In short: instrumentation cables carry the small signals from transmitters, analysers and switches to control and safety systems, while control cables carry commands to valves, motors and alarms. Noise from power cables and drives can corrupt signals, fire can destroy cables that safety systems depend on, and hazardous areas add their own rules. The right construction, screening, armour, fire performance and routing protect signal quality and safety. BTGC supplies Bahra Electric control and instrumentation cables made in the Kingdom.

Refineries, gas plants, petrochemical complexes and power stations in the Kingdom use thousands of kilometres of control and instrumentation cable. Signal problems and cable failures are often hard to trace.
Construction choices
| Element | Options |
|---|---|
| Conductors | Twisted pairs or triads for analogue signals; multicore for control |
| Screening | Individual and overall screens to reduce electrical noise |
| Armour | Steel wire or braid for mechanical protection in buried and exposed runs |
| Sheath | PVC, LSZH or other materials depending on fire and environmental needs |
| Fire performance | Flame-retardant or fire-resistant cables for safety circuits that must keep working in a fire |
Avoiding signal problems
Separate instrument cables from power and drive cables in trays and routes.
Earth screens at one end, usually the control room, unless the system design says otherwise.
Use twisted pairs for analogue signals to cancel noise.
Choose suitable cables for fieldbus and data networks.
Keep junction boxes sealed against dust and moisture.

Hazardous areas and safety circuits
Follow the area classification and cable rules for intrinsically safe and other protection methods.
Use blue-sheathed or clearly identified cables for intrinsically safe circuits where required.
Use fire-resistant cables for emergency shutdown and fire and gas circuits where specified.
Use certified cable glands matched to the cable type.
Record cable schedules and test results for future maintenance.
Bahra Electric from BTGC
Bahra Electric is a Saudi manufacturer of power, control and instrumentation cables and busways. BTGC is the Bahra Electric partner for plants and projects. See also medium voltage cables, busways and the electrical power systems page.
Questions buyers ask
Why use individually screened pairs? They reduce crosstalk and noise between signals in the same cable.
Where are fire-resistant cables needed? For circuits that must keep working during a fire, such as some shutdown and fire and gas systems.
Does BTGC supply locally made instrumentation cables? Yes, through Bahra Electric.
Contact the BTGC power division
Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. Request a quote.