply for compressor safety
Gas gathering and compression facility

Sizing and testing

  • Size from compressor performance maps, using all operating cases, start-up and emergency shutdown, not only the design point.

  • Check the full recycle loop: cooler, piping volume and check valve affect how quickly surge can be prevented.

  • Measure stroke times in both directions at commissioning and after maintenance.

  • Test step response and overshoot with the anti-surge controller.

  • Trend positioner diagnostics to spot friction and air supply problems early.

KOSO from BTGC

Nihon KOSO makes severe service control valves, anti-surge valves, high-performance butterfly valves, actuators and positioners. BTGC is the KOSO partner in Saudi Arabia, with valve testing and repair at the Jubail service center. See also turbo compressors, control valve sizing and the oil and gas sector page.

Questions buyers ask

Can a standard globe valve be used for anti-surge? Only if it meets the speed, capacity and noise requirements; many standard valves do not.

Why does the anti-surge valve need to be so fast? Surge can develop within a fraction of a second after a trip; the valve must open before flow collapses.

Does BTGC test anti-surge valves? Yes, including stroke time and response tests at the Jubail service center.

Contact the BTGC valve team

Email valves@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. Request a quote.