Condensation in Electrical Enclosures: Heaters, Hygrostats and Sealing

18.11.26 08:22 AM

In short: it seems odd to worry about water in a hot country, but condensation is a common cause of panel failures in the Kingdom. Coastal sites such as Jubail, Dammam and Yanbu have very humid air, desert nights cool panels quickly, and over-cooled air-conditioned panels drop below the dew point when doors open. Water then forms on terminals and electronics, causing corrosion, tracking and trips. Small heaters controlled by hygrostats or thermostats, good sealing and sensible cooling set points prevent it. BTGC supplies Pfannenberg enclosure heaters, controls and cooling units.

Pfannenberg enclosure climate control

Outdoor marshalling cabinets, drive panels, telecom shelters, pump station panels and switchgear in coastal and desert sites are all at risk.

When condensation forms

SituationWhy
Humid coastal nightsPanel surfaces cool below the dew point of the air
Large day and night swingsAir inside cools and releases moisture
Over-cooled panelsCooling units set too low create cold surfaces
Doors opened in humid weatherWarm, wet air meets cold equipment
Wash-down and rainWater enters through poor seals and glands

Prevention measures

  • Install anti-condensation heaters sized for the enclosure volume.

  • Control heaters with hygrostats or thermostats so they run only when needed.

  • Seal doors, cable glands and unused openings.

  • Set cooling units to a reasonable temperature, often around 35 degC, not as low as possible; see enclosure cooling.

  • Drain condensate from cooling units away from the panel.

Outdoor industrial facility

Inspection tips

  • Look for corrosion, white deposits and tracking marks on terminals.

  • Check heater operation and control settings.

  • Inspect door gaskets and glands for damage.

  • Use humidity loggers in problem panels to understand the pattern.

  • Record faults linked to humid seasons.

Pfannenberg from BTGC

Pfannenberg of Germany makes enclosure cooling units, heaters, filter fans, process chillers and signalling devices. BTGC is the Pfannenberg partner in Saudi Arabia. See also signalling devices, IP ratings and the electrical power systems page.

Questions buyers ask

Why do panels need heaters in a hot country? To keep internal surfaces above the dew point at night and in humid weather.

Should panel cooling be set as low as possible? No, over-cooling creates cold surfaces and condensation.

Does BTGC supply enclosure heaters? Yes, Pfannenberg heaters, hygrostats and thermostats.

Contact the BTGC power division

Email power@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. Request a quote.