In short: oil-immersed transformers are the standard for outdoor substations and higher ratings: they are efficient, tolerate overloads and cost less. Dry-type transformers, usually cast resin, avoid oil, so they suit buildings, basements, hospitals, malls and industrial rooms where fire safety matters, but they need clean, ventilated rooms. The right choice depends on location, fire rules, rating, losses and how the transformer will be loaded in Saudi heat. BTGC supplies transformers from Arabian Transformers Company.

New cities, giga-projects, malls, data centres and plants in the Kingdom use both types. Picking the wrong one adds cost or creates fire, cooling or reliability problems.
Side-by-side comparison
| Factor | Dry-type (cast resin) | Oil-immersed |
|---|---|---|
| Fire risk | Low, no oil | Needs fire separation and oil containment |
| Location | Indoors, close to loads | Mostly outdoors or in vaults |
| Ratings | Mainly distribution sizes | Distribution to large power ratings |
| Overload capacity | Lower | Higher thanks to oil thermal mass |
| Cost | Higher for the same rating | Lower |
| Maintenance | Cleaning, ventilation and connection checks | Oil testing, leaks, cooling and accessories |
Questions to ask
Is the transformer inside a building or near people, where fire rules favour dry-type?
What enclosure and ventilation will keep a dry-type cool in summer?
Will dust or condensation reach the windings?
What loading and overload profile is expected; see loading in high ambient?
Would an oil-immersed unit with less flammable ester fluid meet the fire requirements?

Maintenance differences
Dry-type: keep windings clean, check fans and temperature monitors, and inspect connections with thermography.
Oil-immersed: test oil regularly, check for leaks and keep radiators clean; see oil testing and DGA.
Both: check protection devices, earthing and loading records.
Arabian Transformers from BTGC
Arabian Transformers Company (ATC) manufactures distribution and power transformers, compact substations and package units in the Kingdom. BTGC is the ATC partner in Saudi Arabia. See also distribution transformers for Saudi conditions, the electrical power systems page and the power and utilities sector page.
Questions buyers ask
Are dry-type transformers more expensive? Usually yes for the same rating, but they can save on fire protection and civil works.
Can dry-type transformers be installed outdoors? Only in suitable enclosures; they are mainly designed for indoor use.
Does BTGC supply both types? Yes, through Arabian Transformers Company.
Contact the BTGC power division
Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. Request a quote.