Gear Unit Lubrication Systems: Splash, Forced Feed, Coolers and Breathers

18.11.26 08:19 AM

In short: industrial gear units are lubricated either by splash, where gears dip in an oil bath, or by forced feed, where a pump sprays oil onto gears and bearings through filters and coolers. Oil temperature is the main limit on gear unit capacity in the Kingdom, so fans, cooling coils or separate oil coolers are often needed. Clean oil and dry, dust-free breathing are just as important. BTGC supplies Hansen industrial gear units and their lubrication options.

Industrial gears and bearings

Conveyors, mills, crushers, mixers and cooling towers in the Kingdom run gear units in high ambient temperatures and dust, where overheated or dirty oil is the most common cause of damage.

Splash or forced lubrication

TypeTypical use
SplashModerate speeds and powers, horizontal shafts
Forced feedHigh speeds, high powers, vertical shafts, multiple stages
CombinedSplash for gears with pumped oil to upper bearings

Controlling oil temperature

  • Shaft-mounted fans add cooling air over the housing.

  • Cooling coils in the sump use plant water.

  • Separate oil-air or oil-water coolers serve forced feed systems.

  • Keep housings clean; dust layers act as insulation.

  • Use oils suited to the running temperature; see synthetic gear oils.

Industrial plant

Keeping oil clean and dry

  • Fit desiccant breathers to keep dust and moisture out.

  • Use filters in forced feed systems and change them on condition.

  • Track cleanliness codes; see ISO 4406 cleanliness.

  • Check oil levels at the correct running condition.

  • Use oil analysis to time oil changes; see gear unit condition monitoring.

Hansen from BTGC

Hansen Industrial Transmissions of Belgium, part of the Sumitomo Drive Technologies group, makes industrial gear units for conveyors, mills, mixers and cooling towers. BTGC is the Hansen partner in Saudi Arabia. See also cooling tower gearboxes and the rotating equipment page.

Questions buyers ask

When does a gear unit need forced lubrication? At high speeds and powers, with vertical shafts or where splash cannot reach all bearings.

What oil temperature is too high? It depends on the oil; many mineral gear oils age quickly above about 80 to 90 degC.

Does BTGC supply cooling options for gear units? Yes, Hansen fans, coils and oil cooling systems.

Contact BTGC

Email info@btc-ksa.com or call +966 13 856 0528. Branches: Dammam, Jubail and Yanbu. Request a quote.